Using the bootstrap method to evaluate image noise for investigation of axial collimation in hybrid PET

被引:2
|
作者
Groiselle, CJ [1 ]
Glick, SJ [1 ]
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, Div Nucl Med, Worcester, MA 01655 USA
关键词
axial collimation; bootstrap; noise; PET; 3D OSEM list-mode iterative reconstruction;
D O I
10.1109/TNS.2005.843625
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The purpose of this paper was to investigate, the use of the bootstrap method to evaluate noise in three-dimensional (3-D) ordered-subsets expectation-maximization list-mode iterative reconstructions from data simulated on a hybrid positron emission tomography (PET) system. In addition, image noise from reconstructions acquired with various levels of axial collimation was investigated. A warm cylinder (20-cm diameter and 70-cm long) was simulated using the GEANT 3.21 Monte Carlo simulation code for different collimator designs: open-frame (OPEN), parallel (PAR) axial, and hybrid parallel fan-beam (HPF) axial collimators. Twenty noisy sets of list-mode data were simulated for each collimator. In addition, events from the first noisy list-mode data set of each category (OPEN, PAR axial, and HPF axial collimators) were chosen at random with replacement to produce twenty new sets of the same size. List-mode data were reconstructed using a 3-D ordered-subsets expectation-maximization (OSEM) list-mode iterative reconstruction algorithm using two subsets and up to 10 iterations. The standard deviations within volumes of interest (VOIs) were computed, and the mean value of this estimate over noise realizations was evaluated. The results indicate that there is no statistical significant difference in the standard deviation of VOI estimates from noisy realizations and bootstrap samples when using the OPEN, the PAR axial, and the HPF axial collimators. The results showed that the precision of VOI estimates varies with the axial spatial location within the object and the axial collimator. In addition, noise variation within list-mode reconstructed images appears to be related to the 3-D sensitivity map.
引用
收藏
页码:95 / 101
页数:7
相关论文
共 50 条
  • [1] Using the bootstrap method to evaluate image noise for investigation of axial collimation in hybrid PET
    Groiselle, CJ
    Glick, SJ
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 782 - 785
  • [2] Estimation of image noise in PET using the bootstrap method
    Dahlbom, M
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2075 - 2079
  • [3] Estimation of image noise in PET using the bootstrap method
    Dahlbom, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2062 - 2066
  • [4] Impact of axial collimation on Hybrid PET image quality
    Groiselle, CJ
    Glick, SJ
    [J]. 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 549 - 552
  • [5] Determination of image noise in PET using the bootstrap method.
    Dahlbom, M
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 11P - 11P
  • [6] A new method to evaluate the PET image quality based on the image noise and reproducibility of recovery coefficients
    Akamatsu, Go
    Taniguchi, Takafumi
    Kidera, Daisuke
    Kihara, Ken
    Mikasa, Shohei
    Komiya, Isao
    Sasaki, Masayuki
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [7] THE EFFECTS OF COLLIMATION ON PET IMAGE NOISE DUE TO SCATTER, RANDOM COUNTS, AND DEADTIME
    THOMPSON, CJ
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1991, 11 (02): : A31 - A37
  • [8] Using the ACR PET Phantom to Evaluate Interscan Noise in PET
    Carroll, J.
    Turkington, T.
    Davis, R.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3127 - 3127
  • [9] Quantitative evaluation of PET image using event information bootstrap
    Song, Hankyoel
    Kwak, Shin Hye
    Kim, Kyeong Min
    Kang, Joo Hyun
    Chung, Yong Hyun
    Woo, Sang-Keun
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [10] Bootstrap methods for estimating PET image noise: experimental validation and an application to evaluation of image reconstruction algorithms
    Masanobu Ibaraki
    Keisuke Matsubara
    Kazuhiro Nakamura
    Hiroshi Yamaguchi
    Toshibumi Kinoshita
    [J]. Annals of Nuclear Medicine, 2014, 28 : 172 - 182