Determination of rSpike Protein by Specific Antibodies with Screen-Printed Carbon Electrode Modified by Electrodeposited Gold Nanostructures

被引:30
|
作者
Drobysh, Maryia [1 ,2 ]
Liustrovaite, Viktorija [2 ]
Baradoke, Ausra [1 ]
Viter, Roman [3 ,4 ]
Chen, Chien-Fu [5 ]
Ramanavicius, Arunas [1 ,2 ]
Ramanaviciene, Almira [2 ]
机构
[1] Ctr Phys & Technol Sci, State Res Inst, Sauletekio Ave 3, LT-10257 Vilnius, Lithuania
[2] Vilnius Univ, Fac Chem & Geosci, NanoTechnas Ctr Nanotechnol & Mat Sci, Naugarduko Str 24, LT-03225 Vilnius, Lithuania
[3] Univ Latvia, Inst Atom Phys & Spect, Jelgavas St 3, LV-1004 Riga, Latvia
[4] Sumy State Univ, Ctr Collect Use Res Equipment, 31 Sanatorna St, UA-40000 Sumy, Ukraine
[5] Natl Taiwan Univ, Inst Appl Mech, 1 Sec 4,Roosevelt Rd, Taipei 106, Taiwan
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 08期
关键词
COVID-19; SARS-CoV-2; virus; electrochemical immunosensor; differential pulse voltammetry (DPV); cyclic voltammetry (CV); electrochemical impedance spectroscopy (EIS); self-assembled monolayer (SAM); antigen-antibody complex; spike protein (Spike); gold nanostructures (AuNS); ELECTROCHEMICAL BIOSENSORS; ELECTROCHEMILUMINESCENCE; NANOPARTICLES; IMMUNOSENSOR; DIANHYDRIDE;
D O I
10.3390/bios12080593
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this research, we assessed the applicability of electrochemical sensing techniques for detecting specific antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike proteins in the blood serum of patient samples following coronavirus disease 2019 (COVID-19). Herein, screen-printed carbon electrodes (SPCE) with electrodeposited gold nanostructures (AuNS) were modified with L-Cysteine for further covalent immobilization of recombinant SARS-CoV-2 spike proteins (rSpike). The affinity interactions of the rSpike protein with specific antibodies against this protein (anti-rSpike) were assessed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods. It was revealed that the SPCE electroactive surface area increased from 1.49 +/- 0.02 cm(2) to 1.82 +/- 0.01 cm(2) when AuNS were electrodeposited, and the value of the heterogeneous electron transfer rate constant (k(0)) changed from 6.30 x 10(-5) to 14.56 x 10(-5). The performance of the developed electrochemical immunosensor was evaluated by calculating the limit of detection and limit of quantification, giving values of 0.27 nM and 0.81 nM for CV and 0.14 nM and 0.42 nM for DPV. Furthermore, a specificity test was performed with a solution of antibodies against bovine serum albumin as the control aliquot, which was used to assess nonspecific binding, and this evaluation revealed that the developed rSpike-based sensor exhibits low nonspecific binding towards anti-rSpike antibodies.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Novel Pt nanowires modified screen-printed gold electrode by electrodeposited method
    Zhao, Hongli
    Zhou, Changxiang
    Teng, Yuanjie
    Chen, Chen
    Lan, Minbo
    [J]. APPLIED SURFACE SCIENCE, 2011, 257 (08) : 3793 - 3797
  • [2] Screen-Printed Carbon Electrode Modified with Poly-L-histidine Applied to Gold(III) Determination
    Bergamini, Marcio F.
    Santos, Daniela P.
    Zanoni, Maria Valnice B.
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (01) : 100 - 106
  • [3] Voltammetric determination of doxycycline in feedstock using modified carbon screen-printed electrode
    M. S. Tiwari
    R. G. Thorat
    B. B. Popatkar
    V. V. Borge
    A. K. Kadu
    [J]. Analytical Sciences, 2023, 39 : 1889 - 1899
  • [4] Voltammetric determination of doxycycline in feedstock using modified carbon screen-printed electrode
    Tiwari, M. S.
    Thorat, R. G.
    Popatkar, B. B.
    Borge, V. V.
    Kadu, A. K.
    [J]. ANALYTICAL SCIENCES, 2023, 39 (11) : 1889 - 1899
  • [5] Gold Nanoparticles Decorated on Carbon Nanotube Modified Screen-printed Electrode for Flow Injection Amperometric Determination of Methyldopa
    Upan, Jantima
    Themsirimongkon, Suwaphid
    Saipanya, Surin
    Jakmunee, Jaroon
    [J]. CHIANG MAI JOURNAL OF SCIENCE, 2019, 46 (03): : 537 - 546
  • [6] Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles
    Nahid Shoaie
    Mehdi Forouzandeh
    Kobra Omidfar
    [J]. Microchimica Acta, 2018, 185
  • [7] Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles
    Shoaie, Nahid
    Forouzandeh, Mehdi
    Omidfar, Kobra
    [J]. MICROCHIMICA ACTA, 2018, 185 (04)
  • [8] Activity enhancement of a screen-printed carbon electrode by modification with gold nanoparticles for glucose determination
    Masaru Iwamoto
    Shiho Tokonami
    Hiroshi Shiigi
    Tsutomu Nagaoka
    [J]. Research on Chemical Intermediates, 2009, 35
  • [9] Activity enhancement of a screen-printed carbon electrode by modification with gold nanoparticles for glucose determination
    Iwamoto, Masaru
    Tokonami, Shiho
    Shiigi, Hiroshi
    Nagaoka, Tsutomu
    [J]. RESEARCH ON CHEMICAL INTERMEDIATES, 2009, 35 (8-9) : 919 - 930
  • [10] A microfluidic device based on a screen-printed carbon electrode with electrodeposited gold nanoparticles for the detection of IgG anti-Trypanosoma cruzi antibodies
    Pereira, Sirley V.
    Bertolino, Franco A.
    Fernandez-Baldo, Martin A.
    Messina, German A.
    Salinas, Eloy
    Sanz, Maria I.
    Raba, Julio
    [J]. ANALYST, 2011, 136 (22) : 4745 - 4751