Modelling the fire resistance of steel-to-timber dowelled connections loaded perpendicularly to the grain

被引:17
|
作者
Palma, Pedro [1 ]
Frangi, Andrea [2 ]
机构
[1] Empa Mat Sci & Technol, Struct Engn Res Lab, Ueberlandstr 129, CH-8600 Dubendorf, Switzerland
[2] Swiss Fed Inst Technol, Inst Baustat Konstrukt, Stefano Franscini Pl 5, CH-8093 Zurich, Switzerland
关键词
Timber; Fire; Connections; Simulations; Steel-to-timber connections; Fire resistance; PERFORMANCE; TESTS;
D O I
10.1016/j.firesaf.2017.12.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A framework to model timber connections a normal temperature and in fire, based on combined finite-element (FE) heat-transfer analyses and temperature-dependent Johansen-type load-carrying models, was developed and applied in a parametric study of previously tested beam-to-column steel-to-timber dowelled connections. Comparison with experimental results shows that the FE heat transfer models provide good estimates of measured temperatures and the load-carrying model gives good approximations of the load-carrying capacity at normal temperature (for dowel and embedment failures) and under standard fire exposure. For the degrees of utilisation expected in fire E-fi/R-20 approximate to 0.3, the developed models are able to predict the failure mode of each dowel and the expected load-carrying capacity. Simulation results showed a clear influence of the thickness of the side members on the fire resistance of the analysed connections. The influence of dowel spacing is not so clear, as it also depends on the dowel diameter. A smaller dowel diameter seems to slightly improve the fire resistance, namely for smaller degrees of utilisation or thinner side members, but compromises the load carrying capacity at normal temperature.
引用
收藏
页码:54 / 74
页数:21
相关论文
共 50 条
  • [1] Fire design of steel-to-timber dowelled connections
    Erchinger, Carsten
    Frangi, Andrea
    Fontana, Mario
    ENGINEERING STRUCTURES, 2010, 32 (02) : 580 - 589
  • [2] Behavior of dowelled and bolted steel-to-timber connections exposed to fire
    Audebert, M.
    Dhima, D.
    Taazount, M.
    Bouchair, A.
    ENGINEERING STRUCTURES, 2012, 39 : 116 - 125
  • [3] Numerical modelling of the fire resistance of double sheared steel-to-timber connections
    Szasz, Attila
    Hlavicka, Viktor
    Lubloy, Eva
    Biro, Andras
    JOURNAL OF BUILDING ENGINEERING, 2021, 37 (37):
  • [4] Fire tests of steel-to-timber connections with high fire resistance
    Dhima, Dhionis
    Audebert, Maxime
    Bouchair, Abdelhamid
    Pinoteau, Nicolas
    FIRE AND MATERIALS, 2023, 47 (01) : 120 - 138
  • [5] Mechanical Behavior and Modeling of Dowelled Steel-to-Timber Moment-Resisting Connections
    Xu, Bo-Han
    Bouchair, Abdelhamid
    Racher, Patrick
    JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (06)
  • [6] Load-bearing capacity of the steel-to-timber connections in fire temperature
    Domanski, Tomasz
    Kmiecik, Kamil
    64THSCIENTIFIC CONFERENCE OF THE COMMITTEE FOR CIVIL ENGINEERING OF THE POLISH ACADEMY OF SCIENCES AND THE SCIENCE COMMITTEE OF THE POLISH ASSOCIATION OF CIVIL ENGINEERS (PZITB) (KRYNICA 2018), 2019, 262
  • [7] Experimental fire analysis of steel-to-timber connections using dowels and nails
    Frangi, Andrea
    Erchinger, Carsten
    Fontana, Mario
    FIRE AND MATERIALS, 2010, 34 (01) : 1 - 19
  • [8] Thermomechanical Analysis of Steel-to-Timber Connections under Fire and the Material Density Effect
    Gomes, Carlos
    Fonseca, Elza M. M.
    Lopes, Hernani M.
    APPLIED SCIENCES-BASEL, 2022, 12 (20):
  • [9] Analytical modelling of cold-formed steel-to-timber connections with inclined screws
    Vella, Nathan
    Gardner, Leroy
    Buhagiar, Spiridione
    ENGINEERING STRUCTURES, 2021, 249
  • [10] Predicting the Fire Resistance of Wood–Steel–Wood Timber Connections
    Lei Peng
    George Hadjisophocleus
    Jim Mehaffey
    Mohammad Mohammad
    Fire Technology, 2011, 47 : 1101 - 1119