Pollution by petroleum products is a source of volatile organic compounds in soil Therefore, laboratory column venting experiments were completed in order to investigate the removal of a pure compound (toluene) and a mixture of two (toluene and n-heptane) and five (toluene, n-heptane, ethylbenzene, m-xylene and p-xylene) compounds The choice of the compounds, as well as their proportion in the mixture, was made on the basis of the real fuel composition The objective of this study is a comparison between the experimental volatile organic compounds removal results and the computational fluid dynamics (CFDs) analysis The proposed model for the contaminants transport describes the removal of organic compounds from soil, the contaminants being distributed among four phases vapor, nonaqueous liquid phase, aqueous and "solid", the local phase's equilibrium and the ideal behavior of all four phases was found to be accurate enough to describe the interphase mass transfer The process developed in the lab consists of a heater/boiler that pumps and circulates hot oil through a pipeline that is enclosed in a larger-diameter pipe This extraction pipe is vertically installed within the contaminated soil up to a certain depth and is welded at the bottom and capped at the top The number of heat source pipes and extraction wells depends on the type of soil, the type of pollutants, and the moisture content of the soil and the size of the area to be cleaned The heat source heats the soil, which is transported in the interior part of the soil by means of conduction and convection This heating of the soil results in vaporization of the gases, which are then driven out of the soil by the extraction well The extraction well consists of the blower, which sucks the vaporized gases out of the system Our previous studies have removed higher boiling compounds, such as naphthalene, etc, to a non-detectable level Thus, the current technology is very promising for removing most of the chemical compounds, and can also remove these high boiling compounds from the saturated zone The reasonable agreement between the predicted and the experimental results as well as the values of the performance criteria prove that the mathematical model is suitable to describe the removal of volatile organic compound pollutants by venting in the range of experimental conditions used in the pilot plant