Quantitative accuracy of CT numbers: Theoretical analyses and experimental studies

被引:17
|
作者
Zhang, Ran [1 ]
Cruz-Bastida, Juan P. [1 ]
Gomez-Cardona, Daniel [1 ]
Hayes, John W. [1 ]
Li, Ke [1 ,2 ]
Chen, Guang-Hong [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Sch Med & Publ Hlth, 1111 Highland Ave, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Radiol, Sch Med & Publ Hlth, 600 Highland Ave, Madison, WI 53792 USA
关键词
low-dose CT; photon-counting detector; reconstruction bias; RADIATION-DOSE REDUCTION; RAY COMPUTED-TOMOGRAPHY; TUBE CURRENT MODULATION; NOISE-POWER SPECTRUM; ITERATIVE RECONSTRUCTION; IMAGE-RECONSTRUCTION; ALGORITHMS; PHANTOM; MTF;
D O I
10.1002/mp.13119
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The CT number accuracy, that is, CT number bias, plays an important role in clinical diagnosis. When strategies to reduce radiation dose are discussed, it is important to make sure that the CT number bias is controlled within an acceptable range. The purpose of this paper was to investigate the dependence of CT number bias on radiation dose level and on image contrast (i.e., the difference in CT number between the ROI and the background) in Computed Tomography (CT). Methods: A lesion-background model was introduced to theoretically study how the CT number bias changes with radiation exposure level and with CT number contrast when a simple linear reconstruction algorithm such as filtered backprojection (FBP) is used. The theoretical results were validated with experimental studies using a benchtop CT system equipped with a photon-counting detector (XC-HYDRA FX50, XCounter AB, Sweden) and a clinical diagnostic MDCT scanner (Discovery CT750 HD, GE Healthcare, Waukesha, WI, USA) equipped with an energy-integrating detector. The Catphan phantom (Catphan 600, the Phantom Laboratory, Salem, NY, USA) was scanned at different mAs levels and 50 scans were performed for each mAs. The bias of CT number was evaluated for each combination of mAs and R011s with different contrast levels. An anthropomorphic phantom (ATOM 10-year-old phantom, Model 706, CMS Inc. Norfolk, VA, USA) with much more heterogeneous object content was used to test the applicability of the theory to the more general image object cases. Results: Both theoretical and experimental studies showed that the CT number bias is inversely proportional to the radiation exposure level yet linearly dependent on the CT number contrast between the lesion and the background, that is, Bias((mu) over cap (FBP)(1)) - alpha/mAs (1 + beta Delta IIU). Conclusions: The quantitative accuracy of CT numbers can he problematic and thus needs some extra attention when radiation dose is reduced. In this work, we showed that the bias of the FBP reconstruction increases as mAs is reduced; both positive and negative bias can he observed depending on the contrast difference between a targeted ROI and its surrounding background tissues. 2018 American Association of Physicists in Medicine
引用
收藏
页码:4519 / 4528
页数:10
相关论文
共 50 条
  • [1] QUANTITATIVE AND THEORETICAL ANALYSES OF AN EXPERIMENTAL HELICAL VORTEX
    ROTHFUSZ, LP
    LILLY, DK
    JOURNAL OF THE ATMOSPHERIC SCIENCES, 1989, 46 (14) : 2265 - 2279
  • [2] Impact of noise reduction schemes on quantitative accuracy of CT numbers
    Cruz-Bastida, Juan P.
    Zhang, Ran
    Gomez-Cardona, Daniel
    Hayes, John
    Li, Ke
    Chen, Guang-Hong
    MEDICAL PHYSICS, 2019, 46 (07) : 3013 - 3024
  • [3] Diverse structural assemblies of a series of ninhydrin derivatives: Quantitative analyses from experimental and theoretical studies
    Saini, Yeshwinder
    Mahajan, Sheena
    Kapoor, Kamal K.
    Hundal, Geeta
    Seth, Saikat Kumar
    JOURNAL OF MOLECULAR STRUCTURE, 2021, 1224
  • [4] Theoretical analyses and experimental studies on semiconductor disk lasers
    Song, Yanrong
    Zhang, Peng
    Zhang, Xinping
    Zhang, Zhigang
    OPTICAL AND QUANTUM ELECTRONICS, 2009, 41 (01) : 39 - 45
  • [5] Theoretical analyses and experimental studies on semiconductor disk lasers
    Yanrong Song
    Peng Zhang
    Xinping Zhang
    Zhigang Zhang
    Optical and Quantum Electronics, 2009, 41 : 39 - 45
  • [6] QUANTITATIVE CT SCAN STUDIES IN APHASIA .1. INFARCT SIZE AND CT NUMBERS
    NAESER, MA
    HAYWARD, RW
    LAUGHLIN, SA
    ZATZ, LM
    BRAIN AND LANGUAGE, 1981, 12 (01) : 140 - 164
  • [7] TOF reconstruction for improved quantitative accuracy in PET/CT studies with misalignment
    Bai, Chuanyong
    Andreyev, Andriy
    Hu, Zhiqiang
    Maniawski, Piotr
    Zhang, Jun
    Knopp, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [8] An evolutionary niche for quantitative theoretical analyses?
    Roudi, Y
    Treves, A
    BEHAVIORAL AND BRAIN SCIENCES, 2006, 29 (01) : 23 - +
  • [9] QUANTITATIVE ASSESSMENT OF HEPATIC HEAMODYNAMICS USING CT: ACCURACY AND PRECISION STUDIES IN PIGS
    Winterdahl, M.
    Sorensen, M.
    Mortensen, F. V.
    Alstrup, A. K. O.
    Hansen, S. B.
    Keiding, S.
    Munk, O. L.
    JOURNAL OF HEPATOLOGY, 2009, 50 : S283 - S283
  • [10] Quantitative Accuracy in Cardiac Studies with the GE Discovery RX PET/CT Scanner
    Spinks, T. J.
    Bastin, J. E.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2972 - 2976