Bacterial chemotaxis in static gradients quantified in a biopolymer membrane-integrated microfluidic platform

被引:6
|
作者
Hu, Piao [1 ]
Ly, Khanh L. [2 ]
Pham, Le P. H. [1 ]
Pottash, Alex E. [3 ]
Sheridan, Kathleen [2 ]
Wu, Hsuan-Chen [4 ]
Tsao, Chen-Yu [4 ]
Quan, David [4 ]
Bentley, William E. [3 ,4 ]
Rubloff, Gary W. [5 ]
Sintim, Herman O. [6 ]
Luo, Xiaolong [1 ]
机构
[1] Catholic Univ Amer, Dept Mech Engn, Washington, DC 20064 USA
[2] Catholic Univ Amer, Dept Biomed Engn, Washington, DC 20064 USA
[3] Univ Maryland, Fischell Dept Bioengn, College Pk, MD 20742 USA
[4] Univ Maryland, Inst Biosci & Biotechnol Res, College Pk, MD 20742 USA
[5] Univ Maryland, Dept Mat Sci & Engn, College Pk, MD 20742 USA
[6] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
基金
美国国家科学基金会;
关键词
ASSEMBLED CHITOSAN MEMBRANES; DEVICE; BIOFABRICATION; NANOPARTICLES; GENERATION; CELLS; ASSAY;
D O I
10.1039/d2lc00481j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Chemotaxis is a fundamental bacterial response mechanism to changes in chemical gradients of specific molecules known as chemoattractant or chemorepellent. The advancement of biological platforms for bacterial chemotaxis research is of significant interest for a wide range of biological and environmental studies. Many microfluidic devices have been developed for its study, but challenges still remain that can obscure analysis. For example, cell migration can be compromised by flow-induced shear stress, and bacterial motility can be impaired by nonspecific cell adhesion to microchannels. Also, devices can be complicated, expensive, and hard to assemble. We address these issues with a three-channel microfluidic platform integrated with natural biopolymer membranes that are assembled in situ. This provides several unique attributes. First, a static, steady and robust chemoattractant gradient was generated and maintained. Second, because the assembly incorporates assembly pillars, the assembled membrane arrays connecting nearby pillars can be created longer than the viewing window, enabling a wide 2D area for study. Third, the in situ assembled biopolymer membranes minimize pressure and/or chemiosmotic gradients that could induce flow and obscure chemotaxis study. Finally, nonspecific cell adhesion is avoided by priming the polydimethylsiloxane (PDMS) microchannel surfaces with Pluronic F-127. We demonstrated chemotactic migration of Escherichia coli as well as Pseudomonas aeruginosa under well-controlled easy-to-assemble glucose gradients. We characterized motility using the chemotaxis partition coefficient (CPC) and chemotaxis migration coefficient (CMC) and found our results consistent with other reports. Further, random walk trajectories of individual cells in simple bright field images were conveniently tracked and presented in rose plots. Velocities were calculated, again in agreement with previous literature. We believe the biopolymer membrane-integrated platform represents a facile and convenient system for robust quantitative assessment of cellular motility in response to various chemical cues.
引用
收藏
页码:3203 / 3216
页数:14
相关论文
共 30 条
  • [1] Bacterial Chemotaxis in Linear and Nonlinear Steady Microfluidic Gradients
    Ahmed, Tanvir
    Shimizu, Thomas S.
    Stocker, Roman
    [J]. NANO LETTERS, 2010, 10 (09) : 3379 - 3385
  • [2] Rapid Fabrication of Membrane-Integrated Thermoplastic Elastomer Microfluidic Devices
    McMillan, Alexander H.
    Thomee, Emma K.
    Dellaquila, Alessandra
    Nassman, Hussam
    Segura, Tatiana
    Lesher-Perez, Sasha Cai
    [J]. MICROMACHINES, 2020, 11 (08)
  • [3] A three-channel microfluidic device for generating static linear gradients and its application to the quantitative analysis of bacterial chemotaxis
    Diao, JP
    Young, L
    Kim, S
    Fogarty, EA
    Heilman, SM
    Zhou, P
    Shuler, ML
    Wu, MM
    DeLisa, MP
    [J]. LAB ON A CHIP, 2006, 6 (03) : 381 - 388
  • [4] Membrane-integrated microfluidic device for high-resolution live cell imaging
    Epshteyn, Alla A.
    Maher, Steven
    Taylor, Amy J.
    Holton, Angela B.
    Borenstein, Jeffrey T.
    Cuiffi, Joseph D.
    [J]. BIOMICROFLUIDICS, 2011, 5 (04):
  • [5] Bacterial chemotaxis in chemical gradients created in a flow-free microfluidic device
    Nagy, K.
    Haja, O.
    Kerenyi, A.
    Valkai, S.
    Ormos, P.
    Galajda, P.
    [J]. EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2013, 42 : S50 - S50
  • [6] Nephrocyte-neurocyte interaction and cellular metabolic analysis on membrane-integrated microfluidic device
    Qichen Zhuang
    Shiqi Wang
    Jie Zhang
    Ziyi He
    Haifang Li
    Yuan Ma
    JinMing Lin
    [J]. Science China(Chemistry)., 2016, 59 (02) - 250
  • [7] Nephrocyte-neurocyte interaction and cellular metabolic analysis on membrane-integrated microfluidic device
    Qichen Zhuang
    Shiqi Wang
    Jie Zhang
    Ziyi He
    Haifang Li
    Yuan Ma
    Jin-Ming Lin
    [J]. Science China Chemistry, 2016, (02) : 243 - 250
  • [8] Nephrocyte-neurocyte interaction and cellular metabolic analysis on membrane-integrated microfluidic device
    Qichen Zhuang
    Shiqi Wang
    Jie Zhang
    Ziyi He
    Haifang Li
    Yuan Ma
    Jin-Ming Lin
    [J]. Science China Chemistry, 2016, 59 : 243 - 250
  • [9] Nephrocyte-neurocyte interaction and cellular metabolic analysis on membrane-integrated microfluidic device
    Zhuang, Qichen
    Wang, Shiqi
    Zhang, Jie
    He, Ziyi
    Li, Haifang
    Ma, Yuan
    Lin, Jin-Ming
    [J]. SCIENCE CHINA-CHEMISTRY, 2016, 59 (02) : 243 - 250
  • [10] Flow-Based Microfluidic Device for Quantifying Bacterial Chemotaxis in Stable, Competing Gradients
    Englert, Derek L.
    Manson, Michael D.
    Jayaraman, Arul
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2009, 75 (13) : 4557 - 4564