Quasi-static and pseudo-dynamic testing of infilled RC frames retrofitted with CFRP material

被引:27
|
作者
Ozkaynak, H. [1 ]
Yuksel, E. [1 ]
Buyukozturk, O. [2 ]
Yalcin, C. [3 ]
Dindar, A. A. [4 ]
机构
[1] Istanbul Tech Univ, Fac Civil Engn, TR-80626 Istanbul, Turkey
[2] MIT, Cambridge, MA 02139 USA
[3] Bogazici Univ, Dept Civil Engn, Istanbul, Turkey
[4] Istanbul Kultur Univ, Dept Civil Engn, Istanbul, Turkey
关键词
Carbon fiber; Plastic deformation; Strength; Retrofitting; MASONRY; WALLS;
D O I
10.1016/j.compositesb.2010.11.008
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The intact infill walls in reinforced concrete (RC) frames have beneficial effects to overall behavior in terms of stiffness, strength and energy dissipation in the event of seismic actions. The rationale of this paper is to increase effectiveness of the carbon fiber reinforced polymer (CFRP)-based retrofitting technique so that intact infill walls of vulnerable mid-rise RC buildings are transformed into a lateral load resisting system. The seismic behaviors of cross-braced and cross diamond-braced retrofitting schemes applied on infilled RC frames have been investigated experimentally. The research consisted of quasi-static (QS) tests where drift-based cyclic loading reversals were used and pseudo-dynamic (PsD) tests where acceleration intensity-based loading was used. Twelve 1/3-scaled RC frames were built and tested as bare and infilled control frames, and as cross-braced and cross diamond-braced retrofitted specimens. Significant findings were noted while comparing the QS and PsD tests. The maximum restoring force and drift couples that were obtained from PsD tests showed a close behavior pattern, regardless of the level of inertial masses, when compared with QS tests. The energy dissipation capacity of the specimens that was obtained from PsD test resulted somewhat less than the one tested with QS for the same level of damage. The performance of the retrofitted frames that was obtained from the experimental study was evaluated with code-specified performance limits. Accordingly, it was concluded that the cross diamond-bracing scheme is an effective retrofitting technique that brings the bare frame from collapse prevention (CP) to life safety (LS) performance levels. Finally, analytical predictions as per FEMA 356 guideline were performed and good agreement was obtained with experimental results. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:238 / 263
页数:26
相关论文
共 50 条
  • [1] Pseudo-Dynamic Testing and Analytical Modeling of AAC Infilled RC Frames
    Sucuoglu, Haluk
    Siddiqui, Umair A.
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2014, 18 (08) : 1281 - 1301
  • [2] PSEUDO-DYNAMIC TESTING OF REPAIRED AND RETROFITTED RC BRIDGES
    Lavorato, Davide
    Nuti, Camillo
    [J]. FIB SYMPOSIUM PRAGUE 2011: CONCRETE ENGINEERING FOR EXCELLENCE AND EFFICIENCY, VOLS 1 AND 2, 2011, : 451 - 454
  • [3] Quasi-Static Testing of RC Infilled Frames and Confined Stone-Concrete Bearing Walls
    Al-Nimry, Hanan S.
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2014, 18 (01) : 1 - 23
  • [4] Response of infilled frames using pseudo-dynamic experimentation
    Mosalam, KM
    White, RN
    Ayala, G
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1998, 27 (06): : 589 - 608
  • [5] Static response of infilled frames using quasi-static experimentation
    Mosalam, KM
    White, RN
    Gergely, P
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1997, 123 (11): : 1462 - 1469
  • [6] Pseudo-Dynamic and Quasi-Static Testing of an Irregular Steel Concrete Composite Frame with Wing Walls
    Bai, Yongtao
    Bai, Guoliang
    [J]. INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2016, 16 (02)
  • [7] Analytical Investigation of Lateral Strength of Masonry Infilled RC Frames Retrofitted with CFRP
    Erdem, Ibrahim
    Akyuz, Ugurhan
    [J]. JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2010, 24 (04) : 302 - 310
  • [8] Quasi-static cyclic testing of RC frames retrofitted using steel plate shear walls and diagonal tensile mesh
    Karimi R.
    TahamouliRoudsari M.
    [J]. Asian Journal of Civil Engineering, 2021, 22 (7) : 1301 - 1318
  • [9] Quasi-static cyclic and pseudo-dynamic tests on composite substructures with softening behaviour
    Bursi, OS
    Zandonini, R
    [J]. STABILITY AND DUCTILITY OF STEEL STRUCTURES, 1998, : 119 - 130
  • [10] Full scale pseudo-dynamic test for RC piers retrofitted with LRB
    Kwahk, Im-Jong
    Cho, Chang-Beck
    Han, Kyoung-Bong
    Kim, Young-Jin
    Kim, Byung-Suk
    [J]. IABSE Conference New Delhi, India 2005: ROLE OF STRUCTURAL ENGINEERS TOWARDS REDUCTION OF POVERTY, 2005, : 497 - 504