Flow-based fluorimetric determination of furosemide in pharmaceutical formulations and biological samples:: Use of micelar media to improve sensitivity

被引:15
|
作者
Semaan, Felipe Silva [1 ]
Nogueira, Paulo Alberto [1 ]
Gomes Cavalheiro, Eder Tadeu [1 ]
机构
[1] USP, Inst Quim Sao Carlos, Dept Quim & Fis Mol, BR-13560970 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
furosemide determination; antihypertensive drug analysis; flow injection fluorimetry; micelar media;
D O I
10.1080/00032710701746782
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two fast flow injection procedures with fluorimetric detection based on the furosemide emission are presented. The first configuration used a phosphate buffer solution pH 3.00, 0.2 ionic strength (mu) solution flowing at 3.0mlmin-1 as carrier, a 80cm sample loop (400 mu l total sample injection), and a 40cm long reactor coil, which was kept at room temperature; the second has a unique difference: the introduction of a new channel of surfactant solution with reduction of flow rate. The excitation and emission were carried out at 270 and 410nm, respectively; both systems presented linear dynamic range from 1.0 x 10(-7) to 1.0 x 10(-5) mol 1(-1). The limit of detection (3 sigma/slope) was 3.0 x 10(-8) mol 1(-1), to the first system, and 10(-8) mol 1(-1) for the second one. Both proposed methods were applied to three commercial samples from different suppliers, as tablets and ampoules, and a synthetic urine sample spiked with the analyte. They presented an analytical frequency of 90 and 60 measurements per hour, respectively to phosphate and micelar media. The results agreed with those from the label and determined by a UV-Vis spectrophotometric comparative procedure. Recoveries around 101% were found in the commercial formulations and synthetic urine matrixes.
引用
收藏
页码:66 / 79
页数:14
相关论文
共 8 条
  • [1] Use of green fluorescent nano-sensors for the determination of furosemide in biological samples and pharmaceutical preparations
    Mona H. Abo Zaid
    Nahed El-Enany
    Aziza E. Mostafa
    Ghada M. Hadad
    Fathalla Belal
    BMC Chemistry, 17
  • [2] Use of green fluorescent nano-sensors for the determination of furosemide in biological samples and pharmaceutical preparations
    Zaid, Mona Abo H.
    El-Enany, Nahed
    Mostafa, Aziza E.
    Hadad, Ghada M.
    Belal, Fathalla
    BMC CHEMISTRY, 2023, 17 (01)
  • [3] Miniaturized ionophore-based potentiometric sensors for the flow-injection determination of metformin in pharmaceutical formulations and biological fluids
    Khaled, Elmorsy
    Kamel, Manal S.
    Hassan, Hassan N.
    Abd El-Alim, Sameh H.
    Aboul-Enein, Hassan Y.
    ANALYST, 2012, 137 (23) : 5680 - 5687
  • [4] Flow-based determination of methionine in pharmaceutical formulations exploiting TGA-capped CdTe quantum dots for enhancing the luminol-KIO4 chemiluminescence
    Zhou, Min
    Wang, Ailian
    Li, Cong
    Luo, Xiaowei
    Ma, Yongjun
    JOURNAL OF LUMINESCENCE, 2017, 183 : 206 - 211
  • [5] Stopped-flow kinetic method for the fluorimetric determination of DNA traces in biological samples based on the interaction long-wavelength fluorophor, surfactant and nucleic acid
    Manzano-Ayala, H. R.
    Romero, J. M. Fernandez
    Gomez-Hens, A.
    ANALYTICA CHIMICA ACTA, 2009, 632 (01) : 109 - 114
  • [6] Selective and sensitive electroanalytical biosensor based on Poly([Cu (H2O)2P2]I2)/GCE for the determination of esomeprazole in pharmaceutical formulations and biological fluid samples
    Metto, Melaku
    Tesfaye, Alemu
    Atlabachew, Minaleshewa
    Abebe, Atakilt
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2024, 19 (11):
  • [7] THE USE OF A MONOLITHIC COLUMN TO IMPROVE THE SIMULTANEOUS DETERMINATION OF CAFFEINE, PARACETAMOL, PSEUDOEPHEDRINE, ASPIRIN, DEXTROMETHORPHAN, CHLORPHENIRAMINE IN PHARMACEUTICAL FORMULATIONS BY HPLC-A COMPARISON WITH A CONVENTIONAL REVERSED-PHASE SILICA-BASED COLUMN
    Hadad, Ghada M.
    Mahmoud, Waleed M. M.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (20) : 2516 - 2532
  • [8] Coupling on-line preconcentration by ion-exchange with ETAAS. A novel flow injection approach based on the use of a renewable microcolumn as demonstrated for the determination of nickel in environmental and biological samples
    Wang, JH
    Hansen, EH
    ANALYTICA CHIMICA ACTA, 2000, 424 (02) : 223 - 232