Numerical and experimental study of a 4 K modified-solvay cycle cryocooler

被引:0
|
作者
Kurihara, T [1 ]
Okamoto, M [1 ]
Sakitani, K [1 ]
Torii, H [1 ]
Morishita, H [1 ]
机构
[1] Daikin Ind Ltd, Mech Engn Lab, Sakai, Osaka 591, Japan
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
A two-stage 4 K Modified-Solvay cycle cryocooler(1), which is a pneumatically driven Gifford - McMahon cryocooler and will be used for the conduction-cooled low temperature superconducting magnets, has been optimized by numerical and experimental study. After the optimization, the maximum cooling capacity of 36.5 W at 35 K on the first stage and 1.08 W at 4.2 K on the second stage with 6.7 kW input power has been obtained. This is the world's first pneumatically driven G-M cryocooler which has over 1 W cooling capacity at 4.2 K. In this paper, experimental and numerical results of the influence of the valve opening timing and the displacer motion concerning the cooling capacity are described. The experimentally obtained optimum P-V diagram and valve timing are in good agreement with the numerical simulation results. And the reliability tests lover 100 times of cool-down and warm-up cycle, and over 3,000 hours continuous operation) were successfully conducted. It can be expected that this 4 K cryocooler has a high reliability equivalent to the commercial G-M cryocoolers which operate above 10 K on the 2nd stage temperature.
引用
收藏
页码:1791 / 1798
页数:4
相关论文
共 50 条
  • [1] Experimental study of a 4 K pulse tube cryocooler
    Fujimoto, S
    Kurihara, T
    Oodo, T
    Kang, YM
    Numazawa, T
    Matsubara, Y
    CRYOCOOLERS 11, 2001, : 213 - 219
  • [2] Numerical and experimental study of VM type pulse tube cryocooler with multi-bypass operating below 4 K
    Pan, Changzhao
    Wang, Jue
    Luo, Kaiqi
    Chen, Liubiao
    Jin, Hai
    Cui, Wei
    Wang, Junjie
    Zhou, Yuan
    CRYOGENICS, 2019, 98 : 71 - 79
  • [3] Numerical and experimental study on the characteristics of 4 K gas-coupled Stirling-type pulse tube cryocooler
    Chen Liubiao
    Wu Xianlin
    Liu Xuming
    Pan Changzhao
    Zhou Yuan
    Wang Junjie
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 88 : 204 - 210
  • [4] Numerical investigation and experimental development on VM-PT cryocooler operating below 4 K
    Zhang, Tong
    Pan, Changzhao
    Zhou, Yuan
    Wang, Junjie
    CRYOGENICS, 2016, 80 : 138 - 146
  • [5] Experimental performance of a modified Collins cycle cryocooler for in-space applications
    Bunge, C. D.
    Siahvashi, A.
    Hannon, C. L.
    Brisson, J. G.
    ADVANCES IN CRYOGENIC ENGINEERING: PROCEEDINGS OF THE CRYOGENIC ENGINEERING CONFERENCE, CEC 2023, 2024, 1301
  • [6] Experimental Research on the JT Cycle of Hybrid 4.5K JT Cryocooler
    Ma, Yuexue
    Quan, Jia
    Wang, Juan
    Liu, Yanjie
    Li, Jianguo
    Liang, Jingtao
    27TH INTERNATIONAL CRYOGENICS ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2018 (ICEC-ICMC 2018), 2019, 502
  • [7] Experimental and numerical study on an open-cycle Joule-Thomson cryocooler working at liquid nitrogen temperature
    Qiu, Changxu
    Shen, Yunwei
    Miao, Wubing
    Xia, Jiaxu
    Liu, Anzhuo
    Gan, Zhihua
    APPLIED THERMAL ENGINEERING, 2024, 249
  • [8] VERSATILE EXPERIMENTAL LOW-POWER 4-K CRYOCOOLER
    LAMBERT, N
    BARBANERA, S
    ZIMMERMAN, JE
    CRYOGENICS, 1986, 26 (06) : 341 - 345
  • [9] The Numerical Simulation and Experimental Study on a VM Type Pulse Tube Cryocooler
    Dai, Wei (cryodw@mail.ipc.ac.cn), 1600, Science Press (38):
  • [10] Numerical Simulation of the Second Stage Regenerator in a 4K GM Cryocooler
    Xu, Mingyao
    Morie, Takaaki
    ADVANCES IN CRYOGENIC ENGINEERING, 2014, 1573 : 1143 - 1148