Removal of ibuprofen and 4-isobutylacetophenone by non-dispersive solvent extraction using a hollow fibre membrane contactor

被引:26
|
作者
Williams, Nicia S. [1 ]
Ray, Madhumita B. [1 ]
Gomaa, Hassan G. [1 ]
机构
[1] Univ Western Ontario, Dept Chem & Biochem Engn, London, ON N6A 5B9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Ibuprofen; 4-Isobutylacetophenone; Hollow fibre membrane contactor; Mass transfer; LIQUID-LIQUID-EXTRACTION; MASS-TRANSFER; ACTIVE COMPOUNDS; AROMA COMPOUNDS; DRINKING-WATER; WASTE-WATER; SHELL-SIDE; RECOVERY; MODULES; SAMPLES;
D O I
10.1016/j.seppur.2011.11.022
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The removal of pharmaceutical pollutants such as ibuprofen (IBU) and its metabolite 4-isobutylacetophenone (4-IBAP) from water was investigated in a laboratory scale commercial hollow fibre membrane contactor by non-dispersive solvent extraction. The effects of water and solvent flow rates (92-474 ml/min) on the shell and tube side of the hollow fibre, respectively, were investigated. The hollow fibres were found to be very efficient in reducing the concentrations (10-110 mu g/ml) of the pharmaceuticals in water by approximately 90% or greater within the first couple of minutes of experiment showing extremely fast kinetics. Faster removal was obtained when the organic phase flowed at a higher rate than the aqueous feed phase. The effect of aqueous phase pH on the removal was tested in the pH range 2-10. Ibuprofen removal was greatly affected by pH with close to 100% removal occurred at pH 2, and less than 20% removal occurred at pH 10. Removal of ibuprofen metabolite (4-isobutylacetophenone) was not affected by pH, and an average removal of 96% was achieved at both basic and acidic pH. The laboratory-scale experiments were conducted in both batch and once through modes. The mass transfer coefficients were also estimated under various operating conditions. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 69
页数:9
相关论文
共 40 条
  • [1] NdFeB magnet recycling: Dysprosium recovery by non-dispersive solvent extraction employing hollow fibre membrane contactor
    Yadav, Kartikey K.
    Anitha, Mallavarapu
    Singh, D. K.
    Kain, V.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2018, 194 : 265 - 271
  • [2] Transport of uranium from nitric acid solution by non-dispersive solvent extraction using a hollow fibre contactor
    Patil, C. B.
    Mohapatra, P. K.
    Singh, R. R.
    Gurba, P. B.
    Janardan, P.
    Changrani, R. D.
    Manchanda, V. K.
    RADIOCHIMICA ACTA, 2006, 94 (6-7) : 331 - 334
  • [3] Transport of thorium from nitric acid solution by non-dispersive solvent extraction using a hollow fibre contactor
    Patil, C. B.
    Mohapatra, P. K.
    Manchanda, V. K.
    DESALINATION, 2008, 232 (1-3) : 272 - 280
  • [4] Non-dispersive solvent extraction of neodymium using a hollow fiber contactor: Mass transfer and modeling studies
    Ambare, D. N.
    Ansari, S. A.
    Anitha, M.
    Kandwal, P.
    Singh, D. K.
    Singh, H.
    Mohapatra, P. K.
    JOURNAL OF MEMBRANE SCIENCE, 2013, 446 : 106 - 112
  • [5] Non-Dispersive Solvent Extraction and Stripping of Neodymium (III) using a Hollow Fiber Contactor with TODGA as the Extractant
    Patil, C. B.
    Ansari, S. A.
    Mohapatra, P. K.
    Natarajan, V.
    Manchanda, V. K.
    SEPARATION SCIENCE AND TECHNOLOGY, 2011, 46 (05) : 765 - 773
  • [6] Non dispersive solvent extraction for removal of dissolved organic from aqueous medium using hollow fiber membrane contactor
    Singh, S. K.
    Bindu, M.
    Tripathi, S. C.
    Gandhi, P. M.
    EUROMEMBRANE CONFERENCE 2012, 2012, 44 : 1572 - 1573
  • [7] Computational modelling of non-dispersive solvent extraction of uranium in hollow fiber contactor operated in recycle mode
    Swain, Biswajit
    Sarkar, S.
    Singh, K. K.
    Pabby, Anil Kumar
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2021, 161
  • [8] Non-Dispersive Solvent Extraction of Uranium from Nitric Acid Medium by Several Amides and their Mixture with TODGA using a Hollow Fiber Contactor
    Raut, D. R.
    Mohapatra, P. K.
    SEPARATION SCIENCE AND TECHNOLOGY, 2013, 48 (16) : 2436 - 2443
  • [9] Extraction and stripping of uranium(VI) from nitric acid solution by non-dispersive extraction using a hollow fiber contactor
    Manchanda, V. K.
    Patil, C. B.
    Mohapatra, P. K.
    Gurba, P. B.
    Janardan, P.
    Changrani, R. D.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 232 : 896 - 896
  • [10] Comparative performance of non-dispersive solvent extraction using a single module and the integrated membrane process with two hollow fiber contactors
    Kumar, A
    Haddad, R
    Alguacil, FJ
    Sastre, AM
    JOURNAL OF MEMBRANE SCIENCE, 2005, 248 (1-2) : 1 - 14