Life Cycle Cost Analysis of Air Conditioning Systems in a Perimeter Zone for a Variable Air Volume System in Office Buildings

被引:5
|
作者
Na, Yeon-Jeong
Nam, Eun-Ji [2 ]
Yang, In-Ho [1 ]
机构
[1] Dongguk Univ, Dept Architectural Engn, Seoul, South Korea
[2] Dongguk Univ, Grad Sch Architectural Engn, Seoul, South Korea
关键词
perimeter air conditioning; variable air volume(VAV) system; convector; fan coil unit(FCU); fan powered unit(FPU); life cycle cost(LCC); LCC analysis;
D O I
10.3130/jaabe.9.243
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, an economic analysis of systems adopted as the perimeter zone system in office buildings such as convector, fan coil unit(FCU) and fan powered unit(FPU) was performed, with the variable air volume(VAV) system applied in the interior zone. The initial cost of each alternative, such as the construction cost of the air conditioning system, was determined by planning and design, and energy cost as running cost was calculated on the basis of the energy consumption of each system using a computer simulation. Economic analysis was performed using life cycle cost(LCC), with the present value method for the air conditioning system in the perimeter zone. The results show that FPU is the most economical air conditioning system. When VAV is applied to the interior zone, LCC of the FCU is reduced by 6% and the cost of FPU is reduced 9% less than that of the convector system.
引用
收藏
页码:243 / 250
页数:8
相关论文
共 50 条
  • [1] Life-cycle cost analysis for constant-air-volume and variable-air-volume air-conditioning systems
    Aktacir, MA
    Büyükalaca, O
    Yilmaz, T
    [J]. APPLIED ENERGY, 2006, 83 (06) : 606 - 627
  • [2] Energy efficient fuzzy based combined variable refrigerant volume and variable air volume air conditioning system for buildings
    Karunakaran, R.
    Iniyan, S.
    Goic, Ranko
    [J]. APPLIED ENERGY, 2010, 87 (04) : 1158 - 1175
  • [3] Exergy analysis of variable air volume systems for an office building
    Wei, Zhentao
    Zmeureanu, Radu
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (02) : 387 - 392
  • [4] Energy efficient PCM-based variable air volume air conditioning system for modern buildings
    Parameshwaran, R.
    Harikrishnan, S.
    Kalaiselvam, S.
    [J]. ENERGY AND BUILDINGS, 2010, 42 (08) : 1353 - 1360
  • [5] COMPARISON OF LIFE CYCLE COST OF CENTRALIZED AND SPLIT AIR CONDITIONING SYSTEMS
    Hagare, Dharma
    Ho, Jason
    Saha, Swapan
    [J]. PROCEEDINGS OF INTERNATIONAL STRUCTURAL ENGINEERING AND CONSTRUCTION: INTERACTION BETWEEN THEORY AND PRACTICE IN CIVIL ENGINEERING AND CONSTRUCTION, 2016, : 621 - 626
  • [6] Global hydraulic stability analysis for dynamic regulation in multi-zone variable air volume air-conditioning system
    Zhao, Tianyi
    Li, Zhe
    Li, Xiuming
    Peng, Honglian
    [J]. Energy and Built Environment, 2024, 5 (04): : 592 - 606
  • [7] Dynamic performance of an electronic zone air temperature control loop in a typical variable-air-volume air conditioning system
    Hung, CYS
    Lam, HN
    Dunn, A
    [J]. HVAC&R RESEARCH, 1999, 5 (04): : 317 - 337
  • [8] Performance Simulation and Analysis of Occupancy-Based Control for Office Buildings with Variable-Air-Volume Systems
    Wang, Weimin
    Zhang, Jian
    Brambley, Michael R.
    Futrell, Benjamin
    [J]. ENERGIES, 2020, 13 (15)
  • [9] Measurement and simulation of indoor air quality and energy consumption in two Shanghai office buildings with variable air volume systems
    Pan, YQ
    Zhou, H
    Huang, ZH
    Zeng, Y
    Long, WD
    [J]. ENERGY AND BUILDINGS, 2003, 35 (09) : 877 - 891
  • [10] Analysis of Indoor Inhalable Particle Concentration under Variable Air Volume Air Conditioning System
    Li, Xin-long
    Huang, Yue-wu
    [J]. PROCEEDINGS OF THE 2ND 2016 INTERNATIONAL CONFERENCE ON SUSTAINABLE DEVELOPMENT (ICSD 2016), 2017, 94 : 286 - 289