Radiation exposure to patients in lower limb trauma surgery

被引:0
|
作者
Malek, Sabur [1 ,2 ]
Davies, Eirian [3 ]
Malek, Ibrahim A. [4 ]
Rawal, Arvind [3 ]
Singh, Alok [3 ]
Harvey, Robert A. [3 ]
机构
[1] Univ Hull, Kingston Upon Hull HU6 7RX, N Humberside, England
[2] Hull Royal Infirm, Kingston Upon Hull HU3 2JZ, N Humberside, England
[3] Arrowe Pk Hosp, Wirral Hosp NHS Trust, Wirral, Merseyside, England
[4] Royal Liverpool Childrens NHS Trust, Liverpool, Merseyside, England
关键词
radiation exposure; dynamic hip screw; cannulated hip screw; intra medullary nailing; fracture femur;
D O I
10.1007/s00590-006-0126-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fluoroscopy equipments have enabled us to perform operations that otherwise would be impossible but only at the expense of exposing the patients and theatre staff to radiation. The aim of this study was to determine the average radiation exposure to the patients in dynamic hip screw (DHS) fixation, cannulated hip screw (CHS) fixation, intra-medullary nailing (IMN) of femur and tibia operations. The records of all patients undergoing the above operations between May 2000 and August 2003 were retrospectively reviewed. A total of 670 patients were included. 389 had DHS, 85 had CHS, 125 had IMN of femur and 71 had IMN of tibia operations. The average radiation time was 0.7, 1.1, 2.5 and 2.1 min and the average radiation dose (in dose area product-DAP) was 196, 356, 548 and 125 cGy cm 2 for DHS, CHS, IMN of femur and IMN of tibia, respectively. Compared to the registrars, radiation time and dose were higher with the consultants in DHS fixation (P = 0.02, 0.02). The radiation dose was higher with the senior house officers compared to the registrars in CHS fixation (P = 0.03). There were no significant differences between the consultants and the registrars in IM nailing operations. The study concludes that radiation exposure to the patients in DHS and CHS operations depends on the experience of the surgeon but not in IMN operations. The IMN of femur involved more than four times higher radiation than IMN of tibia and the CHS fixation involved double the radiation than the DHS fixation. The radiation time was poor comparative metric to estimate radiation dose.
引用
收藏
页码:17 / 21
页数:5
相关论文
共 50 条
  • [1] Radiation Exposure in Trauma Patients
    Johari, Hamed Ghoddusi
    Eskandari, Shima
    [J]. AMERICAN SURGEON, 2012, 78 (11) : 1298 - 1299
  • [2] Radiation exposure in trauma patients
    Ott, Mickey
    McAlister, Jennifer
    VanderKolk, Wayne E.
    Goldsmith, Austin
    Mattice, Connie
    Davis, Alan T.
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 61 (03): : 607 - 609
  • [3] Radiation Exposure in Patients with Isolated Limb Trauma: Acceptable or Are We Imaging Too Much?
    Wheeler, James A.
    Weaver, Natasha
    Balogh, Zsolt J.
    Drobetz, Herwig
    Kovendy, Andrew
    Enninghorst, Natalie
    [J]. JOURNAL OF CLINICAL MEDICINE, 2020, 9 (11) : 1 - 9
  • [4] Radiation exposure in trauma patients - Discussion
    Kim, Patrick K.
    Ott, Mickey
    Miller, Sidney F.
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 61 (03): : 609 - 610
  • [5] Quantification of Radiation Exposure in Trauma Patients
    Wagner, Michel
    Vonk, Jonathon
    Wichman, Chris
    Hegde, Ashwin
    Oliveto, Jennifer
    [J]. CRITICAL CARE MEDICINE, 2013, 41 (12)
  • [6] DIAGNOSTIC RADIATION EXPOSURE IN TRAUMA PATIENTS
    FITZGERALD, RH
    REINES, HD
    WISE, J
    [J]. SOUTHERN MEDICAL JOURNAL, 1983, 76 (12) : 1511 - 1514
  • [7] DIAGNOSTIC RADIATION EXPOSURE IN TRAUMA PATIENTS
    REINES, HD
    FITZGERALD, R
    WISE, J
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1982, 22 (07): : 635 - 635
  • [8] Radiation exposure to surgeon and patient in intramedullary nailing of the lower limb
    Madan, S
    Blakeway, C
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (08): : 723 - 727
  • [9] Lower Limb Salvage in Trauma
    Ong, Yee Siang
    Levin, L. Scott
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2010, 125 (02) : 582 - 588
  • [10] Radiation exposure to patients in lower limb trauma surgeryExposition aux irradiations des opérés pour traumatisme des membres inférieurs
    Sabur Malek
    Eirian Davies
    Ibrahim A. Malek
    Arvind Rawal
    Alok Singh
    Robert A. Harvey
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2007, 17 (1) : 17 - 21