Pulse transit time: validation of blood pressure measurement under positive airway pressure ventilation

被引:19
|
作者
Schmalgemeier, Heidi [1 ]
Bitter, Thomas [1 ]
Bartsch, Stephan [1 ]
Bullert, Kevin [1 ]
Fischbach, Thomas [1 ]
Eckert, Siegfried [1 ]
Horstkotte, Dieter [1 ]
Oldenburg, Olaf [1 ]
机构
[1] Ruhr Univ Bochum, Univ Hosp, Heart & Diabet Ctr N Rhine Westphalia, Dept Cardiol, D-32545 Bad Oeynhausen, Germany
关键词
Pulse transit time; Arterial blood pressure measurement; Continuous positive airway pressure (CPAP); Sleep disordered breathing; OBSTRUCTIVE SLEEP-APNEA; HEART-FAILURE; RISK; ECG;
D O I
10.1007/s11325-011-0609-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The objective of the present study was to validate noninvasive, continuous blood pressure (BP) measurement using pulse transit time (PTT) to represent absolute values and detect BP changes under continuous positive airway pressure (CPAP) treatment. We applied CPAP to 78 patients of a cardiological sleep lab using 0 (baseline), 4, 8, and 12 cmH(2)O for 10 min at every level and measured BP simultaneous via PTT-based method and standard oscillometric method (OM). Quality of signal perception was acceptable to convert PTT into BP values in 64 patients (82%). When comparing both methods, we found a strong linear correlation of systolic and diastolic BP (baseline, r = 0.94 for systolic BP; r = 0.95 for diastolic BP, p < 0.001) while no significant differences between absolute values obtained with OM and PTT measurement. Mean bias at baseline was 4.1 +/- 3.2 mmHg for systolic BP and 2.3 +/- 2.2 mmHg for diastolic BP. With increasing CPAP levels, PTT and OM measurements differed continuously up to a systolic difference of 6.6 +/- 4.9 mmHg and a diastolic difference of 4.4 +/- 3.5 mmHg. There was no definite trend of PTT method to either over- or underestimate BP. We found that PTT- and OM-based BP results are closely correlated while applying CPAP over a period of 40 min. With higher CPAP level, bias between both methods increased.
引用
收藏
页码:1105 / 1112
页数:8
相关论文
共 50 条
  • [1] Pulse transit time: validation of blood pressure measurement under positive airway pressure ventilation
    Heidi Schmalgemeier
    Thomas Bitter
    Stephan Bartsch
    Kevin Bullert
    Thomas Fischbach
    Siegfried Eckert
    Dieter Horstkotte
    Olaf Oldenburg
    Sleep and Breathing, 2012, 16 : 1105 - 1112
  • [2] PULSE TRANSIT TIME FOR BLOOD PRESSURE MEASUREMENT UNDER POSITIVE AIRWAY PRESSURE VENTILATION
    Schmalgemeier, Heidi
    Bitter, Thomas
    Bartsch, Stephan
    Bullert, Kevin
    Eckert, Siegfried
    Horstkotte, Dieter
    Oldenburg, Olaf
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E619 - E619
  • [3] Validation of Two Pulse Transit Time-Based Blood Pressure Measurement Devices
    Bard, Dylan M.
    Hahnen, Christina
    Joseph, Jeffrey I.
    van Helmond, Noud
    FASEB JOURNAL, 2019, 33
  • [4] Validation of ambulatory blood pressure monitoring and pulse transit time
    Liendo Martinez, K. H.
    Lopez-Padilla, D.
    De Miguel Diez, J.
    Villar Alvarez, F.
    Gomez Garcia, T.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [5] Continuous blood pressure measurement based on pulse transit time: a comparison to ambulatory blood pressure measurement
    Kuechler, G.
    Gehring, J.
    Wesely, M.
    Thimel, K.
    Haberl, R.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1267 - 1267
  • [6] Continuous Noninvasive blood pressure measurement by pulse transit time
    Fung, P
    Dumont, G
    Ries, C
    Mott, C
    Ansermino, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 738 - 741
  • [7] Validation of Pulse Transit Time-Based Blood pressure measurement in heart failure Patients with non-invasive Ventilation
    Spiesshoefer, J.
    Heinrich, J.
    Eckert, S.
    Bitter, T.
    Horstkotte, D.
    Oldenburg, O.
    INTERNIST, 2013, 54 : 106 - 106
  • [8] PULSE TRANSIT TIME CAN PREDICT THE HEMODYNAMIC EFFECTS OF POSITIVE PRESSURE VENTILATION
    Yamashita, K.
    Kawano, T.
    Yatabe, T.
    Abe, H.
    Yokoyama, M.
    ANESTHESIA AND ANALGESIA, 2012, 114
  • [9] VALIDATION OF THE FREESCAN PULSE TRANSIT TIME-BASED BLOOD PRESSURE MONITOR
    Wu, Chih-Cheng
    Chao, Paul C. -P.
    JOURNAL OF HYPERTENSION, 2016, 34 : E142 - E142
  • [10] Modeling of pulse transit time under the effects of hydrostatic pressure for cuffless blood pressure measurements
    Poon, Carmen C. Y.
    Zhang, Yuan-Ting
    Liu, Yinbo
    2006 3RD IEEE/EMBS INTERNATIONAL SUMMER SCHOOL ON MEDICAL DEVICES AND BIOSENSORS, 2006, : 65 - +