Ozonation of Municipal Secondary Effluent; Removal of Hazardous Micropollutants and Related Changes of Organic Matter Composition

被引:0
|
作者
Domenjoud, Bruno [1 ]
Cortes-Francisco, Nuria [2 ]
Guastalli, Andrea R. [3 ]
Caixach, Josep [2 ]
Esplugas, Santiago [1 ]
Baig, Sylvie [3 ]
机构
[1] Univ Barcelona, Dept Chem Engn, E-08028 Barcelona, Spain
[2] CSIC, IDAEA, Mass Spectrometry Lab, ES-08034 Barcelona, Spain
[3] Degremont SA, F-92508 Rueil Malmaison, France
关键词
Advanced oxidation processes; Dissolved organic matter; Fractionation; Micropollutant; Municipal effluent; Ozone; WASTE-WATER TREATMENT; ACTIVATED CARBON; TREATMENT PLANTS; PHARMACEUTICALS; ENVIRONMENT; OXIDATION; FRAGRANCES; SUBSTANCES; RIVERS;
D O I
暂无
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The major part of the regulated priority substances and family of compounds defined in the European Water Framework Directive and some other organic micropollutants were tracked in a municipal biotreated secondary effluent. Micropollutants detected in the effluent were subjected to different ozone doses related to different oxidation extents. Ozone confirmed its efficiency in terms of micropollutant reduction when applied to a municipal biotreated effluent. Accordingly, it achieved reductions exceeding 70% for 91% of the pollutants detected at high ozone dose. Organic matter transformation was also investigated by both controlling evolution of surrogates including chemical oxygen demand, dissolved organic carbon, UV254 absorbance, etc. - and the fate dissolved organic fractions by means of size exclusion chromatography followed by organic carbon detection. At ozone dose lower than the initial ozone demand of the effluent, ozone first attacked the hydrophobic aromatic compounds. At ozone dose higher than 50 mg/L, ozone probably solubilized suspended particles and principally oxidized high molecular weight molecules (> 1,000 Da) to convert them into more hydrophilic compounds. Therefore, most reactions of ozone with the micropollutants take place in competition with fast reactions of ozone with the hydrophobic fraction of the dissolved organic matter.
引用
收藏
页码:138 / 146
页数:9
相关论文
共 50 条
  • [1] Removal of Organic Micropollutants from a Municipal Wastewater Secondary Effluent by UVA-LED Photocatalytic Ozonation
    Chavez, Ana M.
    Ribeiro, Ana R.
    Moreira, Nuno F. E.
    Silva, Adrian M. T.
    Rey, Ana
    Alvarez, Pedro M.
    Beltran, Fernando J.
    [J]. CATALYSTS, 2019, 9 (05):
  • [2] Ozonation in advanced treatment of secondary municipal wastewater effluents for the removal of micropollutants
    Dogruel, Serdar
    Atesci, Zuhal Cetinkaya
    Aydin, Egemen
    Pehlivanoglu-Mantas, Elif
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2020, 27 (36) : 45460 - 45475
  • [3] Ozonation in advanced treatment of secondary municipal wastewater effluents for the removal of micropollutants
    Serdar Dogruel
    Zuhal Cetinkaya Atesci
    Egemen Aydin
    Elif Pehlivanoglu-Mantas
    [J]. Environmental Science and Pollution Research, 2020, 27 : 45460 - 45475
  • [4] Reactivity of dissolved effluent organic matter (EfOM) with hydroxyl radical as a function of its isolated fractions during ozonation of municipal secondary effluent
    Zhang, Yunhui
    Wang, Yun
    Li, Yong
    Xu, Zuxin
    Li, Huaizheng
    Jin, Wei
    [J]. WATER RESEARCH, 2023, 242
  • [5] Innovative combination of Fe2+-BAF and ozonation for enhancing phosphorus and organic micropollutants removal treating petrochemical secondary effluent
    Wu, Changyong
    Zhou, Yuexi
    Wang, Yi
    Guo, Mingkun
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2017, 323 : 654 - 662
  • [6] Optimizing Micropollutant Removal by Ozonation; Interference of Effluent Organic Matter Fractions
    van Gijn, K.
    Sohier, J.
    Maasdam, R.
    de Wilt, H. A.
    Rijnaarts, H. H. M.
    Langenhoff, A. A. M.
    [J]. OZONE-SCIENCE & ENGINEERING, 2021, 43 (06) : 579 - 591
  • [7] Effects of effluent organic matter (EfOM) on the removal of emerging contaminants by ozonation
    Cai, Ming-Jhih
    Lin, Yi-Pin
    [J]. CHEMOSPHERE, 2016, 151 : 332 - 338
  • [8] Application of CFD modelling at a full-scale ozonation plant for the removal of micropollutants from secondary effluent
    Launer, M.
    Lyko, S.
    Fahlenkamp, H.
    Jagemann, P.
    Ehrhard, P.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2013, 68 (06) : 1336 - 1344
  • [9] 'Green' coagulant application with activated carbon: dosing sequence and removal of selected micropollutants and effluent organic matter from municipal wastewater
    Ivancev-Tumbas, Ivana
    Bogunovic, Minja
    Vasic, Vesna
    Sciban, Marina
    Tubic, Aleksandra
    Macerak, Anita Leovac
    Prodanovic, Jelena
    [J]. ENVIRONMENTAL TECHNOLOGY, 2022, 43 (08) : 1163 - 1169
  • [10] Influence of effluent particles and particle-bound micropollutants on the removal of micropollutants and UVA254 in wastewater effluent ozonation
    Qian, Jueying
    Al-asad, Hana Atallah
    Parniske, Janna
    Brandl, Andrea
    Degenhardt, Monika
    Morck, Tobias
    [J]. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2024, 270