Methodological considerations in calculating heart rate variability based on wearable device heart rate samples

被引:13
|
作者
Chen, Hung-Kai [1 ]
Hu, Yu-Feng [2 ,3 ]
Lin, Shien-Fong [4 ]
机构
[1] Natl Chiao Tung Univ, Inst Elect & Comp Engn, Hsinchu, Taiwan
[2] Taipei Vet Gen Hosp, Div Cardiol, Dept Med, Taipei, Taiwan
[3] Natl Yang Ming Univ, Sch Med, Fac Med, Taipei, Taiwan
[4] Natl Chiao Tung Univ, Coll Elect & Comp Engn, Inst Biomed Engn, Hsinchu, Taiwan
关键词
Heart rate variability; Spectral analysis; Wearable device; Resampling rate; SPECTRAL-ANALYSIS; AUTONOMIC FUNCTION; MORTALITY; RISK; BEAT; HRV;
D O I
10.1016/j.compbiomed.2018.08.023
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Heart rate variability (HRV) analysis has recently been incorporated into wearable device application. The data source of HRV is the time series of heart beat intervals extracted from electrocardiogram or photoplethysmogram. These intervals are non-uniformly sampled signals and not suitable for spectral HRV analysis, which usually uses uniformly resampled heart beat intervals before calculating the spectral domain parameters. Such a practice is not applicable to heart rate data obtained from wearable devices that usually display and export the beat per minute (BPM) time series data at 1 Hz. The preferred resampling rate to calculate spectral domain parameters is 4 Hz. We compare the spectral HRV results with the 1 Hz and 4 Hz resampling rates in order to validate the use of 1 Hz resampled-RRI data to represent wearable devices BPM time series data for HRV analysis. Our results show that, using a specific combination of signal processing techniques, the lowest mean relative error in spectral domain parameters of normalized low-frequency power (LFnu), normalized high-frequency power (HFnu) and the ratio of normalized low-frequency power to normalized high-frequency power (LFnu/HFnu) between 1 Hz and 4 Hz are 3.7%, 15.3% and 16.4%, respectively. We conclude that using the heart rate data sampled at 1 Hz produces a reasonable estimation of sympathetic activity but a poor estimation of parasympathetic activity.
引用
收藏
页码:396 / 401
页数:6
相关论文
共 50 条
  • [1] An introduction to heart rate variability: methodological considerations and clinical applications
    Billman, George E.
    Huikuri, Heikki V.
    Sacha, Jerzy
    Trimmel, Karin
    [J]. FRONTIERS IN PHYSIOLOGY, 2015, 6
  • [2] Seizure detection based on heart rate variability using a wearable electrocardiography device
    Jeppesen, Jesper
    Fuglsang-Frederiksen, Anders
    Johansen, Peter
    Christensen, Jakob
    Wustenhagen, Stephan
    Tankisi, Hatice
    Qerama, Erisela
    Hess, Alexander
    Beniczky, Sandor
    [J]. EPILEPSIA, 2019, 60 (10) : 2105 - 2113
  • [3] Heart Rate Variability: A Methodological Survey
    Londhe, Aboli N.
    Atulkar, Mithilesh
    [J]. PROCEEDINGS OF THE 2019 INTERNATIONAL CONFERENCE ON INTELLIGENT SUSTAINABLE SYSTEMS (ICISS 2019), 2019, : 57 - 63
  • [4] Detection of Heart Rate Variability From a Wearable Differential ECG Device
    Slak, Jure
    Kosec, Gregor
    [J]. 2016 39TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2016, : 430 - 435
  • [5] A Design Space Exploration for Heart Rate Variability in a Wearable Smart Device
    Miranda, J. A.
    Canabal, M. F.
    Gutierrez-Martin, L.
    Lanza-Gutierrez, Jose M.
    Lopez-Ongil, C.
    [J]. 2020 XXXV CONFERENCE ON DESIGN OF CIRCUITS AND INTEGRATED SYSTEMS (DCIS), 2020,
  • [6] Wearable device assessments of antiseizure medication effects on diurnal patterns of electrodermal activity, heart rate, and heart rate variability
    Halimeh, Mustafa
    Yang, Yonghua
    Sheehan, Theodore
    Vieluf, Solveig
    Jackson, Michele
    Loddenkemper, Tobias
    Meisel, Christian
    [J]. EPILEPSY & BEHAVIOR, 2022, 129
  • [7] Sampling Rate Reduction for Wearable Heart Rate Variability Monitoring
    Nishikawa, Yuki
    Izumi, Shintaro
    Yano, Yuji
    Kawaguchi, Hiroshi
    Yoshimoto, Masahiko
    [J]. 2018 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2018,
  • [8] Accuracy of a heart rate monitor for calculating heart rate variability parameters in exercising horses
    Frippiat, Thibault
    van Beckhoven, Cees
    Moyse, Evelyne
    Art, Tatiana
    [J]. JOURNAL OF EQUINE VETERINARY SCIENCE, 2021, 104
  • [9] On the Reliability of Wearable Technology: A Tutorial on Measuring Heart Rate and Heart Rate Variability in the Wild
    Dudarev, Veronica
    Barral, Oswald
    Zhang, Chuxuan
    Davis, Guy
    Enns, James T.
    [J]. SENSORS, 2023, 23 (13)
  • [10] Heart Rate Variability and Activity Magnitude Measuring Wearable Heart Rate Sensor in Depression
    Komatsu, Yoko
    Koga, Norie
    Kimura, Hiroshi
    Shinozaki, Ryo
    Shimizu, Yusuke
    Kunugi, Hiroshi
    [J]. Transactions of Japanese Society for Medical and Biological Engineering, 2021, Annual59 (Proc): : 632 - 634