Treatment of refractory ascites with an automated low-flow ascites pump in patients with cirrhosis

被引:47
|
作者
Stirnimann, G. [1 ]
Berg, T. [2 ]
Spahr, L. [3 ]
Zeuzem, S. [4 ]
McPherson, S. [5 ]
Lammert, F. [6 ]
Storni, F. [7 ,8 ]
Banz, V. [7 ,8 ]
Babatz, J. [9 ]
Vargas, V. [10 ]
Geier, A. [11 ]
Stallmach, A. [12 ]
Engelmann, C. [2 ]
Trepte, C. [13 ]
Capel, J. [13 ]
De Gottardi, A. [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Inselspital, Univ Clin Visceral Surg & Med,Hepatol, Bern, Switzerland
[2] Univ Hosp Leipzig, Sect Hepatol, Dept Gastroenterol & Rheumatol, Leipzig, Germany
[3] Geneva Univ Hosp, Dept Med Specialties, Serv Gastroenterol, Geneva, Switzerland
[4] Univ Hosp, Dept Med, Frankfurt, Germany
[5] Newcastle Upon Tyne Hosp NHS Fdn Trust, Freeman Hosp, Liver Unit, Newcastle, Tyne & Wear, England
[6] Saarland Univ, Med Ctr, Dept Med 2, Homburg, Germany
[7] Bern Univ Hosp, Inselspital, Dept Visceral Surg & Med, Bern, Switzerland
[8] Univ Bern, Bern, Switzerland
[9] Univ Klinikum Carl Gustav Carus, Med Klin 1, Dresden, Germany
[10] Univ Autonoma Barcelona, Hosp Vall dHebron, CIBERehd, Liver Unit, Barcelona, Spain
[11] Univ Hosp Wurzburg, Dept Med 2, Div Hepatol, Wurzburg, Germany
[12] Univ Klinikum Jena, Klin Innere Med Gastroenterol Hepatol & Infektiol, Jena, Germany
[13] Sequana Med AG, Zurich, Switzerland
关键词
INTRAHEPATIC PORTOSYSTEMIC SHUNT; PARACENTESIS PLUS ALBUMIN; INDUCED CIRCULATORY DYSFUNCTION; TRIAL COMPARING ALBUMIN; MANAGEMENT;
D O I
10.1111/apt.14331
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Refractory ascites (RA) is a frequent complication of cirrhosis, requiring large volume paracentesis or placement of a transjugular intrahepatic portosystemic shunt (TIPSS). The automated low-flow ascites pump (alfapump, Sequana Medical AG, Zurich, Switzerland) is an innovative treatment option for patients with RA. Aim: To assess safety and efficacy of this treatment in patients with a contraindication to TIPSS. Methods: Fifty-six patients (43 males; mean age 62years) from centres in Germany, Switzerland, UK and Spain were included and followed for up to 24months. Complications, device deficiencies, paracentesis frequency and patient survival were recorded. Results: At the time of this analysis, 3 patients completed the 24-month observation period, monitoring of 3 was ongoing, 9 underwent liver transplantation, 17 patients were withdrawn due to serious adverse events and 23 patients died. Most frequently observed technical complication was blocking of the peritoneal catheter. Twenty-three pump-related reinterventions (17 patients) and 12 pump exchanges (11 patients) were required during follow-up. The pump system was explanted in 48% of patients (in 17 patients due to serious adverse events, in 9 at the time of liver transplantation and in 1 due to recovery from RA). Median frequency of paracentesis dropped from 2.17 to 0.17 per month. Conclusions: The alfapump can expand therapeutic options for cirrhotic patients with RA. Continuous drainage of ascites in a closed loop automated system led to significant reduction in paracentesis frequency. Technical and procedural improvements are required to reduce the rate of adverse events and reinterventions.
