Correlation between Voltage Endurance and Dielectric Loss Tangent/Partial Discharge for Stator Coils of HV Motors

被引:0
|
作者
Ren, Haiyang [1 ]
Jiang, Songlin [1 ,2 ]
Yu, Qinxue [1 ]
He, Jiaxi [1 ,3 ]
Zhong, Lisheng [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
[2] Elect Power Supply Co, State Grid Tianfu New Area, Chengdu 610041, Peoples R China
[3] State Grid Changzhou Power Supply Co, Changzhou 213000, Peoples R China
关键词
HV motors; stator coils; voltage endurance; tan delta; partial discharge; correlation;
D O I
10.1109/CEIDP49254.2020.9437526
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Vacuum pressure impregnation (VPI) technique is now widely used in the insulation systems of high voltage (HV) motors and generators due to good electrical, mechanical and thermal performances. The voltage endurance, dielectric loss tangent and partial discharge are the most common and effective means to assess the electrical properties of full-size stator coils. In this paper, the relationship between voltage endurance and tan delta as well as the partial discharge is investigated for stator coils with the rated voltage (U-n) of 10kV. The voltage endurance test is carried out at 311. 50Hz. The tano measurement is performed over the voltage range of 0.2 U.1.2 U. with intervals of 0.2U(n). Partial discharge is measured to obtain the inception voltage, extinction voltage and Q(ICE) values in the operating voltage (Un/root 3) and the rated voltage (U.). It has been found that the coil group with longer voltage endurance tends to show lower tan delta and tip-up, higher inception and extinction voltages and smaller apparent partial charges. It manifests that the destructive voltage endurance test and non-destructive diagnostic measurements of tan delta and partial discharge have good consistency in assessing the insulation properties for HV coils. Moreover, calculations of correlation coefficients between voltage endurance and tan delta or partial discharge parameters show that the tan delta and partial discharge magnitude at the operating voltage can be more effective for evaluating the quality and estimating the lifetime of insulation system for HV coils, compared with such parameters measured at the rated voltage.
引用
收藏
页码:535 / 538
页数:4
相关论文
共 10 条
  • [1] RELATIONSHIP BETWEEN PARTIAL DISCHARGE PULSE-HEIGHT ANALYSIS AND SUBSEQUENT VOLTAGE ENDURANCE OF STATOR BARS AND COILS
    MCDERMID, W
    BROMLEY, JC
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 1992, 7 (04) : 721 - 731
  • [2] Correlation between Dielectric Loss and Partial Discharge of Oil-Pressboard Insulation
    Li, Yan
    Li, Min
    Xie, Jun
    [J]. SYMMETRY-BASEL, 2021, 13 (05):
  • [3] A high voltage cables terminator for partial discharge and dielectric loss measurement
    Boonseng, C
    Apiratikul, P
    Nakaviwat, K
    [J]. CONFERENCE RECORD OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2002, : 62 - 65
  • [4] Partial discharge location by cross-talk phenomena between three phase stator coils of generators
    Cheng, YC
    Li, CR
    Wang, W
    Liu, D
    [J]. Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 506 - 509
  • [5] Surge Test-Based Identification of Stator Insulation Component With Partial Discharge Activity for Low Voltage AC Motors
    Lee, Sang Bin
    Naeini, Alireza
    Jayaram, Shesha
    Stone, Greg C.
    Sasic, Mladen
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (03) : 2541 - 2549
  • [6] Modeling of the Partial Discharge Process Between the Winding and the Stator of Low Voltage Machines for Traction Applications
    Pauli, Florian
    Kilper, Moritz
    Driendl, Niklas
    Hameyer, Kay
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2021, 36 (03) : 2310 - 2318
  • [7] A NEW TECHNIQUE FOR THE REMOTE PARTIAL DISCHARGE MONITORING OF THE STATOR INSULATION OF HIGH-VOLTAGE MOTORS LOCATED IN "Ex" (HAZARDOUS) LOCATIONS
    Renforth, Lee
    Armstrong, Russell
    Clark, David
    Goodfellow, Steven
    Hamer, Paul. S.
    [J]. 2012 RECORD OF CONFERENCE PAPERS INDUSTRY APPLICATIONS SOCIETY 59TH ANNUAL IEEE PETROLEUM AND CHEMICAL INDUSTRY TECHNICAL CONFERENCE (PCIC), 2012,
  • [8] The correlation between partial discharge characteristics and space charge accumulation under AC voltage
    Jeon, SI
    Nam, SH
    Shin, DS
    Park, IH
    Han, MK
    [J]. 2000 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS. I & II, 2000, : 653 - 656
  • [9] Correlation between Partial Discharge Inception Voltage and Breakdown Voltage Characteristics of Butt-gap in HVDC Mass Impregnated PPLP Cable
    Oh, Dong-Hun
    Lee, Ho-Young
    Kim, Sun-Jin
    Lee, Bang-Wook
    [J]. 2018 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2018, : 518 - 521
  • [10] Investigation on the Frequency Dependence of the Correlation Between Discharge Current and Gap Voltage in Helium Dielectric Barrier Discharges at Atmospheric Pressure
    Li, Xiaotong
    Tan, Zhenyu
    Wang, Xiaolong
    Liu, Yadi
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2020, 48 (06) : 2060 - 2074