Basic performance of unitized Compton scattering type polarimeter

被引:5
|
作者
Tomita, H
Sano, S
Sakurai, H
Noma, M
Gunji, S
Takase, E
机构
[1] Dept. of Physics, Yamagata University, Yamagata
关键词
D O I
10.1109/23.507097
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have been developing a Compton scattering type polarimeter which consists of nine unit counters to detect the polarization of hard X-rays from stellar objects such as the Crab Nebula. We constructed one unit counter which consists of one plastic scintillator(7x7x5cm(3)) and four phoswich scintillators(6.7x1.1x32.2cm(3)) made of NaI(Tl)+CsI(Na). The characteristics of the unit counter were measured in detail to determine the detection efficiency (20.3%) and the modulation factor (27.5%) at 53.4keV. The background spectrum of the unit counter in the laboratory is also measured. Based on the results, the background from the outside of the active collimator is reduced by 50.5% when used with the PSD. On the basis of these results, the performance of the planned polarimeter was estimated by computer simulations. The results showed that the polarimeter can detect the polarization of hard X-rays from the Crab Nebula at a MDP (Minimum Detectable Polarization) of 14.0% with a 3-hour balloon observation.
引用
收藏
页码:1527 / 1532
页数:6
相关论文
共 50 条
  • [1] Basic performance of unitized Compton scattering type polarimeter
    Tomita, H
    Sano, S
    Sakurai, H
    Noma, M
    Gunji, S
    Takase, E
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 243 - 247
  • [2] Improvement of the modulation factor for a Compton scattering type polarimeter using subdivided scintillators
    Gunji, S
    Kudo, E
    Sakurai, H
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 610 - 613
  • [3] Performance of prototype hard X-ray polarimeter utilizing Compton scattering
    Suzuki, T
    Gunji, S
    Nakajima, R
    Yamashita, Y
    Suzuki, K
    Sakurai, H
    Tokanai, F
    Takashima, K
    Kobayashi, Y
    Tamura, K
    Kishimoto, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (1A): : 274 - 278
  • [4] MONTE-CARLO CALCULATION OF MULTIPLE-SCATTERING IN A COMPTON POLARIMETER
    LICHTENBERG, W
    PRZYBYLSKI, A
    NUCLEAR INSTRUMENTS & METHODS, 1972, 98 (01): : 99 - +
  • [5] A SECTORED GE-COMPTON POLARIMETER FOR PARITY ASSIGNMENTS IN PHOTON SCATTERING EXPERIMENTS
    SCHLITT, B
    MAIER, U
    FRIEDRICHS, H
    ALBERS, S
    BAUSKE, I
    VONBRENTANO, P
    HEIL, RD
    HERZBERG, RD
    KNEISSL, U
    MARGRAF, J
    PITZ, HH
    WESSELBORG, C
    ZILGES, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 337 (2-3): : 416 - 426
  • [6] Design of a Compton Polarimeter for BEPC
    尚仁成
    邓景康
    宁传刚
    朱胜江
    晋青珍
    朱鹤年
    徐望
    闫永廉
    夏绍健
    TsinghuaScienceandTechnology, 1998, (04) : 1184 - 1187
  • [7] POLARISATION MEASUREMENT AT THE ILC WITH A COMPTON POLARIMETER
    Bartels, C.
    List, J.
    POLARIZED SOURCES, TARGETS AND POLARIMETRY, 2011, : 90 - 97
  • [8] PERSPECTIVES OF EXPERIMENTS WITH COMPTON POLARIMETER IN ASTROPHYSICS
    GORODINSKII, GM
    ERMOLAEV, BI
    ZAITSEV, SV
    KRUGLOV, EM
    KHMYLKO, VV
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1984, 48 (11): : 2090 - 2092
  • [9] Measuring the Neutrino Helicity with a Compton Polarimeter
    V. B. Brudanin
    V. G. Egorov
    I. V. Zhitnikov
    M. V. Shirchenko
    Yu. A. Shitov
    Physics of Particles and Nuclei Letters, 2019, 16 : 537 - 541
  • [10] Polarization reconstruction algorithm for a Compton polarimeter
    Vockert, M.
    Weber, G.
    Spillmann, U.
    Krings, T.
    Stoehlker, Th
    FAIRNESS 2017: FAIR NEXT GENERATION SCIENTISTS 2017, 2018, 1024