Experimental Evaluation and Modeling of Corroded Reinforced Concrete Columns

被引:30
|
作者
Yalciner, Hakan [1 ,2 ]
Kumbasaroglu, Atila [1 ,3 ]
机构
[1] Erzincan Binali Yildirim Univ, Dept Civil Engn, Erzincan, Turkey
[2] Struct Res Ctr, Dept Civil Engn, Erzincan, Turkey
[3] Erzincan Binali Yildirim Univ, Res Corros Studies, Erzincan, Turkey
关键词
assessment; column; corrosion; reinforcement bar; seismic; SEISMIC PERFORMANCE; CORROSION INFLUENCE; CYCLIC BEHAVIOR; BRIDGE PIERS; BARS;
D O I
10.14359/51721372
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A total of 30 full-scale reinforced concrete (RC) columns were tested to develop models for the prediction of the structural behavior of corroded RC columns. Of these, 25 RC columns were tested under cyclic loading for two different applied axial load ratios-namely, 0.20 and 0.40-at three concrete strength levels-namely, 9, 27, and 37 MPa (1305, 3915, and 5365 psi)-and at four corrosion levels. Five RC columns were loaded monotonically with an axial load ratio of 0.20 at four corrosion levels to calculate the damage index. The actual corrosion levels were obtained by breaking the concrete and extracting all the reinforcing bars. The test results demonstrated that the ductility ratios of the corroded RC columns, which were not determined in accordance with energy-based or bilateral failure criteria, could be misleading. The determined energy dissipation capacity and damage index of the columns further revealed the corrosion effects.
引用
收藏
页码:61 / 76
页数:16
相关论文
共 50 条
  • [1] Structural modeling of corroded reinforced concrete bridge columns
    Rao, A. S.
    Lepech, M. D.
    Kiremidjian, A. S.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, RESILIENCE AND SUSTAINABILITY, 2012, : 1008 - 1014
  • [2] Numerical Modeling of Uniaxial Corroded Reinforced Concrete Columns Exposed to Fire
    Ba, Guangzhong
    Wu, Weijian
    Dai, Hongchao
    Jiao, Yu
    Zhang, Jie
    BUILDINGS, 2024, 14 (09)
  • [3] Experimental study on reinforced concrete corroded columns under loading condition
    Rani, M. Usha
    Subramanian, K.
    BULLETIN OF ELECTROCHEMISTRY, 2006, 22 (06): : 263 - 268
  • [4] Seismic evaluation of corroded reinforced concrete columns based on Pushover analysis
    Cheng, Ling
    Gong, Jin-Xin
    Li, Ying
    Zhendong yu Chongji/Journal of Vibration and Shock, 2012, 31 (10): : 19 - 23
  • [5] Seismic Modelling of Corroded Reinforced Concrete Columns
    El-Joukhadar, Nicolas
    Dameh, Farah
    Pantazopoulou, Stavroula
    ENGINEERING STRUCTURES, 2023, 275
  • [6] Fire Performance of Corroded Reinforced Concrete Columns
    Chandra, Shashank
    Sharma, Umesh Kumar
    Green, Mark
    Gales, John
    Bhargava, Pradeep
    FIRE TECHNOLOGY, 2024, 60 (04) : 2265 - 2295
  • [7] Deformation limits of corroded reinforced concrete columns
    Liu, Xiaojuan
    Zhong, Tao
    Jiang, Huanjun
    Liu, Yang
    Zixiong, Guo
    STRUCTURES, 2023, 49 : 903 - 917
  • [8] Fragility functions for corroded reinforced concrete columns
    Dai, Kuang-Yu
    Yu, Xiao-Hui
    Qian, Kai
    JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [9] Modeling of corroded FRP-Wrapped reinforced concrete columns in axial compressionMod
    Debaiky, Ahmed S.
    Green, Mark F.
    Hope, Brian B.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2007, 11 (06) : 556 - 564
  • [10] An experimental study on seismic performance levels of highly corroded reinforced concrete columns
    Celik, Alper
    Yalciner, Hakan
    Kumbasaroglu, Atila
    Turan, Ahmet Ihsan
    STRUCTURAL CONCRETE, 2022, 23 (01) : 32 - 50