Comparative Accuracy of Bowel Ultrasound Versus Magnetic Resonance Enterography in Combination With Colonoscopy in Assessing Crohn's Disease and Guiding Clinical Decision-making

被引:86
|
作者
Allocca, Mariangela [1 ,2 ]
Fiorino, Gionata [1 ,2 ]
Bonifacio, Cristiana [3 ]
Furfaro, Federica [1 ]
Gilardi, Daniela [1 ]
Argollo, Marjorie [4 ]
Peyrin-Biroulet, Laurent [5 ,6 ]
Danese, Silvio [1 ,2 ]
机构
[1] Humanitas Clin & Res Ctr, IBD Ctr, Milan, Italy
[2] Humanitas Univ, Dept Biomed Sci, Via Manzoni 113, I-20089 Milan, Italy
[3] IRCCS Humanitas, Radiol, Milan, Italy
[4] Univ Fed Sao Paulo UNIFESP, Dept Gastroenterol, Sao Paulo, Brazil
[5] Lorraine Univ, Univ Hosp Nancy, Dept Gastroenterol, Nancy, France
[6] Lorraine Univ, Univ Hosp Nancy, INSERM, U954, Nancy, France
来源
JOURNAL OF CROHNS & COLITIS | 2018年 / 12卷 / 11期
关键词
Bowel ultrasound; Crohn's disease; magnetic resonance enterography; colonoscopy; ULTRASONOGRAPHY; DIAGNOSIS; DAMAGE; COMPLICATIONS; TOMOGRAPHY; INFLIXIMAB; MANAGEMENT; SEVERITY; BEHAVIOR; INDEX;
D O I
10.1093/ecco-jcc/jjy093
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: The comparative accuracy of bowel ultrasound [US] versus magnetic resonance enterography [MRE] in combination with colonoscopy [CS] in assessing Crohn's disease [CD] and influencing the decision-making process is unknown. Methods: Consecutive ileo-colonic CD patients seen in a tertiary referral centre were prospectively assessed by MRE, CS, and bowel US, within 1 week. Sensitivity, specificity, accuracy, positive predictive value [PPV], and negative predictive value [NPV] of bowel US in assessing localisation, enhancement [presence of vascularisation at Power Doppler], active disease [presence of ulcers at colonoscopy], strictures, fistulas, and abscesses were calculated using CS + MRE findings together as a reference standard. Two blinded inflammatory bowel disease [IBD] specialists reviewed MRE and bowel US findings and were asked to decide the therapeutic strategy [continue versus change therapy]. Kappa agreement with clinical decision was calculated. Results: Sixty CD patients [36 with endoscopic disease activity, 28 with complications] were enrolled. For localisation, sensitivity, specificity, accuracy, PPV, and NPV of bowel US were 88%, 96%, 91%, 96%, and 85%, respectively; for enhancement, 87%, 92%, 89%, 93%, and 86%; for activity, 92%, 100%, 96%, 100%, and 94%; for strictures, 75%, 86%, 81%, 78%, and 83%; for fistulas, 100%, 98%, 98%, 66%, and 100%; for abscesses, 100%, 96%, 96%, 33%, and 100%. The concordance of management of CD patients based on bowel US or MRE findings, alone, compared with clinical decision, was 0.768 and 0.767, respectively [p < 0.001]. The concordance between bowel US and MRE on management of CD patients was 0.800 [p < 0.001]. Conclusions: Bowel US is very accurate in assessing CD and is a non-invasive, easy-to-use tool to manage CD patients in clinical practice.
