Silicon rapid thermal processing with ripple pyrometry

被引:0
|
作者
Fiory, AT [1 ]
机构
[1] AT&T Bell Labs, Lucent Technol Inc, Murray Hill, NJ 07974 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Thermal processing in silicon integrated circuit fabrication steps for dopant activation, metal silicides, annealing, and oxidation commonly uses single-wafer furnaces that rapidly heat wafers with incandescent infrared lamps. Radiation pyrometers and thermocouple probes are the principle methods of measuring wafer temperature for closed-loop control of rapid thermal processes. The challenge with thermocouples is in dealing with heat from the lamps and non-ideal thermally resistive wafer contact. The challenge with pyrometry is in compensating for the variable emissivity of wafer surfaces and suppressing interference from the lamps. Typical deposited or grown layers of silicon nitride, silicon dioxide, and polycrystalline silicon can produce dramatic changes in emissivity. Layer thicknesses and composition are generally not known with sufficient accuracy, so a method for real time in situ emissivity compensation is required. Accufiber introduced a "ripple technique" to address this issue. The idea is to use two probes, separately sensing radiation from the wafer and the lamps, and extracting AC and quasi-DC parts from each. The AC signals provide a measure of the reflectivity of the wafer, and thence emissivity, as well as the fraction of reflected lamp radiation present in the DC signals. Lucent Technologies introduced a method of using AC lamp ripple to measure wafer temperatures with two radiation probes at a wall in the furnace. One probe views radiation emanating from the wafer through a gap in the lamp array. The other probe has a wide field of view to include lamp radiation. The accuracy of Lucent devices, determined from process results on wafers with various emissivities, is typically in the range of 12 degrees C to 18 degrees C at three standard deviations.
引用
收藏
页码:105 / 115
页数:11
相关论文
共 50 条
  • [1] Temperature monitoring by ripple pyrometry in rapid thermal processing
    Nguyenphu, B
    Oh, M
    Fiory, AT
    [J]. RAPID THERMAL AND INTEGRATED PROCESSING V, 1996, 429 : 291 - 296
  • [2] Pyrometry applications in thermal plasma processing
    Bertrand, P
    Ignatiev, M
    Flamant, G
    Smurov, I
    [J]. VACUUM, 2000, 56 (01) : 71 - 76
  • [3] Novel heaters for thermal processing - (including rapid thermal processing of silicon)
    Sekhar, JA
    Penumella, S
    Fu, M
    [J]. TRANSIENT THERMAL PROCESSING TECHNIQUES IN ELECTRONIC MATERIALS, 1996, : 171 - 175
  • [4] Rapid thermal annealing issues in silicon processing
    Fair, RB
    [J]. TRANSIENT THERMAL PROCESSING TECHNIQUES IN ELECTRONIC MATERIALS, 1996, : 61 - 66
  • [5] Rapid thermal processing for silicon nanoelectronics applications
    Fiory, AT
    [J]. JOM, 2005, 57 (06) : 21 - 26
  • [6] Rapid thermal processing for silicon nanoelectronics applications
    A. T. Fiory
    [J]. JOM, 2005, 57 : 21 - 26
  • [7] EFFECTS OF RAPID THERMAL-PROCESSING ON THERMAL OXIDES OF SILICON
    LEE, SK
    KWONG, DL
    ALVI, NS
    [J]. JOURNAL OF APPLIED PHYSICS, 1986, 60 (09) : 3360 - 3363
  • [8] A rapid thermal processing system for the deposition of silicon carbide layers on silicon
    Montgomery, JH
    Ruddell, FH
    McNeill, DW
    Armstrong, BM
    Gamble, HS
    [J]. INTERNATIONAL JOURNAL OF MATERIALS & PRODUCT TECHNOLOGY, 1996, 11 (1-2): : 166 - 177
  • [9] THE DOPING OF SILICON WITH BORON BY RAPID THERMAL-PROCESSING
    DESOUZA, JP
    HASENACK, CM
    SWART, JE
    [J]. SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 1988, 3 (04) : 277 - 280
  • [10] Rapid thermal processing of silicon wafers with emissivity patterns
    M. Rabus
    A. T. Fiory
    N. M. Ravindra
    P. Frisella
    A. Agarwal
    T. Sorsch
    J. Miner
    E. Ferry
    F. Klemens
    R. Cirelli
    W. Mansfield
    [J]. Journal of Electronic Materials, 2006, 35 : 877 - 891