An automatic ambulatory device for detection of AASM defined arousals from sleep: the WP100

被引:71
|
作者
Pillar, G
Bar, A
Betito, M
Schnall, RP
Dvir, I
Sheffy, J
Lavie, P
机构
[1] Technion Israel Inst Technol, Bruce Rappaport Fac Med, Sleep Lab, Haifa, Israel
[2] Itamar Med Ltd, Caesarea, Israel
关键词
sleep; autonomic nervous system; arousals; peripheral arterial tone; ambulatory monitoring; sympathetic activation;
D O I
10.1016/S1389-9457(02)00254-X
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives and background: Arousals from sleep are associated with increased sympathetic activation and therefore with peripheral vasoconstriction. Sleep fragmentation in the form of multiple arousals is associated with daytime somnolence and cognitive impairment; however, manual scoring of arousal is time consuming and problematic due to relatively high inter-scorer variability. We have recently shown that automated analysis of in-lab recorded peripheral arterial tone (PAT) signal and the pulse rate derived from it can accurately assess arousals from sleep as defined by the American Academy of Sleep Medicine (AASM). In the current study we sought to extend these findings to the Watch_PAT100 (WP100), an ambulatory device measuring PAT, oximetry and actigraphy. Methods: Sixty-eight subjects (61 patients referred to the sleep lab with suspected obstructive sleep apnea and seven healthy volunteers, mean age 46.3 +/- 14.2 years) underwent a whole night polysomnography (PSG) with simultaneous recording of PAT signal by the ambulatory WP100 device. The PSG recordings were blindly manually analyzed for arousals based on AASM criteria, while PAT was scored automatically based on the algorithm developed previously. Results: There was a significant correlation between AASM arousals derived from the PSG and PAT autonomic arousals derived from the WP100 (R = 0.87, P < 0.001), with a good agreement across a wide range of values. The sensitivity and specificity of PAT in detecting patients with at least 20 arousals per hour of sleep were 0.80 and 0.79, respectively, with a receiver operating characteristic curve having an area under the curve of 0.87. Conclusions: We conclude that automatic analysis of peripheral arterial tonometry signal derived from the ambulatory device Watch_PAT100 can accurately identify arousals from sleep in a simple and time saving fashion. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:207 / 212
页数:6
相关论文
共 50 条
  • [1] An automatic ambulatory device for detection of ASDA defined arousals from sleep: The WP100
    Pillar, G
    Betito, M
    Bar, A
    Sheffy, J
    Lavie, P
    [J]. SLEEP, 2002, 25 : A37 - A37
  • [2] A method for the automatic detection of arousals during sleep
    De Carli, F
    Nobili, L
    Gelcich, T
    Ferrillo, T
    [J]. SLEEP, 1999, 22 (05) : 561 - 572
  • [3] THE ESCHERICHIA-COLI WP2/WP100 REC ASSAY FOR DETECTION OF POTENTIAL CHEMICAL CARCINOGENS
    MAMBER, SW
    BRYSON, V
    KATZ, SE
    [J]. MUTATION RESEARCH, 1983, 119 (02): : 135 - 144
  • [4] Quantitative sleep EEG synchronization analysis for automatic arousals detection
    Erdamar, Aykut
    Aksahin, Mehmet Feyzi
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 59
  • [5] Automatic detection of cortical arousals in sleep and their contribution to daytime sleepiness
    Brink-Kjaer, Andreas
    Olesen, Alexander Neergaard
    Peppard, Paul E.
    Stone, Katie L.
    Jennum, Poul
    Mignot, Emmanuel
    Sorensen, Helge B. D.
    [J]. CLINICAL NEUROPHYSIOLOGY, 2020, 131 (06) : 1187 - 1203
  • [6] Sensitivity and specificity of visual and automatic detection of cortical arousals in sleep
    Gruber, G.
    Anderer, P.
    Parapatics, S.
    Moreau, A.
    Woertz, M.
    Danker-Hopfe, H.
    Zeitlhofer, J.
    Dorffner, G.
    [J]. JOURNAL OF SLEEP RESEARCH, 2008, 17 : 235 - 236
  • [7] Automatic Detection of Arousals During Sleep Using Multiple Physiological Signals
    Parvaneh, Saman
    Rubin, Jonathan
    Samadani, Ali
    Katuwal, Gajendra
    [J]. 2018 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2018, 45
  • [8] Automatic artifacts and arousals detection in whole-night sleep EEG recordings
    't Wallant, Dorothee Coppieters
    Muto, Vincenzo
    Gaggioni, Giulia
    Jaspar, Mathieu
    Chellappa, Sarah L.
    Meyer, Christelle
    Vandewalle, Gilles
    Maquet, Pierre
    Phillips, Christophe
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2016, 258 : 124 - 133
  • [9] Nocturnal partial seizures and arousals/awakenings from sleep: An ambulatory EEG study
    Manni, R
    Galimberti, CA
    Sartori, I
    Politini, L
    Murelli, R
    Tartara, A
    [J]. FUNCTIONAL NEUROLOGY, 1997, 12 (3-4) : 107 - 111
  • [10] Automatic, electrocardiographic-based detection of autonomic arousals and their association with cortical arousals, leg movements, and respiratory events in sleep
    Olsen, Mads
    Schneider, Logan Douglas
    Cheung, Joseph
    Peppard, Paul E.
    Jennum, Poul J.
    Mignot, Emmanuel
    Sorensen, Helge Bjarup Dissing
    [J]. SLEEP, 2018, 41 (03)