Dosimetric analysis of imaging changes following pulmonary stereotactic body radiation therapy

被引:3
|
作者
Prendergast, Brendan M. [1 ]
Bonner, James A. [1 ]
Popple, Richard A. [1 ]
Spencer, Sharon A. [1 ]
Fiveash, John B. [1 ]
Keene, Kimberly S. [1 ]
Cerfolio, Robert J. [2 ]
Minnich, Douglas J. [2 ]
Dobelbower, Michael C. [1 ]
机构
[1] Univ Alabama Birmingham, Dept Radiat Oncol, Birmingham, AL USA
[2] Univ Alabama Birmingham, Dept Thorac Surg, Birmingham, AL USA
关键词
pulmonary; radiosurgery; SBRT; thoracic; toxicity; CT APPEARANCE; LUNG-TUMORS; 4; FRACTIONS; PHASE-I/II; INJURY; RADIOTHERAPY; SBRT; TOXICITY; GY;
D O I
10.1111/j.1754-9485.2010.02234.x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The aim of this study was to determine whether late patterns of pulmonary fibrosis are related to specific radiation doses administered during thoracic stereotactic body radiation therapy (SBRT). Methods: The records of all patients treated with SBRT for either pulmonary metastases or inoperable primary lung tumours at the University of Alabama at Birmingham from November 2005 to July 2008 were reviewed. Patients selected for analysis had diagnostic chest computed tomography (CT) scans acquired at least 180 days after completion of therapy. CT scans acquired at follow-up were co-registered with the original treatment planning CT scans for 12 eligible patients (17 lesions), and late-occurring pulmonary imaging abnormalities (IAs) were contoured. Dosimetric parameters analysed include D-80, D-90, V-18 and V-prescription dose of the IA and V-14 and V-18 of the lung. Results: Late pulmonary IAs were identified in 11 treated areas from nine patients. Late IAs could not be identified in six treated areas from three patients secondary to emphysema, tumour progression and severe atelectasis, respectively. The mean doses to 80% (D-80) and 90% (D-90) of the IAs were 18.4 and 14.5 Gy, respectively (ranges: 5.6-27.8 and 3.3-22.4 Gy). On average, 79.4% (range: 45.6-97.5%) of the IA received at least 18 Gy, while an average of 19.3% (range: 0.2-42.2%) received the prescription dose. On average, only 4.2% (range: 1.1-7.8%) of the lungs received 18 Gy. Conclusion: Imaging abnormalities consistent with pulmonary fibrosis are common after SBRT and are well approximated by the 18 Gy isodose distribution. The clinical ramification of these findings should be evaluated in future studies.
引用
收藏
页码:90 / 96
页数:7
相关论文
共 50 条
  • [1] Pulmonary Artery Pseudoaneurysm Following Stereotactic Body Radiation Therapy
    Sabir, R.
    Umar, M.
    Khan, A.
    Gurung, P.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [2] Dosimetric Analysis of Hepatic Toxicity after Stereotactic Body Radiation Therapy
    Luo, R.
    Su, T. S.
    Liang, P.
    Cheng, T.
    Zhou, Y.
    Huang, Y.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S56 - S57
  • [3] Assessment of biological dosimetric margin for stereotactic body radiation therapy
    Kawahara, Daisuke
    Saito, Akito
    Ozawa, Shuichi
    Shiinoki, Takehiro
    Kimura, Tomoki
    Tsubouchi, Kento
    Nagata, Yasushi
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (04): : 31 - 41
  • [4] Dosimetric Impact of Liver Rotations in Stereotactic Body Radiation Therapy
    Pinnaduwage, D.
    Paulsson, A.
    Sudhyadhom, A.
    Chen, J.
    Chang, A.
    Anwar, M.
    Gottschalk, A.
    Yom, S. S.
    Descovich, M.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3303 - 3303
  • [5] Correlation of Clinical and Dosimetric Parameters With Radiographic Lung Injury Following Stereotactic Body Radiation Therapy
    Kishan, A.
    Wang, J.
    Yu, V.
    Ruan, D.
    Cao, M.
    Tenn, S.
    Low, D.
    Lee, P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S504 - S504
  • [6] Radiographic Changes in Lung of Patients Treated with Stereotactic Ablative Body Radiation Therapy and the Dosimetric Correlations
    Wang, Fen
    Park, John
    Kimler, Bruce F.
    Badkul, Rajeev
    Kumar, Parvesh
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2015, 10 (09) : S441 - S441
  • [7] Dosimetric Analysis of Kidney Toxicity After Stereotactic Body Radiation Therapy for Pancreatic Cancer
    Bhirud, A. R.
    Lin, C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S313 - S313
  • [8] Radiomic Analysis of Radiation Induced Fibrosis Following Stereotactic Body Radiation Therapy
    Escott, C.
    Madden, N. A.
    Schreibmann, E.
    Tian, S.
    Cassidy, R. J., III
    Sutter, A. I.
    Whitaker, D.
    Switchenko, J.
    Pfister, N. T.
    Xu, K. M.
    Force, S.
    Ramalingam, S.
    Curran, W. J., Jr.
    Higgins, K. A.
    Patel, P. R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E505 - E506
  • [9] Passively Scattered Proton Stereotactic Body Radiation Therapy for Spine Metastasis: A Dosimetric Analysis
    MacEwan, I.
    Chou, B.
    Mifflin, R.
    Wroe, A.
    Bush, D. A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E675 - E676
  • [10] Dosimetric analysis of liver toxicity after liver metastasis stereotactic body radiation therapy
    Barry, Aisling
    McPartlin, Andrew
    Lindsay, Patricia
    Wang, Lisa
    Brierley, James
    Kim, John
    Ringash, Jolie
    Wong, Rebecca
    Dinniwell, Rob
    Craig, Tim
    Dawson, Laura A.
    [J]. PRACTICAL RADIATION ONCOLOGY, 2017, 7 (05) : E331 - E337