Staff dosimetry protocols in interventional radiology

被引:40
|
作者
Padovani, R [1 ]
Foti, C [1 ]
Malisan, MR [1 ]
机构
[1] Osped S Maria Misericordia, Serv Fis Sanitaria, I-33100 Udine, Italy
关键词
D O I
10.1093/oxfordjournals.rpd.a006471
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Assessment of effective dose (E) for workers performing interventional radiology is particularly problematic due to the conditions of partial body exposure, so very few estimates of E are found in the literature. Two simple algorithms (the Rosenstein-Webster and the Niklason algorithms) are available that combine the readings of two dosemeters, one worn under the protective apron and one on the neck outside the apron, to estimate E for the range of imaging conditions typical of medical fluoroscopy. The algorithms are reviewed and their suitability for estimating E for personnel performing interventional radiology is analysed by comparison with the most recent experimental data. It can be concluded that the Niklason algorithm's estimates are in better agreement with the experimental assessments of E.
引用
收藏
页码:193 / 196
页数:4
相关论文
共 50 条
  • [1] Staff dosimetry protocols in interventional radiology
    Padovani, R
    Foti, C
    Malisan, MR
    DOSE AND IMAGE QUALITY IN DIGITAL IMAGING AND INTERVENTIONAL RADIOLOGY (DIMOND), 2001, : 193 - 196
  • [2] Patient dosimetry protocols in digital and interventional radiology
    Toivonen, H
    RADIATION PROTECTION DOSIMETRY, 2001, 94 (1-2) : 105 - 108
  • [3] Patient and staff dosimetry problems in interventional radiology
    Tsapaki, V
    DOSE AND IMAGE QUALITY IN DIGITAL IMAGING AND INTERVENTIONAL RADIOLOGY (DIMOND), 2001, : 113 - 116
  • [4] Patient and staff dosimetry problems in interventional radiology
    Tsapaki, V
    RADIATION PROTECTION DOSIMETRY, 2001, 94 (1-2) : 113 - 116
  • [5] Patient dosimetry protocols in digital and interventional radiology
    Toivonen, M
    DOSE AND IMAGE QUALITY IN DIGITAL IMAGING AND INTERVENTIONAL RADIOLOGY (DIMOND), 2001, : 105 - 108
  • [6] A practical method for routine eye lens dosimetry of staff in interventional radiology
    Bergans, Niki
    Vandermaesen, Alexander
    Vanheule, Jeroen
    Bogaerts, Ria
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (15-16) : 1779 - 1784
  • [7] COMPARISON OF DOUBLE DOSIMETRY ALGORITHMS FOR ESTIMATING THE EFFECTIVE DOSE IN OCCUPATIONAL DOSIMETRY OF INTERVENTIONAL RADIOLOGY STAFF
    Jarvinen, H.
    Buls, N.
    Clerinx, P.
    Miljanic, S.
    Nikodemova, D.
    Ranogajec-Komor, M.
    Struelens, L.
    d'Errico, F.
    RADIATION PROTECTION DOSIMETRY, 2008, 131 (01) : 80 - 86
  • [8] Overview of double dosimetry procedures for the determination of the effective dose to the interventional radiology staff
    Jarvinen, H.
    Buls, N.
    Clerinx, P.
    Jansen, J.
    Miljanic, S.
    Nikodemova, D.
    Ranogajec-Komor, M.
    d'Errico, F.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 333 - 339
  • [9] EURADOS Working Group 12 studies in interventional radiology for medical staff dosimetry
    Ferrari, P.
    Bakhanova, E.
    Becker, F.
    Campani, L.
    Chumak, V
    Jansen, J.
    Jovanovic, Z.
    Khan, S.
    Krstic, D.
    Mariotti, F.
    O'Connor, U.
    Pierotti, L.
    Principi, S.
    Clairand, I
    Knezevic, Z.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2018, 41 (06):
  • [10] Interventional Radiology and the Dosimetry Conundrum
    Reynolds, Alyssa
    Botkin, Crystal
    Frye, Sarah
    Gadani, Sameer
    Muzaffar, Razi
    Osman, Medhat
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60