Pressure drop of wet gas flow with ultra-low liquid loading through DP meters

被引:7
|
作者
Zheng, Xuebo [1 ]
He, Denghui [1 ,2 ]
Bai, Bofeng [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Shaanxi, Peoples R China
[2] Xian Univ Technol, State Key Lab Ecohydraul Northwest Arid Reg, Xian 710048, Shaanxi, Peoples R China
关键词
Wet gas; Pressure drop; DP meter; Non-monotonicity; Low liquid loading; DIFFERENTIAL PRESSURE; 2-PHASE; COEFFICIENT; FRACTION; RATES;
D O I
10.1016/j.flowmeasinst.2019.101664
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The most common method to predict the gas and liquid flow rates in a wet gas flow simultaneously is to use dual pressure drops (dual-DPs) from two or even one single DP meter. In this paper, the metering mechanism of applying dual-DPs were overviewed. To fully understand the response of DP meters to wet gas flows, the pressure drops of wet gas flow with ultra-low liquid loading through three typical DP meters were experimentally investigated, including an orifice plate meter, a cone meter and a Venturi meter. The equivalent diameter ratio is 0.45. The experimental fluids are air and tap water. The pressure is in the range of 0.1-0.3 MPa and the Lockhart-Martinelli parameter (X-LM) is less than approximately 0.02. The results show that the upstream-throat pressure drop, the downstream-throat pressure drop and the permanent pressure loss of individual DP meters have unique response to liquid loading. The upstream-throat pressure drop of the orifice plate meter decreases at first and then increases as the liquid loading increases, while that of the cone meter and the Venturi meter increase monotonically. The non-monotonicity of the pressure drop for the orifice plate meter can be attributed to the flow modulation of trace liquid. The downstream-throat pressure drops of all the three test sections decrease at first and then increase. The reason is that the liquid presence in a gas flow increases the downstream friction and vortex dissipation. The permanent pressure loss of the orifice plate meter also shows non-monotonicity. To avoid non-monotonicity, the pressure loss ratio is introduced, which is defined as the ratio of the permanent pressure loss to the upstream-throat pressure drop. Results show that the pressure loss ratio of the Venturi meter has the highest sensitivity to the liquid loading.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Holdup and pressure drop in liquid-loading gas-liquid flow
    Liu, Lei
    Zhou, Fangde
    Wang, Yueshe
    [J]. Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2002, 36 (05): : 469 - 472
  • [2] Experimental research on pressure drop of wet gas flow in Venturi
    Yuan, Chao
    Xu, Ying
    Zhang, Tao
    Wei, Jing
    Wang, Huaxiang
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2016, 75 : 183 - 188
  • [3] A comprehensive comparison of the performance of several popular models to predict pressure drop in stratified gas-liquid flow with low liquid loading
    Banafi, A.
    Talaei, M. R.
    Ghafoori, Mj.
    [J]. JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2014, 21 : 433 - 441
  • [4] Low liquid loading gas/liquid pipe flow
    Zhang, Hong-Quan
    Sarica, Cem
    [J]. JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2011, 3 (02) : 413 - 422
  • [5] PRESSURE-DROP FOR GAS-LIQUID FLOW
    BALASUBRAMANIAN, GR
    KOGANTI, SB
    NATARAJAN, R
    [J]. CHEMICAL ENGINEERING, 1980, 87 (11) : 101 - 102
  • [6] GAS FLOW AND PRESSURE DROP THROUGH MOVING BEDS
    HAPPEL, J
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1971, 10 (03): : 421 - &
  • [7] GAS FLOW AND PRESSURE DROP THROUGH MOVING BEDS
    YOON, SM
    KUNII, D
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1970, 9 (04): : 559 - &
  • [8] CFD study of the transient wet gas flow behavior through orifice plate flow meters
    Weise, Josiane
    Balino, Jorge L.
    Paladino, Emilio E.
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 82
  • [9] Foam flow in vertical gas wells under liquid loading: Critical velocity and pressure drop prediction
    Ajani, Abdulkamil
    Kelkar, Mohan
    Sarica, Cem
    Pereyra, Eduardo
    [J]. INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2016, 87 : 124 - 135
  • [10] Low Pressure Gas Percolation Characteristic in Ultra-low Permeability Porous Media
    Yue Xiang'an
    Wei Haoguang
    Zhang Lijuan
    Zhao Renbao
    Zhao Yongpan
    [J]. TRANSPORT IN POROUS MEDIA, 2010, 85 (01) : 333 - 345