Hybrid wind-diesel powered system DC link stability analysis taking into account load disturbances

被引:0
|
作者
Tankari, A. M. [1 ]
Dakyo, B. [1 ]
Nichita, C. [1 ]
机构
[1] GREAH Univ Le Havre, Le Havre, France
关键词
renewable energy systems; hybrid power integration; alternative energy; dispersed storage and generation;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
We have showed that frequency bands of interaction as well as dynamics of energy flow to the point of common coupling (PCC) lead to hybrid system design keys [9]. In case of a given system it is obvious that PCC will be influenced by the disturbances from the load. This can affect the stability for the worst. Related to each power source and the load behaviour, storage devices and control strategy must lead to a good stability of the total system. This paper deals with how to take in to account the segmentation of frequency domain to achieve stability by efficient design of storage and control principle.
引用
下载
收藏
页码:2789 / 2794
页数:6
相关论文
共 50 条
  • [1] Improved sizing method of storage units for hybrid wind-diesel powered system
    Tankari, A. M.
    Dakyo, B.
    Nichita, C.
    2008 13TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-5, 2008, : 1911 - 1917
  • [2] A new method to define power and energy share in a DC link hybrid wind-diesel powered system by means of storage and dual time-frequency
    Dakyo, B.
    El Mokadem, M.
    Nichita, C.
    Koczara, W.
    2007 EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-10, 2007, : 4745 - +
  • [3] Load Frequency Control for Wind-Diesel Hybrid Systems
    Tan Wen
    Zhang Jifen
    2011 30TH CHINESE CONTROL CONFERENCE (CCC), 2011, : 5126 - 5131
  • [4] Optimized Hybrid Wind-Diesel Energy System with Feasibility Analysis
    Arefin S.S.
    Das N.
    Technology and Economics of Smart Grids and Sustainable Energy, 2 (1):
  • [5] Wind-Diesel Hybrid System with Flexible DC-Bus Voltage Level
    Belsky, Aleksey A.
    Dobush, Vasily S.
    Ivanchenko, Daniil I.
    2015 INTERNATIONAL SIBERIAN CONFERENCE ON CONTROL AND COMMUNICATIONS (SIBCON), 2015,
  • [6] Time scale stability analysis of a Hopf bifurcation in a wind-diesel hybrid microgrid
    Choque Pillco, Edwin
    Costa Alberto, Luis Fernando
    de Oliveira, Ricardo Vasques
    IET RENEWABLE POWER GENERATION, 2020, 14 (09) : 1491 - 1501
  • [7] Ecological Analysis of a Wind-Diesel Hybrid Power System in the South Algeria
    Allali, Khaireddine
    Azzag, El Bahi
    EXERGY FOR A BETTER ENVIRONMENT AND IMPROVED SUSTAINABILITY 2: APPLICATIONS, 2018, : 925 - 934
  • [8] Effect of load management and optimal sizing on the economics of a wind-diesel hybrid power system
    Panickar, P.S.
    Islam, S.M.
    Pryor, T.L.
    2000, Institution of Engineers (Australia) (20):
  • [9] On Determining the Optimal Composition of Wind-Diesel Power Complexes Taking into Account Local Conditions
    Nikolaev V.V.
    Nikolaev V.G.
    Kharchenko V.V.
    Russian Electrical Engineering, 2018, 89 (3) : 186 - 192
  • [10] Adjustable speed hybrid wind-diesel generation system
    Iwanski, Grzegorz
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2011, 30 (01) : 186 - 200