Comparison of the response of saline tonometry and an automated gas tonometry device to a change in CO2

被引:5
|
作者
Noone, RB
Bolden, JE
Mythen, MG
Vaslef, SN
机构
[1] Duke Univ, Med Ctr, Dept Surg, Durham, NC 27710 USA
[2] UCL Hosp, Dept Anaesthesia, London, England
关键词
monitoring; physiologic; tonometry; in vitro carbon dioxide; critical care; intensive care unit; splanchnic circulation; gastric mucosa; perfusion; regional;
D O I
10.1097/00003246-200011000-00032
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To examine the speed of response of saline tonometry and an automated gas tonometry system by using standard tonometry catheters, Design: In vitro validation study. Setting: Experimental research laboratory. Interventions: Tonometry catheters were placed in a test chamber designed to simulate the lumen of a hollow viscus and were exposed to a rapid change in CO(2) from 0% to 5% or 10%, Measured CO(2) over time was fit to a mathematical model to determine the response time constant (the time to reach 63% of the final value) for each system. Measurements and Main Results: Response time to a change in CO(2) was significantly faster with the automated gas system than with traditional saline tonometry, The mathematical time constant for a 5% change in CO(2) in a gas environment was 2.8 mins (95% confidence interval, 2.6-3.0 mins) for the gas and 6.3 mins (95% confidence interval, 5.8-7.3 mins) for the saline technique. These times were longer for the CO(2) change in a liquid environment: The time constant was 4.6 mins (95% confidence interval, 4.5-4.7 mins) for the gas system and 7.8 mins (95% confidence interval, 7.15-8.6 mins) for the saline tonometry, There was a significantly lower final equilibration value for the CO(2) measurement with saline tonometry, There was essentially no difference in time constants for each system for a 5% change compared with a 10% CO(2) change, except for a slightly faster time constant for the gas tonometry system with a 5% change in the gas environment (5%: 2.8 mins vs, 10%: 3.3 mins), Conclusions: The automated gas tonometry system has a significantly faster response to a change in CO(2) than conventional saline tonometry.
引用
收藏
页码:3728 / 3733
页数:6
相关论文
共 50 条
  • [1] A comparison of the response of the tonocap and saline tonometry to a change in CO2
    RB Noone
    MG Mythen
    SN Vaslef
    [J]. Critical Care, 1 (Suppl 1):
  • [2] Comparison of gastric air tonometry with standard saline tonometry
    Tzelepis, G
    Kadas, V
    Michalopoulos, A
    Geroulanos, S
    [J]. INTENSIVE CARE MEDICINE, 1996, 22 (11) : 1239 - 1243
  • [3] Gastric tonometry:: in vivo comparison of saline and air tonometry in patients with cardiogenic shock
    Janssens, U
    Graf, J
    Koch, KC
    Hanrath, P
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1998, 81 (05) : 676 - 680
  • [4] Assessment of a new prototype hydrogel CO2 sensor; comparison with air tonometry
    ter Steege R.W.F.
    Herber S.
    Olthuis W.
    Bergveld P.
    van den Berg A.
    Kolkman J.J.
    [J]. Journal of Clinical Monitoring and Computing, 2007, 21 (2) : 83 - 90
  • [5] Comparison of air tonometry with gastric tonometry using saline and other equilibrating fluids: an in vivo and in vitro study
    Mallick, A
    Hartley, G
    Bodenham, A
    Vucevic, M
    [J]. INTENSIVE CARE MEDICINE, 1998, 24 (08) : 777 - 784
  • [6] Comparison of air tonometry with gastric tonometry using saline and other equilibrating fluids: an in vivo and in vitro study
    B. Barry
    A. Mallick
    G. Hartiey
    A. Bodenham
    M. Vucevic
    [J]. Intensive Care Medicine, 1998, 24 : 777 - 784
  • [7] Comparison of Rebound Tonometry, Perkins Applanation Tonometry and Ocular Response Analyser in Mucopolysaccharidosis Patients
    Wasielica-Poslednik, Joanna
    Butsch, Christina
    Lampe, Christina
    Elflein, Heike
    Lamparter, Julia
    Weyer, Veronika
    Pitz, Susanne
    [J]. PLOS ONE, 2015, 10 (08):
  • [8] The effect of hypothermia on calculated values using saline and automated air tonometry
    Chapman, MV
    Woolf, RL
    Bennett-Guerrero, E
    Mythen, MG
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (03) : 304 - 307
  • [9] COMPARISON BETWEEN METHODS OF TONOMETRY - TIME FOR A CHANGE OF APPROACH
    HOLTEDAHL, K
    CHRISTOFFERSEN, T
    FORS, T
    RINGBERG, U
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1993, 77 (11) : 754 - 755
  • [10] Comparison of Dynamic Contour Tonometry with Goldmann Applanation Tonometry following Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK)
    Bochmann, F.
    Kaufmann, C.
    Becht, C.
    Bachmann, L. M.
    Thiel, M. A.
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2009, 226 (04) : 241 - 244