Femoral Revision in Hip Resurfacing Compared With Large-Bearing Metal-on-Metal Hip Arthroplasty

被引:4
|
作者
Garrett, Simon J. W. [1 ]
Bolland, Ben J. R. F. [1 ,2 ]
Yates, Piers J. [1 ,3 ,4 ]
Gardner, Edward M. H. [1 ]
Latham, Jeremy M. [1 ]
机构
[1] Southampton Gen Hosp, Dept Trauma & Orthopaed, Southampton SO9 4XY, Hants, England
[2] Southampton Gen Hosp, Southampton SO9 4XY, Hants, England
[3] Univ Western Australia, Nedlands, WA 6009, Australia
[4] Fremantle Hosp, Dept Orthopaed & Trauma, Fremantle, WA, Australia
来源
JOURNAL OF ARTHROPLASTY | 2011年 / 26卷 / 08期
关键词
failed hip resurfacing; metal-on-metal bearing; revision surgery; hip arthroplasty; NONOPERATIVE MANAGEMENT; FOLLOW-UP; BIRMINGHAM; REPLACEMENT; FRACTURES; OSTEOARTHRITIS; DISLOCATION; COMPONENT;
D O I
10.1016/j.arth.2010.10.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
It has been suggested that revision of the femoral component of hip resurfacing after femoral failure would be straightforward and have an outcome comparable to primary total hip arthroplasty (THA). We have compared the outcome of femoral side only revision resurfacings to the results of primary modular large-bearing metal-on-metal THA. Fourteen consecutive patients underwent revision surgery of the failed femoral component, to a cemented tapered stem (CPT, Zimmer, Warsaw, Indiana) with a large modular metal head (Smith and Nephew Orthopaedics Ltd, Memphis, Tennessee, or Adept, Finsbury Orthopaedics, Surrey, England). The acetabular component was found to be well fixed, well orientated, and was left in situ. The 14 matched patients in the primary THA group received the same components. At a mean follow-up of 49 months (range, 30-60 months), clinical outcome measured using the Oxford and Harris Hip Scores showed no significant difference (P = .11, P = .45, respectively). Operative time and blood loss were comparable for both groups. We conclude that revision of the failed femoral resurfacing component gives excellent results.
引用
收藏
页码:1214 / 1218
页数:5
相关论文
共 50 条
  • [1] Revision Total Hip Arthroplasty for Aseptically Failed Metal-On-Metal Hip Resurfacing Arthroplasty
    Salmons, Harold I.
    Fruth, Kristin M.
    Lewallen, David G.
    Trousdale, Robert T.
    Berry, Daniel J.
    Abdel, Matthew P.
    [J]. JOURNAL OF ARTHROPLASTY, 2022, 37 (12): : 2399 - 2405
  • [2] Revision rates for metal-on-metal hip resurfacing and metal-on-metal total hip arthroplasty - a systematic review
    Sorensen, Sofie-Amalie L. Ras
    Jorgensen, Henrik L.
    Sporing, Sune L.
    Lauritzen, Jes B.
    [J]. HIP INTERNATIONAL, 2016, 26 (06) : 515 - 521
  • [3] Outcomes After Revision of Metal-on-Metal Hip Resurfacing Arthroplasty
    Gross, Thomas P.
    Liu, Fei
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (09): : 219 - 223
  • [4] Hip resurfacing and metal-on-metal total hip arthroplasty
    Beverland, David E.
    Spencer, Robert F.
    [J]. HIP INTERNATIONAL, 2011, 21 (03) : 277 - 278
  • [5] Metal-on-metal hip resurfacing arthroplasty
    Shimmin, Andrew
    Beaule, Paul E.
    Campbell, Pat
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (03): : 637 - 654
  • [6] Revision of metal-on-metal resurfacing arthroplasty of the hip - The influence of malpositioning of the components
    De Haan, R.
    Campbell, P. A.
    Su, E. P.
    De Smet, K. A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (09): : 1158 - 1163
  • [7] Gait analysis of patients with metal-on-metal resurfacing hip arthroplasty compared with big-femoral-head total hip arthroplasty
    Chen, Yun-Su
    Zhao, Song
    Cao, Le
    Zhang, Xian-Long
    [J]. SAUDI MEDICAL JOURNAL, 2011, 32 (04) : 394 - 399
  • [8] Revision of Failed Hip Resurfacing and Large Metal-on-Metal Total Hip Arthroplasty Using Dual-Mobility Components
    Snir, Nimrod
    Park, Brian K.
    Garofolo, Garret
    Marwin, Scott E.
    [J]. ORTHOPEDICS, 2015, 38 (06) : 369 - 374
  • [9] Is a cementless fixation of the femoral component suitable for metal-on-metal hip resurfacing arthroplasty?
    Amstutz, Harlan C.
    Le Duff, Michel J.
    [J]. HIP INTERNATIONAL, 2019, 29 (06) : 624 - 629
  • [10] Dislocation of large-diameter head metal-on-metal total hip arthroplasty and hip resurfacing arthroplasty
    Miettinen, Simo S. A.
    Makinen, Tatu J.
    Laaksonen, Inari
    Makela, Keijo
    Huhtala, Heini
    Kettunen, Jukka S.
    Remes, Ville
    [J]. HIP INTERNATIONAL, 2019, 29 (03) : 253 - 261