引用
收藏
页码:1280 / 1287
页数:8
相关论文
共 50 条
  • [1] Combination of colonoscopy and magnetic resonance enterography is more useful for clinical decision making than colonoscopy alone in patients with complicated Crohn's disease
    Sagami, Shintaro
    Kobayashi, Taku
    Kikkawa, Nao
    Umeda, Satoko
    Nakano, Masaru
    Toyonaga, Takahiko
    Okabayashi, Shinji
    Ozaki, Ryo
    Hibi, Toshifumi
    [J]. PLOS ONE, 2019, 14 (02):
  • [2] COMPARATIVE ACCURACY OF US VERSUS MRI AND COLONOSCOPY IN ASSESSING DISEASE ACTIVITY AND COMPLICATIONS AND INFLUENCING THE DECISION-MAKING PROCESS IN CROHN'S DISEASE
    Allocca, Mariangela
    Fiorino, Gionata
    Bonifacio, Cristiana
    Furfaro, Federica
    Radice, Simona
    Gilardi, Daniela
    Peyrin-Biroulet, Laurent
    Danese, Silvio
    [J]. GASTROENTEROLOGY, 2017, 152 (05) : S66 - S66
  • [3] Usefulness of magnetic resonance enterography in the clinical decision-making process for patients with inflammatory bowel disease
    Ramos Lopez, Laura
    Hernandez Camba, Alejandro
    Rodriguez-Lago, Iago
    Carrillo Palau, Marta
    Cejas Dorta, Luis
    Elorza, Ainara
    Alonso Abreu, Inmaculada
    Vela, Milagros
    Hidalgo, Alba
    Hernandez Alvarez-Builla, Noemi
    Esther Rodriguez, G.
    Rodriguez, Yolanda
    Tardillo, Carlos
    Diaz-Florez, Lucio
    Eiroa, Daniel
    Aduna, Marta
    Garrido, Maria S.
    Larena, Jose A.
    Cabriada, Jose L.
    Quintero Carrion, Enrique
    [J]. GASTROENTEROLOGIA Y HEPATOLOGIA, 2020, 43 (08): : 439 - 445
  • [4] A magnetic resonance enterography index for assessing small bowel Crohn's disease activity
    Zuo, Ying
    Huang, Wei
    Wei, Juan
    Lan, Xing
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (04) : 2128 - 2142
  • [5] Magnetic resonance enterography, small bowel ultrasound and colonoscopy to diagnose and stage Crohn's disease: patient acceptability and perceived burden
    Miles, Anne
    Bhatnagar, Gauraang
    Halligan, Steve
    Gupta, Arun
    Tolan, Damian
    Zealley, Ian
    Taylor, Stuart A.
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (03) : 1083 - 1093
  • [6] Serial magnetic resonance enterography (MRE) directs clinical decision making in children with small bowel and/or perianal Crohn's disease (CD)
    Sauer, Cary G.
    Middleton, Jeremy
    Huang, Clifton
    Kalb, Bobby
    Martin, Diego
    Alazraki, Adina
    Applegate, Kimberly
    Kugathasan, Subra
    [J]. INFLAMMATORY BOWEL DISEASES, 2011, 17 : S55 - S55
  • [7] Magnetic resonance enterography, small bowel ultrasound and colonoscopy to diagnose and stage Crohn’s disease: patient acceptability and perceived burden
    Anne Miles
    Gauraang Bhatnagar
    Steve Halligan
    Arun Gupta
    Damian Tolan
    Ian Zealley
    Stuart A. Taylor
    [J]. European Radiology, 2019, 29 : 1083 - 1093
  • [8] Accuracy of magnetic resonance enterography in the preoperative assessment of patients with Crohn's disease of the small bowel
    Pous-Serrano, S.
    Frasson, M.
    Palasi Gimenez, R.
    Sanchez-Jorda, G.
    Pamies-Guilabert, J.
    Llavador Ros, M.
    Nos Mateu, P.
    Garcia-Granero, E.
    [J]. COLORECTAL DISEASE, 2017, 19 (05) : O126 - O133
  • [9] Accuracy of magnetic resonance enterography for extraluminal complications of Crohn's disease
    Pecoraro, G. M.
    Orlando, A.
    TesE, L.
    Solina, G.
    Di Mitri, R.
    Mocciaro, F.
    Renna, S.
    Cottone, M.
    [J]. JOURNAL OF CROHNS & COLITIS, 2017, 11 : S238 - S239
  • [10] Accuracy of Magnetic Resonance Enterography in Assessing Response to Therapy and Mucosal Healing in Patients With Crohn's Disease
    Ordas, Ingrid
    Rimola, Jordi
    Rodriguez, Sonia
    Paredes, Jose M.
    Martinez-Perez, Maria J.
    Blanc, Esther
    Arevalo, Juan A.
    Aduna, Marta
    Andreu, Montserrat
    Radosevic, Alexander
    Ramirez-Morros, Anna M.
    Pino, Susana
    Gallego, Marta
    Jauregui-Amezaga, Aranzazu
    Ricart, Elena
    Panes, Julian
    [J]. GASTROENTEROLOGY, 2014, 146 (02) : 374 - +