Analysis of Cascade Vapour Refrigeration System with Various Refrigerants

被引:21
|
作者
Logesh, K. [1 ]
Baskar, S. [2 ]
Azeemudeen, Md M. [1 ]
Reddy, B. Praveen [1 ]
Jayanth, Gajavalli Venkata Subba Sai [1 ]
机构
[1] Vel Tech Rangarajan Dr Sagunthala R&D Inst Sci &, Dept Mech Engn, Chennai 600062, Tamil Nadu, India
[2] VISTAS, Dept Automobile Engn, Chennai, Tamil Nadu, India
关键词
Coefficient of performance; Evaporator; Condenser; Heat Exchanger; Cascade Refrigeration system; CONICAL STRIP INSERTS; HEAT-TRANSFER; PERFORMANCE; TUBE; EXCHANGER; BIODIESEL; EMISSION;
D O I
10.1016/j.matpr.2019.07.450
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper report the performance analysis of different refrigerants couples in cascade refrigeration system. Refrigerants such as R134a/R23, R410A/R23 and R404A/R170 have been successfully analyzed in the superheating and sub cooling range of 10 degrees C and 5 degrees C respectively. The variation in condenser temperature was from 30 to 50 degrees C in high temperature circuit while evaporator temperature in low temperature circuit varied in the range of -70 degrees C to -50 degrees C. The compressor efficiency was assumed to be 0.7 throughout the experiment. It has been revealed that there is enhancement in coefficient of performance and flow rate with rise in compressor work and evaporator temperature. From the present study we conclude that the refrigerant pair R134a/R170 was found to have greater coefficient of performance and lower mass flow rate and the pair R404A/R508B was found to have smaller coefficient of performance and greater mass flow rate. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4659 / 4664
页数:6
相关论文
共 50 条
  • [1] Analysis of a vapour ejector refrigeration system with environment friendly refrigerants
    Selvaraju, A
    Mani, A
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2004, 43 (09) : 915 - 921
  • [2] Calculation and analysis for an ejector refrigeration system with various refrigerants
    Wang, Fei
    Shen, Shengqiang
    [J]. Huagong Xuebao/CIESC Journal, 2010, 61 (02): : 275 - 280
  • [3] Performance analysis of refrigerants with various expansion valves in vapour compression refrigeration and air-conditioning system
    Sivaraman, N.
    Vaidyanathan, R. Muthu
    Patel, Mahaboob
    Markos, Mebratu
    [J]. MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 2465 - 2469
  • [4] COMPARISON OF VARIOUS ALTERNATIVE REFRIGERANTS FOR VAPOUR COMPRESSION REFRIGERATION SYSTEMS
    Dalkilic, Ahmet Sellm
    Wongwises, Somchai
    [J]. PROCEEDINGS OF THE ASME/JSME 8TH THERMAL ENGINEERING JOINT CONFERENCE 2011, VOL 1 PTS A AND B, 2011, : 1425 - +
  • [5] Entropy generation and exergy destruction analyses for vapour compression refrigeration system with various refrigerants
    Ankur Geete
    Mamta Sharma
    Pranjal Shrimali
    [J]. SN Applied Sciences, 2019, 1
  • [6] Entropy generation and exergy destruction analyses for vapour compression refrigeration system with various refrigerants
    Geete, Ankur
    Sharma, Mamta
    Shrimali, Pranjal
    [J]. SN APPLIED SCIENCES, 2019, 1 (07)
  • [7] A performance comparison of vapour-compression refrigeration system using various alternative refrigerants
    Dalkilic, A. S.
    Wongwises, S.
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (09) : 1340 - 1349
  • [8] A finite time analysis of a cascade refrigeration system using alternative refrigerants
    Agnew, B
    Ameli, SM
    [J]. APPLIED THERMAL ENGINEERING, 2004, 24 (17-18) : 2557 - 2565
  • [9] Energy and exergy analysis of low GWP refrigerants in cascade refrigeration system
    Sun, Zhili
    Wang, Qifan
    Xie, Zhiyuan
    Liu, Shengchun
    Su, Dandan
    Cui, Qi
    [J]. ENERGY, 2019, 170 : 1170 - 1180
  • [10] Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants
    Thangavel, P.
    Somasundaram, P.
    [J]. JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2013, 72 (07): : 454 - 460