Robot-Assisted Versus Fluoroscopy-Assisted Cortical Bone Trajectory Screw Instrumentation in Lumbar Spinal Surgery: A Matched-Cohort Comparison

被引:91
|
作者
Le, Xiaofeng [1 ]
Tian, Wei [1 ]
Shi, Zhan [1 ]
Han, Xiaoguang [1 ]
Liu, Yajun [1 ]
Liu, Bo [1 ]
He, Da [1 ]
Yuan, Qiang [1 ]
Sun, Yuqing [1 ]
Xu, Yunfeng [1 ]
机构
[1] Beijing Jishuitan Hosp, Dept Spine Surg, Beijing, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
Computer-assisted surgery; Cortical bone trajectory; Robotic surgery; Spine instrumentation; PEDICLE SCREW; INTERBODY FUSION; FIXATION; PLACEMENT; ACCURACY; SEGMENT;
D O I
10.1016/j.wneu.2018.08.157
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: The aim of the present study was to compare the accuracy and safety of TiRobot system-assisted with those of fluoroscopy-assisted cortical bone trajectory screw placement in lumbar spinal surgery. METHODS: We included 58 patients who required instrumentation in a retrospective matched-cohort study. The primary outcome measures were the accuracy of screw placement using the modified Gertzbein-Robbins scale and the incidence of proximal facet joint violation. Secondary outcome measures included operative time, intraoperative blood loss, postoperative hospital stay, radiation exposure, and complications. RESULTS: A total of 231 screws were placed (TiRobot group [RG], 86 screws; fluoroscopy group [FG], 145 screws). In the RG, 87.2% of the screws had perfect positions (grade A). The remaining screws were grade B (8.1%) and C (4.7%). In the FG, 66.9% of the screws had perfect positions (grade A). The remaining screws were grade B (20.0%), C (9.0%), and D (4.1%). The proportion of clinically acceptable screws (grade A or B) was greater in the RG than in the FG. In the RG, the most common direction of screw deviation was cephalad endplate and was the vertebral cortex in FG. No difference was found in facet joint violation between the 2 groups. The operative time and blood loss were slightly greater in the RG than in the FG. No statistically significant difference was found in the postoperative hospital stay between the 2 groups. The mean cumulative radiation time was greater for the RG than for the FG, but the radiation exposure to the surgeon was significantly lower in the RG than in the FG. CONCLUSIONS: Robot-assisted screw placement is more accurate and safe compared with fluoroscopy-assisted placement for lumbar spinal cortical bone trajectory instrumentation.
引用
收藏
页码:E745 / E751
页数:7
相关论文
共 50 条
  • [1] Effectiveness and safety of robot-assisted versus fluoroscopy-assisted cortical bone trajectory screw instrumentation in spinal surgery: a systematic review and meta-analysis
    Wang, Xu
    Li, Hao-xuan
    Zhu, Qing-san
    Zhu, Yu-hang
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [2] Accuracy and safety of robot-assisted cortical bone trajectory screw placement: a comparison of robot-assisted technique with fluoroscopy-assisted approach
    Li, Yue
    Chen, Long
    Liu, Yuzeng
    Ding, Hongtao
    Lu, Hongyi
    Pan, Aixing
    Zhang, Xinuo
    Hai, Yong
    Guan, Li
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [3] Accuracy and safety of robot-assisted cortical bone trajectory screw placement: a comparison of robot-assisted technique with fluoroscopy-assisted approach
    Yue Li
    Long Chen
    Yuzeng Liu
    Hongtao Ding
    Hongyi Lu
    Aixing Pan
    Xinuo Zhang
    Yong Hai
    Li Guan
    BMC Musculoskeletal Disorders, 23
  • [4] Comparison of robot versus fluoroscopy-assisted pedicle screw instrumentation in adolescent idiopathic scoliosis surgery: A retrospective study
    Hou, Canglong
    Yang, Huan
    Chen, Yu
    Yang, Yilin
    Zhang, Beichen
    Chen, Kai
    Li, Ming
    Yang, Mingyuan
    Chen, Kai
    FRONTIERS IN SURGERY, 2023, 9
  • [5] Safety and accuracy of robot-assisted versus fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery: a prospective randomized controlled trial
    Han, Xiaoguang
    Tian, Wei
    Liu, Yajun
    Liu, Bo
    He, Da
    Sun, Yuqing
    Han, Xiao
    Fan, Mingxing
    Zhao, Jingwei
    Xu, Yunfeng
    Zhang, Qi
    JOURNAL OF NEUROSURGERY-SPINE, 2019, 30 (05) : 615 - 622
  • [6] Comparison of robot versus fluoroscopy-assisted pedicle screw instrumentation in adolescent idiopathic scoliosis surgery: a Meta-analysis
    Kang, Yifan
    Wei, Lindong
    Liu, Jianrong
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [7] Is there a truly significant reduction in blood loss comparing robot-assisted versus fluoroscopy-assisted pedicle screw implantation in scoliosis surgery?
    Romeiro, Pedro Henrique Carvalho Leite
    Silva, Catarina Rodriguez
    Romeiro, Gabriel Henrique Carvalho Leite
    Bertani, Raphael
    NEUROSURGICAL REVIEW, 2024, 47 (01)
  • [8] Safety and accuracy of robot-assisted versus fluoroscopy-guided pedicle screw insertion for degenerative diseases of the lumbar spine: a matched cohort comparison
    Schatlo, Bawarjan
    Molliqaj, Granit
    Cuvinciuc, Victor
    Kotowski, Marc
    Schaller, Karl
    Tessitore, Enrico
    JOURNAL OF NEUROSURGERY-SPINE, 2014, 20 (06) : 636 - 643
  • [9] Comparison of Robot-Assisted and Fluoroscopy-Assisted Percutaneous Kyphoplasty for Bone Cement Distribution and Clinical Efficacy
    Tao, Hui
    Huang, Zhiwei
    Shao, Shanzhong
    Yang, Ruoyu
    Yang, Kun
    Zhang, Yinshun
    Li, Wei
    Dong, Fulong
    Qian, Jun
    Shen, Cailiang
    PAIN PHYSICIAN, 2024, 27 (08)
  • [10] Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery
    Molliqaj, Granit
    Schatlo, Bawarjan
    Alaid, Awad
    Solomiichuk, Volodymyr
    Rohde, Veit
    Schaller, Karl
    Tessitore, Enrico
    NEUROSURGICAL FOCUS, 2017, 42 (05)