Versatile SAR-ADC for Biomedical Applications

被引:0
|
作者
Sotiere, J. [1 ]
Terosiet, M. [1 ]
De Roux, E. [1 ]
Von Chong, A. [1 ]
Kolbl, F. [1 ]
Histace, A. [1 ]
Romain, O. [1 ]
机构
[1] Univ Cergy Pontoise, Univ Paris Seine, ENSEA, Lab ETIS,CNRS,UMR8051, F-95000 Cergy, France
关键词
Analog-to-Digital Conversion; reconfigurability; CMOS implementation; biomedical;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a versatile SAR ADC targeting the acquisition of signals in biomedical applications. The converter is implemented in a CMOS AMS 0.35 mu m technology and powered with 3.3V. Its output bit-width can be varied from 4 to 8 bits. The device includes built-in programmable clock generator and voltage reference circuit. The sampling rate can be tuned up to 100kS/s in the 8-bit mode and with a maximal input range of 2.5V. All these parameters can be independently adjusted. This is an unique fully-configurable converter. The simulation results are reported and positioned with respect to the most recent designs.
引用
收藏
页码:9 / 12
页数:4
相关论文
共 50 条
  • [1] A Moving Binary Search SAR-ADC for Low Power Biomedical Data Acquisition System
    Liew, Wen-Sin
    Yao, Libin
    Lian, Yong
    2008 IEEE ASIA PACIFIC CONFERENCE ON CIRCUITS AND SYSTEMS (APCCAS 2008), VOLS 1-4, 2008, : 646 - 649
  • [2] External components improve SAR-ADC accuracy
    Baker, Bonnie C.
    Oljaca, Miro
    EDN, 2007, 52 (12) : 67 - +
  • [3] An Efficient Approach to Design a Comparator for SAR-ADC
    Singh, Tejender
    Tripathi, Suman Lata
    PROCEEDINGS OF 3RD IEEE CONFERENCE ON VLSI DEVICE, CIRCUIT AND SYSTEM (IEEE VLSI DCS 2022), 2022, : 116 - 122
  • [4] A Programmable ΔΣ SAR-ADC with Charge Shuttling Technique
    Yamada, Koller
    Toyama, Yosuke
    Ishikuro, Hiroki
    2016 INTERNATIONAL SOC DESIGN CONFERENCE (ISOCC), 2016, : 51 - 52
  • [5] External components improve SAR-ADC accuracy
    Texas Instruments, United States
    EDN, 2007, 12 (67-72)
  • [6] Design of Resource Sharing Reconfigurable ΔΣ SAR-ADC
    Ishizuka, Motomi
    Yamada, Kohei
    Ishikuro, Hiroki
    2018 23RD ASIA AND SOUTH PACIFIC DESIGN AUTOMATION CONFERENCE (ASP-DAC), 2018, : 317 - 318
  • [7] Rail to Rail Comparator for SAR ADC in Biomedical Applications
    ALjehani, Nawaf
    Abbas, Mohamed
    PROCEEDINGS OF THE 28TH INTERNATIONAL CONFERENCE MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS (MIXDES 2021), 2021, : 137 - 140
  • [8] An Offset Calibration Technique in a SAR ADC for Biomedical Applications
    Liu, Zhaozhe
    Wang, Wensi
    Wan, Peiyuan
    Geng, Jiarong
    Chen, Zhijie
    PROCEEDINGS OF 2018 12TH IEEE INTERNATIONAL CONFERENCE ON ANTI-COUNTERFEITING, SECURITY, AND IDENTIFICATION (ASID), 2018, : 217 - 220
  • [9] ANALYSIS OF POWER CONSUMPTION SAR-ADC DYNAMIC COMPARATOR
    Rusli, Julie R.
    Salleh, Noor Shelida
    Isa, Masnita M.
    Tan, K. Y.
    Shafie, Suhaidi
    JURNAL TEKNOLOGI, 2016, 78 (5-9): : 1 - 6
  • [10] Design of 8-bit SAR-ADC CMOS
    Hassan, Hur A.
    Halin, Izhal Abdul
    Bin Aris, Ishak
    Bin Hassan, Mohd Khair
    2009 IEEE STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT: SCORED 2009, PROCEEDINGS, 2009, : 272 - 275