Real-time cardiac MRI with radial acquisition and k-space variant reduced-FOV reconstruction

被引:7
|
作者
Li, Yu Y. [1 ,2 ]
Rashid, Shams [1 ]
Cheng, Yang J. [1 ]
Schapiro, William [1 ]
Gliganic, Kathleen [1 ]
Yamashita, Ann-Marie [1 ]
Tang, John [1 ]
Grgas, Marie [1 ]
Mendez, Michelle [1 ]
Haag, Elizabeth [1 ]
Pang, Jianing [3 ]
Stoeckel, Bernd [3 ]
Leidecker, Christianne [3 ]
Cao, J. Jane [1 ,4 ]
机构
[1] St Francis Hosp, Cardiac Imaging, DeMatteis Ctr Cardiac Res & Educ, Roslyn, NY USA
[2] SUNY Stony Brook, Radiol & Biomed Engn, Stony Brook, NY 11794 USA
[3] Siemens Med Solut USA Inc, Siemens Healthneers, Malvern, PA USA
[4] SUNY Stony Brook, Clin Med, Stony Brook, NY 11794 USA
关键词
Correlation imaging; Correlation function; High-speed MRI; Parallel imaging; Real-time imaging; PARALLEL IMAGING RECONSTRUCTION; DYNAMIC MRI; CINE MRI; GRAPPA; TRAJECTORIES; RESOLUTION; COILS; SENSE; GROG;
D O I
10.1016/j.mri.2018.07.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work aims to demonstrate that radial acquisition with k-space variant reduced-FOV reconstruction can enable real-time cardiac MRI with an affordable computation cost. Due to non-uniform sampling, radial imaging requires k-space variant reconstruction for optimal performance. By converting radial parallel imaging reconstruction into the estimation of correlation functions with a previously-developed correlation imaging framework, Cartesian k-space may be reconstructed point-wisely based on parallel imaging relationship between every Cartesian datum and its neighboring radial samples. Furthermore, reduced-FOV correlation functions may be used to calculate a subset of Cartesian k-space data for image reconstruction within a small region of interest, making it possible to run real-time cardiac MRI with an affordable computation cost. In a stress cardiac test where the subject is imaged during biking with a heart rate of > 100 bpm, this k-space variant reduced-FOV reconstruction is demonstrated in reference to several radial imaging techniques including gridding, GROG and SPIRiT. It is found that the k-space variant reconstruction outperforms gridding, GROG and SPIRIT in real-time imaging. The computation cost of reduced-FOV reconstruction is similar to 2 times higher than that of GROG. The presented work provides a practical solution to real-time cardiac MRI with radial acquisition and k-space variant reduced-FOV reconstruction in clinical settings.
引用
收藏
页码:98 / 104
页数:7
相关论文
共 50 条
  • [1] Segmented k-space and real-time cardiac cine MR imaging with radial trajectories
    Shankaranarayanan, A
    Simonetti, OP
    Laub, G
    Lewin, JS
    Duerk, JL
    [J]. RADIOLOGY, 2001, 221 (03) : 827 - 836
  • [2] Sliding window reduced FOV reconstruction for real-time cardiac imaging
    Metze, Patrick
    Li, Hao
    Speidel, Tobias
    Buckert, Dominik
    Rottbauer, Wolfgang
    Rasche, Volker
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2020, 30 (03): : 236 - 244
  • [3] Real-time cardiac MRI using an undersampled spiral k-space trajectory and a reconstruction based on a variational network
    Kleineisel, Jonas
    Heidenreich, Julius F.
    Eirich, Philipp
    Petri, Nils
    Koestler, Herbert
    Petritsch, Bernhard
    Bley, Thorsten A.
    Wech, Tobias
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (05) : 2167 - 2178
  • [4] Continuous adaptive radial sampling of k-space from real-time physiologic feedback in MRI
    Francisco Contijoch
    Yuchi Han
    Michael Hansen
    Peter Kellman
    Eugene Gualtieri
    Mark Elliott
    Sebastian Berisha
    James J Pilla
    Robert C Gorman
    Walter R Witschey
    [J]. Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [5] Deep learning-based image reconstruction and motion estimation from undersampled radial k-space for real-time MRI-guided radiotherapy
    Terpstra, Maarten L.
    Maspero, Matteo
    d'Agata, Federico
    Stemkens, Bjorn
    Intven, Martijn P. W.
    Lagendijk, Jan J. W.
    van den Berg, Cornelis A. T.
    Tijssen, Rob H. N.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (15):
  • [6] K-SPACE TRAJECTORY DESIGN FOR REDUCED MRI SCAN TIME
    Sharma, Shubham
    Hari, K. V. S.
    Leus, Geert
    [J]. 2020 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2020, : 1120 - 1124
  • [7] Comparison of ECG-gated rectilinear vs. real-time radial K-space sampling schemes in cine true-FISP cardiac MRI
    Boll, DT
    Merkle, EM
    Seaman, DM
    Gilkeson, RC
    Larson, AP
    Simonetti, OP
    Duerk, JL
    Lewin, JS
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2004, 6 (04) : 793 - 802
  • [8] A Novel Retrospective 3D K-Space Sorting 4D-MRI Technique Using a Radial K-Space Acquisition MRI Sequence
    Liu, Y.
    Subashi, E.
    Yin, F.
    Cai, J.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3898 - 3898
  • [9] MR defecography at 1.5 Tesla with radial real-time imaging at a reduced FOV.
    Tacke, J
    Nolte-Ernsting, C
    Glowinski, A
    Schäffter, T
    Adam, G
    Günther, RW
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 171 (03): : 187 - 191
  • [10] Radial Undersampled MRI Reconstruction Using Deep Learning With Mutual Constraints Between Real and Imaginary Components of K-Space
    Li, Zhaotong
    Li, Sha
    Zhang, Zeru
    Wang, Fei
    Wu, Fengliang
    Gao, Song
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2024, 28 (06) : 3583 - 3596