Bi-enzymatic amperometric biosensor for oxalate

被引:62
|
作者
Perez, EF
Neto, GD
Kubota, LT
机构
[1] UNICAMP, Inst Quim, BR-13083970 Campinas, SP, Brazil
[2] USF, Ctr Ciencias Biol & Saude, Braganca Paulista, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
biosensor for oxalate; carbon paste electrode; oxalate oxidase; horseradish peroxidase;
D O I
10.1016/S0925-4005(00)00637-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a new amperometric biosensor for oxalate utilising two enzymes, oxalate oxidase (OXO) and horseradish peroxidase (HRP), incorporated into carbon paste electrode modified with silica gel coated with titanium oxide containing toluidine blue is described. OXO has been immobilised on silica gel modified with titanium oxide surface using glutaraldehyde for crosslinking. HRP has been immobilised with covalent binding with carbodiimide on graphite powder. The biosensor showed a good performance with a linear response range between 0.1 and 2.0 mmol 1(-1) of oxalate, fit by the equation i = 0.33(+/-0.041) + 2.29(+/-0.04) [oxalate], where i is the current in muA and [oxalate] is the oxalate concentration in mmol 1(-1) with a correlation coefficient of 0.998 for n = 20. The biosensor could be used for 80 determinations when stored in a succinate buffer at pH 3.8 in a refrigerator. The response time was about 0.5 s. The detection limit, considering three times the noise, was 0.09 mmol 1(-1) for oxalate. The time for oxalate determination in spinach samples decreased by 3 days when this biosensor was used, compared to the AOAC method. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 50 条
  • [1] Bi-enzymatic optode detection system for oxalate determination based on a natural source of enzyme
    Sotomayor, MDT
    Raimundo, IM
    Neto, GO
    Kubota, LT
    ANALYTICA CHIMICA ACTA, 2001, 447 (1-2) : 33 - 40
  • [2] A bi-enzymatic whole-cell algal biosensor for monitoring waste water pollutants
    Durrieu, C
    Chouteau, C
    Barthet, L
    Chovelon, JM
    Tran-Minh, C
    ANALYTICAL LETTERS, 2004, 37 (08) : 1589 - 1599
  • [3] Synergic effect studies of the bi-enzymatic system laccase-peroxidase in a voltammetric biosensor for catecholamines
    Leite, OD
    Lupetti, KO
    Fatibello, O
    Vieira, IC
    Barbosa, AD
    TALANTA, 2003, 59 (05) : 889 - 896
  • [4] A novel bi-enzymatic system for lactose conversion
    Lorenzen, Peter Chr.
    Breiter, Judith
    Clawin-Raedecker, Ingrid
    Dau, Alexandra
    INTERNATIONAL JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 2013, 48 (07): : 1396 - 1403
  • [5] Efficient Bi-enzymatic synthesis of aldonic acids
    Tetianec, Lidija
    Bratkovskaja, Irina
    Casaite, Vida
    Gureviciene, Vidute
    Razumiene, Julija
    Stankeviciute, Jonita
    Meskys, Rolandas
    Dagys, Marius
    Laurynenas, Audrius
    GREEN CHEMISTRY, 2022, 24 (12) : 4902 - 4908
  • [6] A bi-enzymatic whole cell conductometric biosensor for heavy metal ions and pesticides detection in water samples
    Chouteau, C
    Dzyadevych, S
    Durrieu, C
    Chovelon, JM
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (02): : 273 - 281
  • [7] Sensitive amperometric oxalate biosensor for food analysis
    Milardovic, S
    Grabaric, Z
    Grabaric, BS
    FOOD TECHNOLOGY AND BIOTECHNOLOGY, 2000, 38 (03) : 203 - 210
  • [8] One-pot construction of mediatorless bi-enzymatic glucose biosensor based on organic-inorganic hybrid
    Manesh, K. M.
    Santhosh, P.
    Uthayakumar, S.
    Gopalan, A. I.
    Lee, K. -P.
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (07): : 1579 - 1586
  • [9] Enzymatic racemization of alcohols and amines: An approach for bi-enzymatic dynamic kinetic resolution
    Musa, Musa M.
    CHIRALITY, 2020, 32 (02) : 147 - 157
  • [10] An Amperometric Oxalate Biosensor Based on Polypropylene Tip Bound Sorghum Oxalate Oxidase
    Yadav, Sandeep
    Devi, Rooma
    Pundir, C. S.
    SENSOR LETTERS, 2011, 9 (05) : 1661 - 1665