Radiometric calibration history of visible and near-infrared portable radiometers

被引:13
|
作者
Johnson, BC [1 ]
Brown, SW [1 ]
Yoon, HW [1 ]
机构
[1] NIST, Opt Technol Div, Gaithersburg, MD 20899 USA
关键词
D O I
10.1088/0026-1394/37/5/17
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The National Institute of Standards and Technology (NIST), with the support of the National Aeronautics and Space Administration (NASA), has built several transfer radiometers that are used in radiometric measurement comparisons to validate spectral-radiance levels assigned to integrating-sphere sources by the end user. The transfer radiometers are characterized and calibrated at the NIST, and function as direct links in the spectral radiance measurement chain. This paper presents a historical analysis of a calibration method that utilizes a broadband source. Previously observed discrepancies between two radiometers are reconciled as a result.
引用
收藏
页码:423 / 426
页数:4
相关论文
共 50 条
  • [2] Calibration of a visible and near-infrared portable transfer radiometer
    Biggar, SF
    [J]. METROLOGIA, 1998, 35 (04) : 701 - 706
  • [3] Radiometric and spectral characterization and comparison of the Antarctic Dome C and Sonoran Desert sites for the calibration and validation of visible and near-infrared radiometers
    Uprety, Sirish
    Cao, Changyong
    [J]. JOURNAL OF APPLIED REMOTE SENSING, 2012, 6
  • [4] Inter-Band Radiometric Comparison and Calibration of ASTER Visible and Near-Infrared Bands
    Obata, Kenta
    Tsuchida, Satoshi
    Iwao, Koki
    [J]. REMOTE SENSING, 2015, 7 (11): : 15140 - 15160
  • [5] Toward consistent radiometric calibration of the NOAA AVHRR visible and near-infrared data record
    Bhatt, Rajendra
    Doelling, David R.
    Scarino, Benjamin R.
    Gopalan, Arun
    Haney, Conor O.
    [J]. EARTH OBSERVING SYSTEMS XX, 2015, 9607
  • [6] Cross-Calibration between ASTER and MODIS Visible to Near-Infrared Bands for Improvement of ASTER Radiometric Calibration
    Obata, Kenta
    Tsuchida, Satoshi
    Yamamoto, Hirokazu
    Thome, Kurtis
    [J]. SENSORS, 2017, 17 (08)
  • [7] Portable visible and near-infrared spectrophotometer for triglyceride measurements
    Kobayashi, Takanori
    Kato, Yukiko Hakariya
    Tsukamoto, Megumi
    Ikuta, Kazuyoshi
    Sakudo, Akikazu
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE, 2009, 23 (01) : 75 - 79
  • [8] Method for Uncertainty Evaluation of Vicarious Calibration of Spaceborne Visible to Near Infrared Radiometers
    Arai, Kohei
    Hasbi, Wahyudi
    Syafrudin, A. Hadi
    Hakim, Patria Rachman
    Salaswati, Sartika
    Prasetyo, Lilik Budi
    Setiawan, Yudi
    [J]. INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2019, 10 (01) : 387 - 393
  • [10] Radiometric calibration of SeaWiFS in the near infrared
    Martiny, N
    Frouin, R
    Santer, R
    [J]. APPLIED OPTICS, 2005, 44 (36) : 7828 - 7844