Versatile SAR-ADC for Biomedical Applications

被引:0
|
作者
Sotiere, J. [1 ]
Terosiet, M. [1 ]
De Roux, E. [1 ]
Von Chong, A. [1 ]
Kolbl, F. [1 ]
Histace, A. [1 ]
Romain, O. [1 ]
机构
[1] Univ Cergy Pontoise, Univ Paris Seine, ENSEA, Lab ETIS,CNRS,UMR8051, F-95000 Cergy, France
关键词
Analog-to-Digital Conversion; reconfigurability; CMOS implementation; biomedical;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a versatile SAR ADC targeting the acquisition of signals in biomedical applications. The converter is implemented in a CMOS AMS 0.35 mu m technology and powered with 3.3V. Its output bit-width can be varied from 4 to 8 bits. The device includes built-in programmable clock generator and voltage reference circuit. The sampling rate can be tuned up to 100kS/s in the 8-bit mode and with a maximal input range of 2.5V. All these parameters can be independently adjusted. This is an unique fully-configurable converter. The simulation results are reported and positioned with respect to the most recent designs.
引用
收藏
页码:9 / 12
页数:4
相关论文
共 50 条
  • [21] Mismatch suppression and noise reduction for SAR-ADC with Bayes estimation method
    Zhao Lei
    Zhang Xiaolin
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2020, 102 (02) : 379 - 388
  • [22] The Impact of SAR-ADC Mismatch on Quantized Massive MU-MIMO Systems
    Guichemerre, Jeremy
    Studer, Christoph
    FIFTY-SEVENTH ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS & COMPUTERS, IEEECONF, 2023, : 420 - 426
  • [23] A Bypass-Switching SAR ADC With a Dynamic Proximity Comparator for Biomedical Applications
    Wang, Tzu-Yun
    Li, Hao-Yu
    Ma, Zong-Yu
    Huang, Yang-Jing
    Peng, Sheng-Yu
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2018, 53 (06) : 1743 - 1754
  • [24] A Low Voltage, Energy Efficient Supply Boosted SAR ADC For Biomedical Applications
    Mesgarani, Ali
    Ay, Suat U.
    2011 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2011, : 401 - 404
  • [25] 利用Multisim实现SAR-ADC的原理仿真与设计
    张彪
    莘济豪
    梁文哲
    电子产品世界, 2019, 26 (01) : 62 - 66
  • [26] Analysis of the Effects of Single Fvent Transients on an SAR-ADC based on Charge Redistribution
    Lanot, Alisson J. C.
    Balen, Tiago R.
    2014 15TH LATIN AMERICAN TEST WORKSHOP - LATW, 2014,
  • [27] A Novel Approach in SAR-ADC for Variable Conversion Time Using Window Detector
    Hadis, Mohd Iqbal Mohd
    Mande, Sudhakar
    2017 INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING, COMMUNICATIONS AND INFORMATICS (ICACCI), 2017, : 2141 - 2146
  • [28] An Ultra Low Power 10-bit 1KS SAR-ADC for ECG Signal Recording Applications
    Chen, Chen
    Wang, Bo
    2016 CHINA SEMICONDUCTOR TECHNOLOGY INTERNATIONAL CONFERENCE (CSTIC), 2016,
  • [29] Design Of Sar-Adc Based Mixed Signal Architecture For Low Power Application
    Thirrunavukkarasu, R. R.
    Kirthika, S.
    Nivetha, N.
    Renuka, N.
    2019 5TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING & COMMUNICATION SYSTEMS (ICACCS), 2019, : 822 - 824
  • [30] 基于SAR-ADC的精密同步数据采集系统设计
    王炳文
    微型机与应用, 2017, 36 (07) : 29 - 31+34