A Case Study of Mutual Impedance Effect in Parallel Transmission Lines Under Maintenance Condition

被引:0
|
作者
Mangunkusumo, Kevin Gausultan Hadith [1 ]
Kusuma, Aristo Adi [1 ]
Munir, Buyung Sofiarto [1 ]
机构
[1] PLN Res Inst, Transmiss & Distribut Dept, Jakarta, Indonesia
来源
PROCEEDINGS OF 2018 THE 10TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND ELECTRICAL ENGINEERING (ICITEE) | 2018年
关键词
Parallel lines; mutual impedance; double circuit; transmission;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Parallel lines are utilized to enhance the reliability and security of energy. Mutual impedance arises when transmission lines are parallel lines on a common right way. In this study, a system model to observed mutual impedance effect between parallel disrupted lines and under maintenance line are explained. The system model is validated using actual recorded fault current waveform. The simulation result shows that when disconnector of the under maintenance line open and grounded on both side, the line mutual current will be high. On the other hand, when disconnector open and gorunded only on one side, the line mutual current will be low but the voltage will be high.
引用
收藏
页码:192 / 195
页数:4
相关论文
共 50 条
  • [1] MUTUAL IMPEDANCE OF TRANSMISSION-LINES WITH EARTH RETURN
    AMETANI, A
    SCHINZINGER, R
    IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1980, 127 (05) : 326 - 328
  • [2] Accurate Fault Location Modeling for Parallel Transmission Lines Considering Mutual Effect
    Ziedan, Hamdy A.
    Rezk, Hegazy
    Al-Dhaifallah, Mujahed
    CMC-COMPUTERS MATERIALS & CONTINUA, 2021, 67 (01): : 491 - 518
  • [3] A new study in maintenance for transmission lines
    Department of Electric Engineering, Shanghai Jiaotong University, Shanghai 200240, China
    WSEAS Trans. Circuits Syst., 2008, 5 (392-401):
  • [4] CALCULATION OF CHARACTERISTIC IMPEDANCE WITH EDGE CONDITION IN MICROSTRIP TRANSMISSION LINES.
    Hu, Richard H.
    Smith, Charles E.
    1600, IEEE (73 CHO725-2 REG III)197, New York
  • [5] Design High Directivity Parallel-Coupled Lines with Step Impedance Transmission Lines
    Phromloungsri, Ravee
    Kumpang, Saney
    Chongcheawchamnan, Mitchai
    APMC: 2008 ASIA PACIFIC MICROWAVE CONFERENCE (APMC 2008), VOLS 1-5, 2008, : 1324 - +
  • [6] Appropriate selection of shunt compensation reactor in parallel transmission lines: A case study
    Samimi, Mohammad Hamed
    Ahmadi-Joneidi, Iman
    Majzoobi, Alireza
    Golshannavaz, Sajjad
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 96 : 163 - 173
  • [7] A modified mutual impedance based backup protection for series-compensated transmission lines
    Anand, Shubham
    Kalita, Kaustav
    Parida, S. K.
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 224
  • [8] Design High-Directivity Parallel-Coupled Lines with Step-Impedance Transmission Lines
    Kumpang, S.
    Phromloungsri, R.
    Chongcheawchamnan, M.
    2007 ASIA PACIFIC MICROWAVE CONFERENCE, VOLS 1-5, 2007, : 1867 - 1870
  • [9] Study on condition-based maintenance effect under uncertain health evaluation
    Yang, Shu-Ming
    Qiu, Jing
    Liu, Guan-Jun
    Xu, Yu-Guo
    Wang, Chao
    Binggong Xuebao/Acta Armamentarii, 2012, 33 (02): : 252 - 256
  • [10] Fault current calculations as influenced by mutual effect between parallel lines
    El-Tamaly, H. H.
    Ziedan, H. A.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2007, 35 (09) : 1007 - 1025