Solar radiation transfer and performance analysis of an optimum photovoltaic/thermal system

被引:126
|
作者
Zhao, Jiafei [1 ]
Song, Yongchen [1 ]
Lam, Wei-Haur [1 ]
Liu, Weiguo [1 ]
Liu, Yu [1 ]
Zhang, Yi [1 ]
Wang, DaYong [1 ]
机构
[1] Dalian Univ Technol, Minist Educ, Key Lab Ocean Energy Utilizat & Energy Conservat, Dalian 116024, Peoples R China
关键词
Photovoltaic/thermal; Direct absorption collector; Inverse method; Genetic algorithm; Exergy efficiency; THERMAL COLLECTOR; EXERGY ANALYSIS; HEATING SYSTEM; ENERGY; VALIDATION; SIMULATION; MODEL;
D O I
10.1016/j.enconman.2010.09.032
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents the design optimization of a photovoltaic/thermal (PV/T) system using both non-concentrated and concentrated solar radiation. The system consists of a photovoltaic (PV) module using silicon solar cell and a thermal unit based on the direct absorption collector (DAC) concept. First, the working fluid of the thermal unit absorbs the solar infrared radiation. Then, the remaining visible light is transmitted and converted into electricity by the solar cell. This arrangement prevents excessive heating of the solar cell which would otherwise negatively affects its electrical efficiency. The optical properties of the working fluid were modeled based on the damped oscillator Lorentz-Drude model satisfying the Kramers-Kronig relations. The coefficients of the model were retrieved by inverse method based on genetic algorithm, in order to (i) maximize transmission of solar radiation between 200 nm and 800 nm and (ii) maximize absorption in the infrared part of the spectrum from 800 nm to 2000 nm. The results indicate that the optimum system can effectively and separately use the visible and infrared part of solar radiation. The thermal unit absorbs 89% of the infrared radiation for photothermal conversion and transmits 84% of visible light to the solar cell for photoelectric conversion. When reducing the mass flow rate, the outflow temperature of the working fluid reaches 74 degrees C, the temperature of the PV module remains around 31 degrees C at a constant electrical efficiency about 9.6%. Furthermore, when the incident solar irradiance increases from 800 W/m(2) to 8000 W/m(2), the system generates 196 degrees C working fluid with constant thermal efficiency around 40%, and the exergetic efficiency increases from 12% to 22%. Crown Copyright (C) 2010 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1343 / 1353
页数:11
相关论文
共 50 条
  • [1] Solar radiation transfer and performance analysis for a low concentrating photovoltaic/thermal system
    Zhao, Jiafei
    Wang, Jiaqi
    Wang, Bin
    Liu, Jingwen
    Yang, Mingjun
    Jiang, Lanlan
    Zhang, Yi
    Song, Yongchen
    [J]. ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2016, 35 (01) : 263 - 270
  • [2] Analysis of the performance for a concentrating photovoltaic/thermal solar system
    Cheng, Xuetao
    Xu, Xianghua
    Liang, Xingang
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2009, 30 (05): : 624 - 627
  • [3] The performance analysis of the Trough Concentrating Solar Photovoltaic/Thermal system
    Li, M.
    Li, G. L.
    Ji, X.
    Yin, F.
    Xu, L.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (06) : 2378 - 2383
  • [4] Performance of photovoltaic/thermal solar system in building integrated photovoltaic
    Wei, Chenguang
    Bao, Yiwang
    Deng, Xiaoying
    Liu, Zhengquan
    Wu, Xiaoli
    [J]. Kuei Suan Jen Hsueh Pao/Journal of the Chinese Ceramic Society, 2013, 41 (02): : 149 - 152
  • [5] Analysis of a concentrating photovoltaic/thermal solar system
    Cheng, Xuetao
    Xu, Xianghua
    Liang, Xingang
    [J]. PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 1386 - 1390
  • [6] New Design of Solar Photovoltaic and Thermal Hybrid System for Performance Improvement of Solar Photovoltaic
    Hossain, Ridwone
    Ahmed, Al Jumlat
    Islam, Sheik Md Kazi Nazrul
    Saha, Nirupam
    Debnath, Preetom
    Kouzani, Abbas Z.
    Mahmud, M. A. Parvez
    [J]. INTERNATIONAL JOURNAL OF PHOTOENERGY, 2020, 2020 (2020)
  • [7] Performance analysis of the solar photovoltaic thermal system using phase change material
    Singh, Rahul
    Kumar, Anil
    Yadav, Anshul
    [J]. INTERNATIONAL CONFERENCE ON ADVANCES IN MATERIALS AND MANUFACTURING APPLICATIONS (ICONAMMA-2018), 2019, 577
  • [8] Description and performance analysis of a flexible photovoltaic/thermal (PV/T) solar system
    Gagliano, Antonio
    Tina, Giuseppe M.
    Nocera, Francesco
    Grasso, Alfio Dario
    Aneli, Stefano
    [J]. RENEWABLE ENERGY, 2019, 137 : 144 - 156
  • [9] Performance analysis of hybrid photovoltaic thermal solar system in Iraq climate condition
    Hamdoon, Omar Mohammed
    Alomar, Omar Rafae
    Salim, Badran Mohammed
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2020, 17
  • [10] Performance analysis of a concentrated photovoltaic and thermal system
    Ceylan, Ilhan
    Gurel, Ali Etem
    Ergun, Alper
    Tabak, Abdulsamed
    [J]. SOLAR ENERGY, 2016, 129 : 217 - 223