Fabrication of Textile-Based Dry Electrode and Analysis of Its Surface EMG Signal for Applying Smart Wear

被引:6
|
作者
Kim, Hyelim [1 ]
Rho, Soohyeon [1 ,2 ]
Han, Sora [1 ]
Lim, Daeyoung [1 ]
Jeong, Wonyoung [1 ]
机构
[1] Korea Inst Ind Technol KITECH, Mat & Component Convergence R&D Dept, Ansan 15588, South Korea
[2] Sungkyunkwan Univ, Dept Nano Sci & Technol, Suwon 16419, South Korea
关键词
textile electrode; conductive sheet; embroidery; knitting; surface electromyography;
D O I
10.3390/polym14173641
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Ag/AgCl hydrogel electrodes, which are wet electrodes, are generally used to acquire bio-signals non-invasively. Research concerning dry electrodes is ongoing due to the following limitations of wet electrodes: (1) skin irritation and disease when attached for a long time; (2) poor adhesion due to sweat; and (3) considerable cost due to disposable use. Accordingly, electrodes in film, embroidery, and knit forms were manufactured from conductive sheets and conductive yarns, which are typical textile-type dry electrode materials, using different manufacturing methods and conditions. The prepared electrodes were conducted to measure the morphology, surface resistance, skin-electrode impedance, EMG signal acquisition, and analysis. The conductive sheet type electrode exhibited a similar skin-impedance, noise, and muscle activation signal amplitude to the Ag/AgCl gel electrode due to the excellent adhesion and shape stabilization. Embroidery electrodes were manufactured based on two-dimension lock stitch (Em_LS) and three-dimension moss-stitch (Em_MS). More stable EMG signal acquisition than Em_LS was possible when manufactured with Em_MS. The knit electrode was manufactured with the typical structures of plain, purl, and interlock. Although it was possible to acquire EMG signals, considerable noise was generated as the shape and size of the electrodes were changed due to the stretch characteristics of the knit structure. Finally, the applicability of the textile-type dry electrode was confirmed by combining it with a wearable device. More stable and accurate EMG signal acquirement will be possible through more precise parameter control in the future.
引用
收藏
页数:19
相关论文
共 29 条
  • [1] Characterization of embroidered textile-based electrode for EMG smart wear according to stitch technique
    Kim, Hyelim
    Rho, Soohyeon
    Lim, Daeyoung
    Jeong, Wonyoung
    [J]. FASHION AND TEXTILES, 2023, 10 (01)
  • [2] Characterization of embroidered textile-based electrode for EMG smart wear according to stitch technique
    Hyelim Kim
    Soohyeon Rho
    Daeyoung Lim
    Wonyoung Jeong
    [J]. Fashion and Textiles, 10
  • [3] Design and evaluation of textile-based signal transmission lines and keypads for smart wear
    Cho, Jayoung
    Moon, Jihye
    Sung, Moonsoo
    Jeong, Keesam
    Cho, Gilsoo
    [J]. HUMAN-COMPUTER INTERACTION, PT 2, PROCEEDINGS, 2007, 4551 : 1078 - +
  • [4] EMG Measurement with Textile-Based Electrodes in Different Electrode Sizes and Clothing Pressures for Smart Clothing Design Optimization
    Kim, Siyeon
    Lee, Sojung
    Jeong, Wonyoung
    [J]. POLYMERS, 2020, 12 (10) : 1 - 13
  • [5] Exploring textile-based electrode materials for electromyography smart garments
    Lam, Emily
    Alizadeh-Meghrazi, Milad
    Schlums, Alessandra
    Eskandarian, Ladan
    Mahnam, Amin
    Moineau, Bastien
    Popovic, Milos R.
    [J]. JOURNAL OF REHABILITATION AND ASSISTIVE TECHNOLOGIES ENGINEERING, 2022, 9
  • [6] Gap analysis for the use of smart (textile-based) wearables
    Imran, Aqsa
    Rasheed, Abher
    Arshad, Asma
    [J]. JOURNAL OF THE TEXTILE INSTITUTE, 2022, 114 (03) : 433 - 440
  • [7] Fabrication and Evaluation of Embroidery-Based Electrode for EMG Smart Wear Using Moss Stitch Technique
    Rho, Soohyeon
    Kim, Hyelim
    Lim, Daeyoung
    Jeong, Wonyoung
    [J]. SENSORS, 2023, 23 (21)
  • [8] Durability Design and Construction Enhancement of Textile Electrode Shape on Analysis of Its Surface Electromyography Signal
    Indian Institute of Information Technology Design and Manufacturing Kancheepuram, SMart and Innovative Laboratory for Energy Device, Chennai
    600127, India
    不详
    600127, India
    不详
    600127, India
    不详
    600127, India
    [J]. IEEE Sensors Let, 2024, 10
  • [9] Fabrication and Characterization of Single-Layer Textile-Based Flexible Pressure Sensors for Smart Wearable Electronics Applications
    Choudhry, Nauman Ali
    Shekhar, Ravi
    Khan, Imtiaz Ahmed
    Rasheed, Abher
    Padhye, Rajiv
    Arnold, Lyndon
    Wang, Lijing
    [J]. ADVANCED ENGINEERING MATERIALS, 2023, 25 (11)
  • [10] Development of wearable textile-based moisture sensor for smart diaper applications and examination of its comfort properties
    Tekcin, Meltem
    Kursun, Senem
    [J]. JOURNAL OF THE TEXTILE INSTITUTE, 2024,