引用
收藏
页码:981 / 991
页数:11
相关论文
共 50 条
  • [1] Automated low-flow ascites pump for the treatment of cirrhotic patients with refractory ascites
    Stirnimann, Guido
    Banz, Vanessa
    Storni, Federico
    De Gottardi, Andrea
    THERAPEUTIC ADVANCES IN GASTROENTEROLOGY, 2017, 10 (02) : 283 - 292
  • [2] Treatment of refractory ascites with the automated low-flow ascites pump: analysis of the surveillance database
    Stirnimann, Guido
    Berg, Thomas
    Spahr, Laurent
    Zeuzem, Stefan
    McPherson, Stuart
    Lammert, Frank
    Storni, Federico
    Banz, Vanessa
    Babatz, Jana
    Vargas, Victor
    Geier, Andreas
    Stallmach, Andreas
    Engelmann, Cornelius
    Trepte, Claudia
    Inhaber, Neil
    De Gottardi, Andrea
    HEPATOLOGY, 2016, 64 : 1034A - 1034A
  • [3] DESCRIPTION OF AN AUTOMATED LOW-FLOW ASCITES (ALFA) PUMP SYSTEM FOR THE TREATMENT OF REFRACTORY ASCITES IN PATIENTS WITH CIRRHOSIS. PRELIMINARY REPORT
    Bellot, P.
    Welker, M.
    Soriano, G.
    von Schaewen, M.
    Appenrodt, B.
    Weist, R.
    Tzonev, R.
    Handshiev, S.
    Verslype, C.
    Zeuzem, S.
    Moench, C.
    Guarner, C.
    Schott, E.
    Sauerbruch, T.
    Petrov, A.
    Katzarov, K.
    Nevens, F.
    Such, J.
    JOURNAL OF HEPATOLOGY, 2012, 56 : S23 - S23
  • [4] Systematic review with meta-analysis: automated low-flow ascites pump therapy for refractory ascites
    Lepida, Antonia
    Marot, Astrid
    Trepo, Eric
    Degre, Delphine
    Moreno, Christophe
    Deltenre, Pierre
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2019, 50 (09) : 978 - 987
  • [5] SAFETY AND EFFICACY OF AN AUTOMATED LOW FLOW ASCITES (ALFA) PUMP IN CIRRHOTIC PATIENTS WITH REFRACTORY ASCITES
    De Gottardi, A.
    Banz, V.
    Storni, F.
    Stirnimann, G.
    Semmo, N.
    Engelmann, C.
    Piguet, A. -C.
    Whittaker, S.
    Lammert, F.
    Berg, T.
    Zeuzem, S.
    Cordoba, J.
    Dufour, J. -F.
    JOURNAL OF HEPATOLOGY, 2014, 60 (01) : S244 - S244
  • [6] AN AUTOMATIC LOW FLOW ASCITES PUMP IMPROVES ASCITES CONTROL AND QUALITY OF LIFE IN PATIENTS WITH CIRRHOSIS AND RECURRENT ASCITES
    Wong, Florence
    Vargas, Hugo E.
    Reddy, K. Rajender
    Pagadala, Mangesh R.
    Rockey, Don C.
    Cheung, Angela
    Devuni, Deepika
    Wilder, Julius M.
    Saeian, Kia
    Leventhal, Thomas M.
    Asrani, Sumeet K.
    Pocha, Christine
    Sundaram, Vinay
    Bajaj, Jasmohan S.
    Capel, Jeroen
    Kamath, Patrick S.
    HEPATOLOGY, 2022, 76 : S1155 - S1156
  • [7] Automated low flow pump system for the treatment of refractory ascites: a single-center experience
    M. N. Thomas
    G. H. Sauter
    A. L. Gerbes
    M. Stangl
    T. S. Schiergens
    M. Angele
    J. Werner
    M. Guba
    Langenbeck's Archives of Surgery, 2015, 400 : 979 - 983
  • [8] Automated low flow pump system for the treatment of refractory ascites: a single-center experience
    Thomas, M. N.
    Sauter, G. H.
    Gerbes, A. L.
    Stangl, M.
    Schiergens, T. S.
    Angele, M.
    Werner, J.
    Guba, M.
    LANGENBECKS ARCHIVES OF SURGERY, 2015, 400 (08) : 979 - 983
  • [9] Treatment of refractory Ascites by Implantation of an automated Pump System
    Welker, M. -W.
    Ulrich, F.
    Zeuzem, S.
    GASTROENTEROLOGE, 2014, 9 (01): : 52 - 54
  • [10] Automated low-flow ascites pump in a real-world setting: complications and outcomes
    Solbach, Philipp
    zu Siederdissen, Christoph Honer
    Wellhoener, Freya
    Richter, Nicolas
    Heidrich, Benjamin
    Lenzen, Henrike
    Kerstin, Port
    Hueper, Katja
    Manns, Michael P.
    Wedemeyer, Heiner
    Jaeckel, Elmar
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2018, 30 (09) : 1082 - 1089