A Three-Layered Osteochondral Plug: Structural, Mechanical, and in vitro Biocompatibility Analysis

被引:20
|
作者
Aydin, Halil Murat [1 ]
机构
[1] Hacettepe Univ, Inst Sci, Bioengn Div, TR-06800 Ankara, Turkey
关键词
ARTICULAR-CARTILAGE REPAIR; CANCELLOUS BONE; DEFECTS; SCAFFOLDS; CHONDROCYTES; COLLAGEN; MATRIX; HYDROXYAPATITE; REGENERATION; COMPOSITES;
D O I
10.1002/adem.201180005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study aims to produce an osteochondral plug with three distinct layers resembling the naturally occurring cartilage, tidemark, and subchondral zones, for the regeneration of defects of articular cartilage. The bone layer is constructed from a PLLA/PCL polymeric blend using a dual-porogen approach. The pore surfaces are coated with type-I collagen and hydroxyapatite. The upper layer, made of PGA nonwoven felt, is combined with the lower using a polymeric blend with a pigment for better visualization during implantation. Vertical channels are formed from the bottom layer to the upper border of the tidemark to facilitate the delivery of stem cells and blood from the bone marrow when implanted. The Young's modulus of the osteochondral plugs is 94.5 +/- 9.42 kPa. Cell-culture studies confirm the biocompatibility.
引用
收藏
页码:B511 / B517
页数:7
相关论文
共 50 条
  • [1] Theory analysis of pressure distribution in the three-layered reservoir
    Li, S.C.
    Huang, B.G.
    Wang, N.T.
    Zhang, P.Z.
    Xinan Shiyou Xueyuan Xuebao/Journal of Southwestern Petroleum Institute, 2001, 23 (05):
  • [2] The Construction of Three-Layered Biomimetic Arterial Graft Balances Biomechanics and Biocompatibility for Dynamic Biological Reconstruction
    Bao, Han
    Zhang, Yanyuan
    Xin, He
    Gao, Ye
    Hou, Yan
    Yue, Guichu
    Wang, Nu''
    Wang, Yaqiong
    Li, Chun
    Liu, Fuwei
    Zhao, Yong
    Kong, Liang
    ACS OMEGA, 2024, 9 (07): : 7609 - 7620
  • [3] BUCKLING ANALYSIS OF THREE-LAYERED RECTANGULAR PLATE WITH PIEZOELECTRIC LAYERS
    Yaghoobi, Hessameddin
    Rajabi, Iraj
    JOURNAL OF THEORETICAL AND APPLIED MECHANICS, 2013, 51 (04) : 813 - 826
  • [4] Stability analysis of three-layered film journal bearing with slip
    Rao, T. V. V. L. N.
    Rani, A. M. A.
    Awang, M.
    Hashim, F. M.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON ADVANCED PROCESSES AND SYSTEMS IN MANUFACTURING (APSIM 2016), 2016, : 99 - 100
  • [5] A Three-Layered Approach to Radiation Therapy Software Recall Analysis
    Pishko, G.
    Oliveri, C. M.
    Zhang, J.
    Bhullar, A. S.
    Ohara, M. D.
    Dill, D. B.
    Jung, W. C.
    Miller, D. L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E498 - E499
  • [6] A Three-layered Contrasting Analysis of the Theme in Once more to the lake
    杨晶
    海外英语, 2017, (13) : 163 - 165
  • [7] Improvement of a Three-Layered in vitro Skin Model for Topical Application of Irritating Substances
    Schmidt, Freia F.
    Nowakowski, Sophia
    Kluger, Petra J.
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2020, 8
  • [8] MICROSTRUCTURAL ANALYSIS AND MECHANICAL PROPERTIES OF THREE-LAYERED STACK OF FSAM AA7075-CU ALLOYS
    Nallusamy, M.
    Suriyaprakash, M.
    Kiran, K.
    Jayachitra, M.
    SURFACE REVIEW AND LETTERS, 2024, 31 (01)
  • [9] Vibration analysis of geometrically imperfect three-layered sheardeformable microbeams
    Ghayesh, Mergen H.
    Farokhi, Hamed
    Gholipour, Alireza
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2017, 122 : 370 - 383
  • [10] Buckling analysis of three-layered rectangular plate with piezoelectric layers
    1600, Polish Society of Theoretical and Allied Mechanics (51):