Energy savings due to building insulation of different thickness

被引:4
|
作者
Orzechowski, Tadeusz [1 ]
Orzechowski, Mateusz [2 ]
机构
[1] Kielce Univ Technol, Al Tysiaclecia PP 7, PL-25314 Kielce, Poland
[2] Stat Off Kielce, Wroblewskiego 2, PL-25369 Kielce, Poland
来源
ENERGY AND FUELS 2016 | 2017年 / 14卷
关键词
D O I
10.1051/e3sconf/20171401030
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the plans of thermo-modernisation of historic buildings, strict requirements on energy performance are often relaxed. Detailed analyses are performed to select thermal upgrading technology that would ensure maximum environmental benefits while preserving the historic value of the building. The analysis of the costs of thermal upgrading with the use of heat-preserving plasters having different insulation properties is made for a coal-fired boiler plant. Optimal and advantageous ranges of insulation materials application are shown in reference to coal savings in boilers with variable and constant efficiency. Climatic conditions and environmental benefits are indicated.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Determination of the energy savings and the optimum insulation thickness in the four different insulated exterior walls
    Ucar, Aynur
    Balo, Figen
    [J]. RENEWABLE ENERGY, 2010, 35 (01) : 88 - 94
  • [2] Determination of optimum insulation thickness, energy savings, and environmental impact for different climatic regions of Turkey
    Cay, Yusuf
    Gurel, Ali Etem
    [J]. ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2013, 32 (02) : 365 - 372
  • [3] ASSESSMENT OF THE ENERGY SAVINGS DUE TO THE BUILDING RETROFIT
    ZMEUREANU, R
    [J]. BUILDING AND ENVIRONMENT, 1990, 25 (02) : 95 - 103
  • [4] Energy and cost savings of optimal thickness for selected insulation materials and air gaps for building walls in tropical climate
    Mahlia, T. M. I.
    Ng, H. M.
    Olofsson, T.
    Andriayana, A.
    Hasanuddin, I.
    [J]. ENERGY EDUCATION SCIENCE AND TECHNOLOGY PART A-ENERGY SCIENCE AND RESEARCH, 2012, 29 (01): : 649 - 662
  • [5] Energy Savings and Optimum Insulation Thickness in External Walls in Palestinian Buildings
    Alsurakji, Ihab
    Abdallah, Ramez
    Assad, Mahmoud
    El-Qanni, Amjad
    [J]. 2021 12TH INTERNATIONAL RENEWABLE ENGINEERING CONFERENCE (IREC 2021), 2021, : 355 - 359
  • [6] THE EFFECT OF INSULATION ON ENERGY SAVINGS AND COSTS FOR THE CURRENT BUILDING INVENTORY IN TURKEY
    Erdem, Serkan
    Onan, Cenk
    Ozkan, Derya B.
    Bedirli, S. Eray
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 7, PTS A-D, 2013, : 745 - 753
  • [7] DETERMINATION OF OPTIMUM INSULATION THICKNESS FOR DIFFERENT BUILDING WALLS IN TURKEY
    Fertelli, Ahmet
    [J]. TRANSACTIONS OF FAMENA, 2013, 37 (02) : 103 - 113
  • [8] Air-conditioning energy consumption due to green roofs with different building thermal insulation
    Jim, C. Y.
    [J]. APPLIED ENERGY, 2014, 128 : 49 - 59
  • [9] Aspects Regarding the Optimal Insulation Thickness, the Cost and Energy Savings for Cold Storage in Romania
    Girip, Alina
    Calota, Razvan
    Ilie, Anica
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (23):
  • [10] Optimal location and thickness of insulation layers for minimizing building energy consumption
    Ibrahim, Mohamad
    Ghaddar, Nesreen
    Ghali, Kamel
    [J]. JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2012, 5 (06) : 384 - 398