Determination of atenolol by the micelle-stabilized room-temperature phosphorescence methodology
被引:5
|
作者:
Castillo, Marcela A.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Univ La Plata, Fac Ciencias Exactas, Dept Quim, Div Quim Analit, RA-1900 La Plata, ArgentinaNatl Univ La Plata, Fac Ciencias Exactas, Dept Quim, Div Quim Analit, RA-1900 La Plata, Argentina
Castillo, Marcela A.
[1
]
Gambino, Luisina Ongaro
论文数: 0引用数: 0
h-index: 0
机构:
Natl Univ La Plata, Fac Ciencias Exactas, Dept Quim, Div Quim Analit, RA-1900 La Plata, ArgentinaNatl Univ La Plata, Fac Ciencias Exactas, Dept Quim, Div Quim Analit, RA-1900 La Plata, Argentina
Gambino, Luisina Ongaro
[1
]
Polizzi, German
论文数: 0引用数: 0
h-index: 0
机构:
Natl Univ La Plata, Fac Ciencias Exactas, Dept Quim, Div Quim Analit, RA-1900 La Plata, ArgentinaNatl Univ La Plata, Fac Ciencias Exactas, Dept Quim, Div Quim Analit, RA-1900 La Plata, Argentina
Polizzi, German
[1
]
Andreetta, Hector A.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Univ La Plata, Fac Ciencias Exactas, Dept Quim, Div Quim Analit, RA-1900 La Plata, ArgentinaNatl Univ La Plata, Fac Ciencias Exactas, Dept Quim, Div Quim Analit, RA-1900 La Plata, Argentina
Andreetta, Hector A.
[1
]
Bruzzone, Liliana
论文数: 0引用数: 0
h-index: 0
机构:
Natl Univ La Plata, Fac Ciencias Exactas, Dept Quim, Div Quim Analit, RA-1900 La Plata, ArgentinaNatl Univ La Plata, Fac Ciencias Exactas, Dept Quim, Div Quim Analit, RA-1900 La Plata, Argentina
Bruzzone, Liliana
[1
]
机构:
[1] Natl Univ La Plata, Fac Ciencias Exactas, Dept Quim, Div Quim Analit, RA-1900 La Plata, Argentina
A micellar-stabilized room-temperature phosphorescence (MS-RTP) method for the determination of atenolol has been developed in micellar solutions of sodium dodecylsulphate (SDS) in the presence of thallium(I) as a heavy atom and sodium sulphite as an oxygen scavenger. The effects of thallium(I) nitrate, SDS and sodium sulphite concentrations on atenolol MS-RTP intensity were studied. Optimized conditions to obtain maximum sensitivity were 0.015 mol/L thallium(I) nitrate, 0.1 mol/L SDS and 0.0075 mol/L sodium sulphite. The maximum phosphorescence signal was completely developed in 10 min and the intensity was measured at lambda(ex) = 272 nm and lambda(em) = 412 nm. The linear range of application obtained was 2.01-16.00 mu g/mL. The detection limit estimated from the least-squares regression analysis was 0.86 mu g/mL and the relative standard deviation of 10 replicates was 1.7%. The proposed method was applied to the determination of atenolol in a pharmaceutical formulation. The quantitation was carried out by means of standard calibration, standard-additions calibration and Youden calibration. These three experiments were necessary to evaluate the presence of constant and proportional errors due to the matrix. Copyright (c) 2007 John Wiley & Sons, Ltd.