Experimental investigation on minichannel parallel flow condenser performance with R22, R410A and R407C

被引:3
|
作者
Qi, Zhaogang [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, 800,Dongchuan Rd, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
Minichannel; Condenser; Refrigerant; R410A; R407C; HEAT-TRANSFER; PRESSURE-DROP; MICROCHANNEL; REFRIGERATION; PUMP;
D O I
10.1016/j.ijrefrig.2016.07.021
中图分类号
O414.1 [热力学];
学科分类号
摘要
A performance evaluation of minichannel parallel flow (MCPF) condenser in residential/commercial refrigeration system has been carried out in calorimeter room with wind tunnel in this paper. The heat rejection and pressure drop characteristics for heat exchangers were compared using R22, R410A and R407C as working fluids. The experimental results showed that heat rejection of MCPF condenser with R410A was higher than that of R22 and R407C by 15.6 similar to 26.3% and 12.3 similar to 22.7% under full and partial load conditions, respectively. The refrigerant side pressure drop trend of R410A in MCPF condenser was smaller than that of R22 and R407C under the same mass flow rate. (C) 2016 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 50 条
  • [1] Experimental investigation on mass flow characteristics of electronic expansion valves with R22, R410A and R407C
    Chen Liang
    Chen Jiangping
    Liu Jinghui
    Chen Zhijiu
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (04) : 1033 - 1039
  • [2] Experimental investigation of the performance of R22, R407C and R410A in several capillary tubes for air-conditioners
    Kim, SG
    Kim, MS
    Ro, ST
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (05): : 521 - 531
  • [3] Experimental investigation of condensation heat transfer and pressure drop of R22, R410A and R407C in mini-tubes
    Zhang, Hui-Yong
    Li, Jun-Ming
    Liu, Na
    Wang, Bu-Xuan
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (13-14) : 3522 - 3532
  • [4] Experimental investigation of R407C and R410A flow through electronic expansion valve
    Ye Qifang
    Chen Jiangping
    Chen Zhijiu
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (05) : 1624 - 1630
  • [5] A comparative performance study of a direct expansion geothermal evaporator using R410A and R407C as refrigerant alternatives to R22
    Fannou, Jean-Louis Comlan
    Rousseau, Clement
    Lamarche, Louis
    Kajl, Stanislaw
    APPLIED THERMAL ENGINEERING, 2015, 82 : 306 - 317
  • [6] Performance of R407C as an Alternate to R22: A Review
    Kasera, Shailendra
    Bhaduri, Shishir Chandra
    INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016, 2017, 109 : 4 - 10
  • [7] Flow condensation heat transfer coefficients of R22, R134a, R407C, and R410A inside plain and microfin tubes
    Jung, D
    Cho, Y
    Park, K
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (01): : 25 - 32
  • [8] Experimental Study on Pool Boiling Heat Transfer for R22, R407c, and R410a on a Horizontal Tube Bundle With Enhanced Tubes
    Li, Qianxia
    Zhang, Zhengguo
    Gao, Xuenong
    HEAT TRANSFER ENGINEERING, 2011, 32 (11-12) : 943 - 948
  • [9] Artificial neural network models for depicting mass flow rate of R22, R407C and R410A through electronic expansion valves
    Saleh, B.
    Aly, Ayman A.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 63 : 113 - 124
  • [10] R22,R407C和R410A热泵专用涡旋式压缩机研究
    杨晓倩
    高飞
    刘忠赏
    制冷与空调, 2015, (02) : 85 - 88