Evaluation of Two Novel Scale-Down Devices for Testing Monoclonal Antibody Aggregation During Large-Scale Freezing

被引:2
|
作者
Bluemel, Oliver [1 ]
Rodrigues, A. Miguel [2 ]
Buecheler, W. Jakob [3 ]
Geraldes, Vitor [4 ]
Hoelzl, Georg [5 ]
Hauptmann, Astrid [5 ]
Bechtold-Peters, Karoline [3 ]
Friess, Wolfgang [1 ]
机构
[1] Ludwig Maximilians Univ Muenchen, Dept Pharm, Pharmaceut Technol & Biopharmaceut, D-81377 Munich, Germany
[2] Inst Super Tecn, Ctr Quim Estrutural, Dept Chem Engn, P-1049001 Lisbon, Portugal
[3] Novartis Pharm AG, Tech Res & Dev, CH -4002 Basel, Switzerland
[4] Inst Super Tecn, Dept Chem Engn, CeFEMA, P-1049001 Lisbon, Portugal
[5] Sandoz GmbH, A-6336 Langkampfen, Austria
关键词
Aggregation; Freezing; Monoclonal antibody; Scale -down device; Thawing; PROTEIN AGGREGATION; STABILITY; PH;
D O I
10.1016/j.xphs.2022.01.003
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
There is a need for representative small volume devices that reflect monoclonal antibody (mAb) aggregation during freezing and thawing (FT) in large containers. We characterised two novel devices that aim to mimic the stress in rectangular 2 L bottles. The first scale-down device (SDD) consists of a 125 mL bottle surrounded by a 3D printed cover that manipulates heat exchange. The second device, a micro scale-down device (mSDD), adapts cooling and heating of 10 mL vials to extend stress time. MAb aggregation upon repeated FT was evaluated considering formation of higher molecular weight species, subvisible particles, and the increase in hydrodynamic radius, polydispersity index, and optical density at 350 nm. Three different mAb solutions were processed. Both an unshielded 125 mL bottle and the SDD can be used to predict aggregation during FT in 2 L bottles. In specific cases the unshielded 125 mL bottle underestimates whereas the SDD slightly overestimates soluble aggregate formation. The mSDD increases aggregation compared to 10 mL vials but is less representative than the SDD. Ultimately, both SDDs enable characterisation of protein sensi-tivity to large-scale FT with two orders of magnitude less volume and are superior to simply using smaller bottles.(c) 2022 American Pharmacists Association. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1973 / 1983
页数:11
相关论文
共 50 条
  • [1] Cryoconcentration and 3D Temperature Profiles During Freezing of mAb Solutions in Large-Scale PET Bottles and a Novel Scale-Down Device
    Bluemel, Oliver
    Buecheler, Jakob W.
    Rodrigues, Miguel A.
    Geraldes, Vitor
    Hoelzl, Georg
    Bechtold-Peters, Karoline
    Friess, Wolfgang
    [J]. PHARMACEUTICAL RESEARCH, 2020, 37 (09)
  • [2] Cryoconcentration and 3D Temperature Profiles During Freezing of mAb Solutions in Large-Scale PET Bottles and a Novel Scale-Down Device
    Oliver Bluemel
    Jakob W. Buecheler
    Miguel A. Rodrigues
    Vitor Geraldes
    Georg Hoelzl
    Karoline Bechtold-Peters
    Wolfgang Friess
    [J]. Pharmaceutical Research, 2020, 37
  • [3] Scale-down simulators for metabolic analysis of large-scale bioprocesses
    Neubauer, Peter
    Junne, Stefan
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 2010, 21 (01) : 114 - 121
  • [4] Scale-down model qualification methodology for a monoclonal antibody program
    Balasubramanian, Uma
    Easson, John
    Ghosh, Ayushman
    Maheshwari, Gargi
    Russo, Peter
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [5] Large-scale testing of the Internet's Border Gateway Protocol (BGP) via topological scale-down
    Carl, Glenn
    Kesidis, George
    [J]. ACM TRANSACTIONS ON MODELING AND COMPUTER SIMULATION, 2008, 18 (03):
  • [6] Development of a bioreactor scale-down model for a monoclonal antibody perfusion process
    Rex, Megan L.
    Magill, Al
    Goldberg, Ken
    Barnthouse, Kristopher
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [7] Scale-down model to simulate spatial pH variations in large-scale bioreactors
    Amanullah, A
    McFarlane, CM
    Emery, AN
    Nienow, AW
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2001, 73 (05) : 390 - 399
  • [8] Mimic of a Large-Scale Diafiltration Process by Using Ultra Scale-Down Rotating Disc Filter
    Ma, Guijun
    Aucamp, Jean
    Gerontas, Spyridon
    Eardley-Patel, Ranna
    Craig, Alan
    Hoare, Mike
    Zhou, Yuhong
    [J]. BIOTECHNOLOGY PROGRESS, 2010, 26 (02) : 466 - 476
  • [9] Modelling of the substrate heterogeneities experienced by a limited microbial population in scale-down and in large-scale bioreactors
    Delvigne, F.
    Lejeune, A.
    Destain, J.
    Thonart, P.
    [J]. CHEMICAL ENGINEERING JOURNAL, 2006, 120 (03) : 157 - 167
  • [10] Distribution of Protein Content and Number of Aggregates in Monoclonal Antibody Formulation After Large-Scale Freezing
    Astrid Hauptmann
    Georg Hoelzl
    Thomas Loerting
    [J]. AAPS PharmSciTech, 20