Automatic projection image registration for nanoscale X-ray tomographic reconstruction

被引:25
|
作者
Yu, Haiyan [1 ,2 ]
Xia, Sihao [2 ,3 ]
Wei, Chenxi [2 ]
Mao, Yuwei [4 ]
Larsson, Daniel [2 ]
Xiao, Xianghui [5 ]
Pianetta, Piero [2 ]
Yu, Young-Sang [6 ]
Liu, Yijin [2 ]
机构
[1] Donghua Univ, Coll Mech Engn, Shanghai 201620, Peoples R China
[2] SLAC Natl Accelerator Lab, Stanford Synchrotron Radiat Lightsource, Menlo Pk, CA 94025 USA
[3] Nanjing Univ Sci & Technol, Sch Elect & Opt Engn, Nanjing 210094, Jiangsu, Peoples R China
[4] Nanjing Univ Aeronaut & Astronaut, Sch Comp Sci & Technol, Nanjing 211100, Jiangsu, Peoples R China
[5] Argonne Natl Lab, Adv Photon Source, 9700 South Cass Ave, Lemont, IL 60439 USA
[6] Lawrence Berkeley Natl Lab, Adv Light Source, Berkeley, CA 94720 USA
关键词
transmission X-ray microscopy; nanoscale tomography; image registration; tomographic reconstruction; ROTATION AXIS; RESOLUTION; MICROSCOPY;
D O I
10.1107/S1600577518013929
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Novel developments in X-ray sources, optics and detectors have significantly advanced the capability of X-ray microscopy at the nanoscale. Depending on the imaging modality and the photon energy, state-of-the-art X-ray microscopes are routinely operated at a spatial resolution of tens of nanometres for hard X-rays or approximate to 10nm for soft X-rays. The improvement in spatial resolution, however, has led to challenges in the tomographic reconstruction due to the fact that the imperfections of the mechanical system become clearly detectable in the projection images. Without proper registration of the projection images, a severe point spread function will be introduced into the tomographic reconstructions, causing the reduction of the three-dimensional (3D) spatial resolution as well as the enhancement of image artifacts. Here the development of a method that iteratively performs registration of the experimentally measured projection images to those that are numerically calculated by reprojecting the 3D matrix in the corresponding viewing angles is shown. Multiple algorithms are implemented to conduct the registration, which corrects the translational and/or the rotational errors. A sequence that offers a superior performance is presented and discussed. Going beyond the visual assessment of the reconstruction results, the morphological quantification of a battery electrode particle that has gone through substantial cycling is investigated. The results show that the presented method has led to a better quality tomographic reconstruction, which, subsequently, promotes the fidelity in the quantification of the sample morphology.
引用
收藏
页码:1819 / 1826
页数:8
相关论文
共 50 条
  • [1] Projection registration of X-ray image and CT image
    Zhang, Hui
    Luo, Limin
    Shu, Huazhong
    Li, Songyi
    Haigron, Pascal
    [J]. Journal of Southeast University (English Edition), 2003, 19 (01) : 26 - 30
  • [2] X-ray fluorescence tomographic system design and image reconstruction
    Cong, Wenxiang
    Shen, Haiou
    Cao, Guohua
    Liu, Hong
    Wang, Ge
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (01) : 1 - 8
  • [3] Tomographic image reconstruction using X-ray phase information
    Momose, A
    Takeda, T
    Itai, Y
    Hirano, K
    [J]. PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 674 - 684
  • [4] Edge detection from X-ray tomographic data for geometric image registration
    Lajili, Mohamed
    Rjaibi, Badreddine
    Auroux, Didier
    Moakher, Maher
    [J]. MATHEMATICAL METHODS IN THE APPLIED SCIENCES, 2023, 46 (06) : 6324 - 6358
  • [5] COMPUTER ALGORITHM FOR TOMOGRAPHIC IMAGE RECONSTRUCTION WITH X-RAY TRANSMISSION SCANS
    CHO, ZH
    AHN, IS
    [J]. COMPUTERS AND BIOMEDICAL RESEARCH, 1975, 8 (01): : 8 - 25
  • [6] Image quality optimization for automatic warping registration in x-ray DSA
    Talukdar, AS
    Wilson, DL
    [J]. PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 549 - 552
  • [7] Automatic focus algorithms for TDI X-Ray image reconstruction
    Doerr, J.
    Rosenbaum, M.
    Sauer-Greff, W.
    Urbansky, R.
    [J]. ADVANCES IN RADIO SCIENCE, 2012, 10 : 145 - 151
  • [8] X-ray tomographic reconstruction of macromolecular samples
    Brockhauser, Sandor
    Di Michiel, Marco
    McGeehan, John E.
    McCarthy, Andrew A.
    Ravelli, Raimond B. G.
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2008, 41 : 1057 - 1066
  • [9] Tomographic image via background subtraction using an x-ray projection image and a priori computed tomography
    Zhang, Jin
    Yi, Byongyong
    Lasio, Giovanni
    Suntharalingam, Mohan
    Yu, Cedric
    [J]. MEDICAL PHYSICS, 2009, 36 (10) : 4433 - 4439
  • [10] Fast X-ray/CT image registration based on perspective projection triangular features
    Sun, Yuanxi
    Zhang, Huiqin
    Chen, Xiaohong
    Huang, Shandeng
    Bai, Long
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2024, 112