Impact of stereotactic large-core needle biopsy on diagnosis and surgical treatment of nonpalpable breast cancer

被引:41
|
作者
Verkooijen, HM
Rinkes, IHMB
Peeters, PHM
Landheer, MLEA
van Es, NJ
Mali, WPTM
Klinkenbijl, JHG
van Vroonhoven, TJMV
机构
[1] Univ Med Ctr Utrecht, Dept Surg, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Julius Ctr Patient Oriented Res, Utrecht, Netherlands
[3] Rijnstate Hosp Arnhem, Dept Surg, Arnhem, Netherlands
[4] Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
来源
EUROPEAN JOURNAL OF SURGICAL ONCOLOGY | 2001年 / 27卷 / 03期
关键词
large-core needle biopsy; nonpalpable breast cancer;
D O I
10.1053/ejso.2000.1102
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Stereotactic large-core needle biopsy is increasingly replacing needle-localized breast biopsy for the diagnosis of nonpalpable breast disease. In this prospective study, the impact of the introduction of this technique on diagnosis and surgical treatment of nonpalpable breast cancer was assessed in two hospitals in The Netherlands. Patients and methods: A total of 84 patients with nonpalpable breast cancer, diagnosed by means of stereotactic large-core needle biopsy (needle biopsy group) were compared with 80 patients diagnosed with nonpalpable breast cancer before the introduction of large-core needle biopsy. These patients were diagnosed by means of needle-localized open breast biopsy (control group). Clinical outcome measures evaluated included: duration of diagnostic and therapeutic intervals and number of surgical procedures required for complete surgical treatment. Subgroup analysis was performed for the category of microcalcifications without tissue distortion. Results: For the needle biopsy group, the median interval between initial referral to the surgeon and the availability of histological diagnosis was 9 days and the interval between initial referral and complete surgical treatment was 31 days, These intervals were significantly longer for the control group (19 days and 44 days respectively); 75% of patients in the needle biopsy group were treated in a single step surgical procedure compared to 16% of the patients in the control group (67 vs 25% respectively for the subgroup). The mean number of surgical procedures required to complete surgical treatment was 1.31 for needle biopsy group vs 1.91 for the open biopsy group (1.46 vs 1.84 for the subgroup). Conclusion: Introduction of stereotactic large-core needle biopsy leads to a reduction of the time to diagnosis and the time to complete surgical treatment of nonpalpable breast cancer. It also reduces the number of surgical procedures required for complete surgical treatment of nonpalpable breast cancer. The benefits of large-core needle biopsy may also be anticipated for patients with microcalcifications without tissue distortion. (C) 2001 Harcourt Publishers Ltd.
引用
收藏
页码:244 / 249
页数:6
相关论文
共 50 条
  • [1] Large-core needle biopsy of nonpalpable breast cancers - The impact on subsequent surgical excisions
    Smith, DN
    Christian, R
    Meyer, JE
    [J]. ARCHIVES OF SURGERY, 1997, 132 (03) : 256 - 259
  • [2] Large-core needle biopsy of nonpalpable breast lesions
    Meyer, JE
    Smith, DN
    Lester, SC
    Kaelin, C
    DiPiro, PJ
    Denison, CM
    Christian, RL
    Harvey, SC
    Selland, DLG
    Durfee, SM
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 281 (17): : 1638 - 1641
  • [4] Benefits of diagnosing nonpalpable breast cancer with stereotactic large-core needle biopsy: Lower costs and fewer operations
    Jackman, RJ
    Marzoni, FA
    Finkelstein, SI
    Shepard, MJ
    [J]. RADIOLOGY, 1996, 201 : 993 - 993
  • [5] Large-core needle biopsy for diagnosis and treatment of breast lesions
    Smyczek-Gargya B.
    Krainick U.
    Müller-Schimpfle M.
    Mielke G.
    Mayer R.
    Siegmann K.
    Mehnert F.
    Vogel U.
    Ruck P.
    Wallwiener D.
    Fersis N.
    [J]. Archives of Gynecology and Obstetrics, 2002, 266 (4) : 198 - 200
  • [6] The impact of stereotactic large-core needle biopsy in the treatment of patients with nonpalpable breast lesions: a study of diagnostic accuracy in 510 consecutive cases
    F. J. Andreu
    M. Sentís
    E. Castañer
    X. Gallardo
    I. Jurado
    M. Jesùs Díaz-Ruíz
    I. Méndez
    M. Rey
    R. Florensa
    [J]. European Radiology, 1998, 8 : 1468 - 1474
  • [7] The impact of stereotactic large-core needle biopsy in the treatment of patients with nonpalpable breast lesions: a study of diagnostic accuracy in 510 consecutive cases
    Andreu, FJ
    Sentis, M
    Castanier, E
    Gallardo, X
    Jurado, I
    Diaz-Ruiz, MJ
    Mendez, I
    Rey, M
    Florensa, R
    [J]. EUROPEAN RADIOLOGY, 1998, 8 (08) : 1468 - 1474
  • [8] A comparative study on the accuracy of histopathologic diagnosis of nonpalpable breast lesions based on large-core needle biopsy and open surgical biopsy
    Verkooijen, HM
    Peterse, JL
    Schipper, MEI
    Buskens, E
    Hendriks, J
    Pijnappel, RM
    Holland, R
    [J]. JOURNAL OF PATHOLOGY, 2001, 193 : 27A - 27A
  • [9] Cost-effectiveness of stereotactic large-core needle biopsy for nonpalpable breast lesions compared to open-breast biopsy
    Groenewoud, JH
    Pijnappel, RM
    van den Akker-van Marle, ME
    Birnie, E
    Buijs-van der Woude, T
    Mali, WTPM
    de Koning, HJ
    Buskens, E
    [J]. BRITISH JOURNAL OF CANCER, 2004, 90 (02) : 383 - 392
  • [10] Cost-effectiveness of stereotactic large-core needle biopsy for nonpalpable breast lesions compared to open-breast biopsy
    J H Groenewoud
    R M Pijnappel
    M E van den Akker-van Marle
    E Birnie
    T Buijs-van der Woude
    W P Th M Mali
    H J de Koning
    E Buskens
    [J]. British Journal of Cancer, 2004, 90 : 383 - 392