A geometric model analysis of conductive airways in expiratory flow limitation during artificial ventilation

被引:0
|
作者
Cevenini, G [1 ]
Bernardi, F [1 ]
Massai, MR [1 ]
Barbini, P [1 ]
机构
[1] Univ Siena, Dept Surg & Bioengn, I-53100 Siena, Italy
来源
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Expiratory flow limitation (EFL) was simulated in mechanical ventilation through a recently proposed tracheobronchial tree model which reproduces breathing mechanics in the time-domain using Weibel's symmetrical description of lung anatomy considered as 17 upper generations conducting air and seven deeper generations where gas exchange takes place. The model allows for flow turbulence, inertance and tissue viscoelasticity to be represented nonlinearly and distributed along the tracheobronchial tree in a lumped parameter description. An electric analogue of the simulator, consisting of a RLC ladder network, was numerically implemented by Matlab-Simulink software. Normal conditions and chronic obstructive pulmonary disease (COPD) were simulated by setting model parameters. An extra negative expiratory pressure (NEP) was introduced to detect EFL. The transmural pressures of conductive airways, their viscoelastic characteristics and their related distributions of transversal geometrical changes over the breathing cycle were evaluated. The results showed that during mechanical ventilation, large modifications in the elastic characteristics of the conductive airways explain EFL in simulated COPD. In particular, a marked expiratory reduction in medium bronchi diameter, up to 20-30% of their maximum value, and a progressive decrease in small bronchi diameter during expiration were observed. A remarkably lower reduction in medium bronchi diameter and almost constant behaviour of small bronchi diameter during expiration were found in the simulated healthy subject. Application of NEP confirmed the absence of EFL for normal cases whereas COPD was flow limited over most of expiration.
引用
下载
收藏
页码:135 / 144
页数:10
相关论文
共 50 条
  • [1] Expiratory Flow Limitation During Mechanical Ventilation
    Junhasavasdikul, Detajin
    Telias, Irene
    Grieco, Domenico Luca
    Chen, Lu
    Gutierrez, Cinta Millan
    Piraino, Thomas
    Brochard, Laurent
    CHEST, 2018, 154 (04) : 948 - 962
  • [2] DETECTION OF EXPIRATORY FLOW LIMITATION DURING MECHANICAL VENTILATION
    VALTA, P
    CORBEIL, C
    LAVOIE, A
    CAMPODONICO, R
    KOULOURIS, N
    CHASSE, M
    BRAIDY, J
    MILICEMILI, J
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (05) : 1311 - 1317
  • [3] Increased deadspace ventilation during exercise in a human model of expiratory flow limitation
    Kayser, B
    Aliverti, A
    Iandelli, I
    Misuri, G
    Duranti, R
    Gorini, M
    Pedotti, A
    Scano, G
    Yan, S
    Kelly, S
    Sliwinski, P
    Cala, S
    Macklem, PT
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A417 - A417
  • [4] EXPIRATORY FLOW LIMITATION IN LARGE AND SMALL AIRWAYS
    ROBINSON, DR
    CHAUDHARY, BA
    SPEIR, WA
    ARCHIVES OF INTERNAL MEDICINE, 1984, 144 (07) : 1457 - 1460
  • [5] Detection of expiratory flow limitation during experimental mechanical ventilation
    MP Vassiliou
    A Amygdalou
    C Koubaniou
    C Katsanos
    P Vassiliou
    I Lihros
    R Peslin
    P Behrakis
    Critical Care, 10 (Suppl 1):
  • [6] Detection of Expiratory Flow Limitation by Forced Oscillations during Noninvasive Ventilation
    Zannin, Emanuela
    Chakrabarti, Biswajit
    Govoni, Leonardo
    Pompilio, Pasquale P.
    Romano, Robert
    Calverley, Peter M. A.
    Dellaca, Raffaele L.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 200 (08) : 1063 - 1065
  • [7] Detection of expiratory flow limitation during mechanical ventilation: a simulation study
    Brighenti, C
    Barbini, P
    Gnudi, G
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3921 - 3924
  • [8] Artificial Intelligence Determination Of Expiratory Flow Limitation During Exercise In Adults
    Luu, Peter
    Petrics, Gregory
    Haverkamp, Hans
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (09) : 662 - 662
  • [9] Estimation of lower airway resistance in expiratory flow limitation during mechanical ventilation
    Barbini, P
    Cevenini, G
    Massai, MR
    MODELLING IN MEDICINE AND BIOLOGY VI, 2005, 8 : 37 - 46
  • [10] A Simulation Study of Expiratory Flow Limitation in Obstructive Patients during Mechanical Ventilation
    Paolo Barbini
    Chiara Brighenti
    Gianni Gnudi
    Annals of Biomedical Engineering, 2006, 34 : 1879 - 1889