Three-dimensional dynamic MR digital subtraction angiography using sensitivity encoding for the evaluation of intracranial arteriovenous malformations: A preliminary study

被引:0
|
作者
Gauvrit, JY [1 ]
Leclerc, X
Oppenheim, C
Munier, T
Trystram, D
Rachdi, H
Nataf, F
Pruvo, JP
Meder, JF
机构
[1] Univ Hosp Lille, Roger Salengro Hosp, EA 2691, Dept Neuroradiol, Lille, France
[2] Univ Paris 05, Dept Neuroradiol, Paris, France
[3] Univ Paris 05, Dept Neurosurg, Paris, France
[4] Univ Paris 05, St Anne Hosp, Paris, France
[5] Gen Elect Healthcare Technol, Buc, France
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Our aim was to develop 3D dynamic MR digital subtraction angiography with high temporal resolution without sacrificing spatial resolution by using sensitivity encoding for the evaluation of cerebral arteriovenous malformations. METHODS: Nineteen patients with 19 angiographically proven arteriovenous malformations (16 supratentorial and 3 infratentorial) were assessed by conventional catheter angiography and 3D dynamic MR digital subtraction angiography. A 3D contrast-enhanced gradient-echo sequence with sensitivity encoding based on a parallel imaging technique was performed and acquired 20 dynamic images, repeated 18 times every 1.7 seconds. Three-dimensional dynamic MR digital subtraction angiograms were analyzed independently by two radiologists in a blinded fashion with regard to arteriovenous malformation nidus and venous drainage. Conventional catheter angiography was used as reference. RESULTS: All MR imaging examinations were assessable. Interobserver agreement was excellent for the detection of nidus and for the evaluation of nidus size (kappa = 1 and 0.875, respectively) but moderate for the visualization of the venous drainage (kappa = 0.56). All nidi detected on conventional catheter angiography were clearly depicted on 3D dynamic MR digital subtraction angiography. The evaluation of the size of the nidus by both techniques was similar. On 3D dynamic MR angiograms, veins were correctly analyzed in 17 of 19 arteriovenous malformations. CONCLUSION. Our preliminary study demonstrates that 3D dynamic MR digital subtraction angiography using sensitivity encoding with a high spatial resolution is appropriate for the assessment of arteriovenous malformations.
引用
收藏
页码:1525 / 1531
页数:7
相关论文
共 50 条
  • [1] A Prospective Study Comparing the Three-Dimensional Rotational Angiography and Two-Dimensional Digital Subtraction Angiography in Evaluation of Brain Arteriovenous Malformations
    Pan, Somnath
    Kannath, Santhosh K.
    Singh, Gurpreet
    Rajan, Jayadevan E.
    NEUROLOGY INDIA, 2022, 70 (05) : 1905 - +
  • [2] Brain arteriovenous malformations: Assessment with dynamic MR digital subtraction angiography
    Griffiths, PD
    Hoggard, N
    Warren, DJ
    Wilkinson, ID
    Anderson, B
    Romanowski, CA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (10) : 1892 - 1899
  • [3] Arteriovenous malformations: Assessment by MR digital subtraction angiography
    Griffiths, PD
    Warren, DJ
    Hoggard, N
    Anderson, B
    Romanowski, CA
    Wilkinson, ID
    RADIOLOGY, 2000, 214 (02) : 612 - 612
  • [4] Estimation of the number of feeding arteries of spinal arteriovenous malformations by using three-dimensional digital subtraction angiography
    Takamiya, Soichiro
    Osanai, Toshiya
    Seki, Toshitaka
    Fujima, Noriyuki
    Hida, Kazutoshi
    Asano, Takeshi
    Yamazaki, Kazuyoshi
    Hamauchi, Shuji
    Sasamori, Toru
    Ono, Kota
    Terasaka, Shunsuke
    Houkin, Kiyohiro
    EUROPEAN SPINE JOURNAL, 2019, 28 (04) : 842 - 848
  • [5] MR digital subtraction angiography of cerebral arteriovenous malformations
    Tsuchiya, K
    Katase, S
    Yoshino, A
    Hachiya, J
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (04) : 707 - 711
  • [6] Estimation of the number of feeding arteries of spinal arteriovenous malformations by using three-dimensional digital subtraction angiography
    Soichiro Takamiya
    Toshiya Osanai
    Toshitaka Seki
    Noriyuki Fujima
    Kazutoshi Hida
    Takeshi Asano
    Kazuyoshi Yamazaki
    Shuji Hamauchi
    Toru Sasamori
    Kota Ono
    Shunsuke Terasaka
    Kiyohiro Houkin
    European Spine Journal, 2019, 28 : 842 - 848
  • [7] Evaluation of Cerebral Arteriovenous Malformations Using Image Fusion Combining Three-Dimensional Digital Subtraction Angiography with Magnetic Resonance Imaging
    Suzuki, Hidenori
    Maki, Hiroaki
    Taki, Waro
    TURKISH NEUROSURGERY, 2012, 22 (03) : 341 - 345
  • [8] Preoperative evaluation of intracranial aneurysms: Comparison of three-dimensional digital subtraction angiography and conventional two-dimensional digital subtraction angiography
    Yoon, W
    Seo, J
    Kim, JK
    Kim, T
    Park, J
    Kang, H
    RADIOLOGY, 2002, 225 : 521 - 521
  • [9] Digital Subtraction CT Angiography for Detection of Intracranial Aneurysms: Comparison with Three-dimensional Digital Subtraction Angiography
    Lu, Li
    Zhang, Long Jiang
    Poon, Colin S.
    Wu, Sheng Yong
    Zhou, Chang Sheng
    Luo, Song
    Wang, Mei
    Lu, Guang Ming
    RADIOLOGY, 2012, 262 (02) : 605 - 612
  • [10] Usefulness of three-dimensional phase contrast MR angiography on arteriovenous malformations
    Basant Pant
    Masayuki Sumida
    Kazunori Arita
    Atsushi Tominaga
    Fusao Ikawa
    Kaoru Kurisu
    Neurosurgical Review, 1997, 20 : 171 - 176