Reconstruction of Mandibular Defects Using a Custom-Made Titanium Tray in Combination With Autologous Cancellous Bone

被引:10
|
作者
Zhou, Libin [1 ]
Zhao, Jinlong [1 ]
Shang, Hongtao [1 ]
Liu, Wei [1 ]
Feng, Zhihong [2 ]
Liu, Guicai [3 ]
Wang, Jing [4 ]
Liu, Yanpu [5 ]
机构
[1] Fourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Mfg Syst Engn, Dept Prosthodont, Xian, Shaanxi, Peoples R China
[3] Xi An Jiao Tong Univ, State Key Lab Mfg Syst Engn, Dept Oral & Maxillofacial Surg, Xian, Shaanxi, Peoples R China
[4] Fourth Mil Med Univ, Xijing Hosp, Dept Nucl Med, Xian 710032, Shaanxi, Peoples R China
[5] Fourth Mil Med Univ, Xijing Hosp, Dept Oral & Maxillofacial Surg, Xian 710032, Shaanxi, Peoples R China
关键词
D O I
10.1016/j.joms.2010.06.185
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To esthetically and functionally restore a 40-mm canine mandibular discontinuity defect using a custom-made titanium bone-grafting tray packed with autologous iliac bone. Materials and Methods: Individualized titanium bone-grafting trays were made using a reverse engineering, computer-aided design, and rapid prototyping technique. A 40-mm discontinuity defect in the right mandibular body was created in 10 hybrid dogs. The defect was restored immediately using the tray that was densely packed with autologous cancellous iliac particles and covered with trimmed iliac chips. Sequential radionuclide bone imaging was performed postoperatively at 2, 4, 8, 12, and 24 weeks. The ratio of activity between the grafted mandible and the contralateral native mandible on each transaxial slice was calculated. The mean activity ratio was analyzed at each time point to evaluate the bone metabolism and reconstitution of the grafts. The subjects were sacrificed at 4, 12, and 24 weeks after grafting. The specimens were evaluated by postmortem gross dissection, biomechanical testing, 3-dimensional microcomputed tomographic scanning, and histologic examination. Results: All the subjects tolerated the grafting operation well. Over an observation period of 24 weeks, tray extrusion occurred in 3 of the 10 subjects. Bony continuities were reconstructed in 9 of the 10 subjects. Radionuclide bone imaging revealed that the tracer uptake increased in the grafted mandible, and the radionuclide ratio between the graft and the native mandible decreased with time. Gross evaluation, microcomputed tomographic examination, biomechanical testing, and histologic examination demonstrated corticalization of the grafts. Conclusions: The use of a customized technique using reverse engineering, computer-aided design, and rapid prototyping tray containing autologous cancellous bone is a potentially powerful grafting technique for the reconstruction of mandibular discontinuity defects. (C) 2011 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 69:1508-1518, 2011
引用
收藏
页码:1508 / 1518
页数:11
相关论文
共 50 条
  • [1] Custom-made titanium mandibular reconstruction tray
    Samman, N
    Luk, WK
    Chow, TW
    Cheung, LK
    Tideman, H
    Clark, RKF
    [J]. AUSTRALIAN DENTAL JOURNAL, 1999, 44 (03) : 195 - 199
  • [2] Mandibular reconstruction using custom-made titanium mesh tray and particulate cancellous bone and marrow harvested from bilateral posterior ilia
    Yamada, Hiroyuki
    Nakaoka, Kazutoshi
    Horiuchi, Toshikatsu
    Kumagai, Kenichi
    Ikawa, Tomoko
    Shigeta, Yuko
    Imamura, Eisaku
    Iino, Mitsuyoshi
    Ogawa, Takumi
    Hamada, Yoshiki
    [J]. JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2014, 48 (03) : 183 - 190
  • [3] Clinical Usefulness of Mandibular Reconstruction Using Custom-Made Titanium Mesh Tray and Autogenous Particulate Cancellous Bone and Marrow Harvested From Tibia and/or Ilia
    Yamada, Hiroyuki
    Nakaoka, Kazutoshi
    Sonoyama, Tomoo
    Kumagai, Kenichi
    Ikawa, Tomoko
    Shigeta, Yuko
    Harada, Naohiko
    Kawamura, Noboru
    Ogawa, Takumi
    Hamada, Yoshiki
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (03) : 586 - 592
  • [4] Custom-Made Titanium Mesh Tray for Mandibular Reconstruction Using an Electron Beam Melting System
    Hoshi, Isao
    Kawai, Tadashi
    Kurosu, Shingo
    Minamino, Tadaharu
    Onodera, Kei
    Miyamoto, Ikuya
    Yamada, Hiroyuki
    [J]. MATERIALS, 2021, 14 (21)
  • [5] Reconstruction of complex mandibular defects using integrated dental custom-made titanium implants
    Rachmiel, A.
    Shilo, D.
    Blanc, O.
    Emodi, O.
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2017, 55 (04): : 425 - 427
  • [6] DACRON MESH TRAY AND CANCELLOUS BONE IN RECONSTRUCTION OF MANDIBULAR DEFECTS
    ALBERT, TW
    SMITH, JD
    EVERTS, EC
    COOK, TA
    [J]. ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1986, 112 (01) : 53 - 59
  • [7] Reconstruction of the alveolar cleft using a custom-made titanium mesh tray and particulate cancellous bone and marrow in an elderly patient with cleft lip and palate: A case report
    Kajita, Tomonari
    Nogami, Shinnosuke
    Matsui, Keiko
    Kataoka, Yoshihiro
    Kurobane, Tsuyoshi
    Koyama, Shigeto
    Takahashi, Tetsu
    Yamauchi, Kensuke
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2023, 35 (05) : 428 - 432
  • [8] Outcomes of mandibular reconstruction using three-dimensional custom-made porous titanium prostheses
    Haroun, Fabienne
    Benmoussa, Nadia
    Bidault, Francois
    Lassau, Nathalie
    Moya-Plana, Antoine
    Leymarie, Nicolas
    Honart, Jean-Francois
    Kolb, Frederic
    Qassemyar, Quentin
    Gorphe, Philippe
    [J]. JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2023, 124 (01)
  • [9] Custom-made cast titanium implants produced with CAD/CAM for the reconstruction of cranium defects
    Heissler, E
    Fischer, FS
    Bolouri, S
    Lehmann, T
    Mathar, W
    Gebhardt, A
    Lanksch, W
    Bier, J
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1998, 27 (05) : 334 - 338
  • [10] Mandibular Reconstruction With Fibula Bone Graft Followed by Particulate Cancellous Bone and Marrow Graft With Titanium Mesh Tray
    Ozaki, Hisashi
    Sakurai, Hiromasa
    Yusa, Kazuyuki
    Kitabatake, Kenichirou
    Kobayashi, Takehito
    Iino, Mitsuyoshi
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (04) : 381 - 384