A comparative study of the corrosion of high copper dental amalgams

被引:22
|
作者
Acciari, HA [1 ]
Codaro, EN [1 ]
Guastaldi, AC [1 ]
机构
[1] UNESP, Inst Quim Araraquara, BR-14800900 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
high copper amalgam; dental materials; biomaterials; chloride corrosion; electrochemical impedance spectroscopy (EIS);
D O I
10.1016/S0167-577X(98)00038-X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Metallographic studies carried out for Tytin-Plus and Dispersalloy amalgams show a porous multiphase material, whose surface phases are: gamma-(Ag3Sn), gamma(1)-(Ag2Hg3), eta'-(Cu6Sn5) and epsilon-(Cu3Sn). Additionally, Dispersalloy is present in the Ag-Cu eutectic. The application of surface analysis by SEM reveal a heterogeneous distribution of the above mentioned phases. Microstructures consisting of colonies or clusters were not observed. The corrosion testing of these materials was done in 0.9% NaCl aerated solution at 25 degrees C using potentiodynamic polarization curves and ac impedance measurements. The corrosion process in these multiphase systems can be interpreted as the sum of more than one electrodissolution process and the posterior formation of corrosion films. On each electrode, the corrosion film is formed by different mechanisms. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:148 / 151
页数:4
相关论文
共 50 条
  • [1] Corrosion behaviour of high copper dental amalgams
    Yap, AUJ
    Ng, BL
    Blackwood, DJ
    JOURNAL OF ORAL REHABILITATION, 2004, 31 (06) : 595 - 599
  • [2] HIGH COPPER DENTAL AMALGAMS - COMPARATIVE-STUDY OF THE STRUCTURE AND THE INVITRO CORROSION-RESISTANCE
    ANGELINI, E
    ZUCCHI, F
    SURFACE TECHNOLOGY, 1985, 25 (04): : 385 - 396
  • [3] Corrosion fatigue of high-copper dental amalgams
    Mohandesi, J. Agazadeh
    Majidi, B.
    Kheradmand, A. Beygi
    CORROSION, 2007, 63 (08) : 799 - 806
  • [4] Corrosion and passivity breakdown of high copper dental amalgams
    Brett, CMA
    Aciari, HA
    Guastaldi, AC
    CORROSION AND CORROSION PROTECTION, 2001, 2001 (22): : 201 - 207
  • [5] INVIVO CORROSION DETERMINATION OF HIGH-COPPER DENTAL AMALGAMS
    GETTLEMAN, L
    COCKS, FH
    DARMIENTO, L
    LEVINE, P
    GRAHAM, JD
    JOURNAL OF DENTAL RESEARCH, 1978, 57 : 164 - 164
  • [6] CORROSION OF HIGH COPPER SILVER-TIN DENTAL AMALGAMS
    SARKAR, NK
    FUYS, RA
    STANFORD, JW
    JOURNAL OF DENTAL RESEARCH, 1978, 57 : 164 - 164
  • [7] A COMPARATIVE-STUDY OF THE ELECTROCHEMICAL CORROSION BEHAVIOR OF DENTAL AMALGAMS
    WESTERHOFF, B
    DARWISH, M
    HOLZE, R
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 1992, 22 (12) : 1142 - 1146
  • [8] CORROSION OF HIGH COPPER AMALGAMS
    OKAMOTO, A
    KOTA, K
    HOSODA, H
    JOURNAL OF DENTAL RESEARCH, 1980, 59 : 924 - 924
  • [9] STUDY OF THE CORROSION-RESISTANCE OF COPPER-RICH DENTAL AMALGAMS
    VOUGIOUKLAKIS, G
    STATHOPOULOS, A
    BATIS, G
    YFANTIS, D
    JOURNAL OF DENTAL RESEARCH, 1985, 64 (04) : 706 - 706
  • [10] COPPER CONTAINING CORROSION PRODUCTS ON COPPER RICH DENTAL AMALGAMS
    MARSHALL, SJ
    LIN, JH
    MARSHALL, GW
    JOURNAL OF DENTAL RESEARCH, 1980, 59 : 337 - 337