Evaluation of accuracy in MS lesion volumetry using realistic lesion phantoms

被引:17
|
作者
Rexilius, J [1 ]
Hahn, HK [1 ]
Schlüter, M [1 ]
Bourquain, H [1 ]
Peitgen, HO [1 ]
机构
[1] MeVis Ctr Med Diagnost Syst & Visualizat, D-28359 Bremen, Germany
关键词
multiple sclerosis; magnetic resonance imaging; partial volume effect; realistic lesion phantom; accurate volumetry;
D O I
10.1016/j.acra.2004.10.059
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Quantitative analysis of such small structures as focal lesions in patients with multiple sclerosis (MS) is an important issue in both diagnosis and therapy monitoring. To reach clinical relevance, the reproducibility and accuracy of a proposed method have to be validated. We propose a framework for the generation of realistic digital phantoms of MS lesions of known volumes and their incorporation into a magnetic resonance (MR) data set of a healthy volunteer. Materials and Methods. We generated 54 data sets from a multispectral brain scan of a healthy volunteer with incorporated MS lesion phantoms. Lesion phantoms were created using different shapes (three), sizes (six), and orientations (three). An evaluation is carried out from a manual analysis of three human experts and two different semiautomatic approaches, with and without explicit modeling of partial volume effects (PVEs). Results. Intraobserver and interobserver studies were performed for the phantom data sets. All experts overestimated the true lesion volume for any phantom data set (median overestimation between 42.9% and 63.2%). Relative error and variability increased with decreasing lesion size. Similar results were obtained for the semiautomatic approach without PVE modeling. Only the approach with explicit PVE modeling was capable of generating accurate volumetric results with low systematic error. Conclusion. The proposed framework based on realistic lesion phantoms incorporated into an MR scan allows for quantitative assessment of the accuracy of manual and automated lesion volumetry. Results clearly show the importance of an improved gold standard in lesion volumetry beyond voxel counting.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 50 条
  • [1] Evaluation of accuracy in MS lesion volumetry using realistic lesion phantoms (vol 12, pg 17, 2005)
    Rexilius, J
    Hahn, HK
    Schlüter, M
    Bourquain, H
    Peitgen, HO
    [J]. ACADEMIC RADIOLOGY, 2005, 12 (04) : 532 - 532
  • [2] Ground truth in MS lesion volumetry - A phantom study
    Rexilius, J
    Hahn, HK
    Bourquain, H
    Peitgen, HO
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 2, 2003, 2879 : 546 - 553
  • [3] Small spheres for lesion detection phantoms
    Turkington, TG
    DeGrado, TR
    Sampson, WH
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2234 - 2237
  • [4] ULTRASOUND FOCAL LESION DETECTABILITY PHANTOMS
    MADSEN, EL
    ZAGZEBSKI, JA
    MACDONALD, MC
    FRANK, GR
    [J]. MEDICAL PHYSICS, 1991, 18 (06) : 1171 - 1180
  • [5] Accuracy of periocular lesion assessment using telemedicine
    Kang, Swan
    Dehabadi, Mohammad
    Sim, Dawn A.
    Thomas, Peter B. M.
    Ewusi, Doris Appiah
    Ezra, Daniel
    [J]. BMJ HEALTH & CARE INFORMATICS, 2021, 28 (01)
  • [6] Axotomy in the MS lesion
    Trapp, BD
    [J]. MULTIPLE SCLEROSIS, 1998, 4 (06): : 501 - 502
  • [7] Novel Techniques for MS Lesion Segmentation Algorithm Evaluation
    Oguz, Ipek
    Carass, Aaron
    Pham, Dzung L.
    Roy, Snehashis
    Subbana, Nagesh
    Calabresi, Peter A.
    Yushkevich, Paul A.
    Shinohara, Russell T.
    Prince, Jerry
    [J]. MULTIPLE SCLEROSIS JOURNAL, 2018, 24 : 72 - 73
  • [8] Association of automated and human observer lesion detecting ability using phantoms
    Kofler, JM
    Lindstrom, MJ
    Kelcz, F
    Madsen, EL
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (03): : 351 - 359
  • [9] Automatic multiple sclerosis brain lesion localisation and volumetry
    Jain, S.
    Smeets, D.
    Ribbens, A.
    Sima, D. M.
    Janssens, K.
    Daams, M.
    Steenwijk, M.
    Vrenken, H.
    Barkhof, F.
    Van Hecke, W.
    [J]. MULTIPLE SCLEROSIS JOURNAL, 2014, 20 : 304 - 305
  • [10] Using crowdsourcing to improve accuracy of pigmented lesion triage
    Olsen, K. C.
    Trister, A.
    Smith, E.
    Domenico, L.
    Leachman, S.
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2016, 136 (05) : S38 - S38